Range of combined bath filler and overflow waste assemblies incorporating a cable operated pop-up waste. The outlet incorporates a plastic flow straightener. Maximum operating temperature 60°C.
Spout outlet with brass body, incorporating aerator, available in different finishes. Maximum operating temperature 65°C.
In-line water filter system comprising of a head and replaceable carbon block cartridge (within a fixed housing) for use with John Guest LLDPE pipe. Maximum working pressure 8.6 bar. Cold water use only.
Range of solder ring copper fittings for use with copper tube to EN 1057. The 304756, 110804, 304574, 304615 & 304711 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of compression fittings with brass brass bodies for use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘KSO’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). The KSO14 sand KSO15 tap connector models incorporate an EPDM washer. Maximum working pressure 16.0 bar. Maximum working temperature 85˚C
Timco - Elysee range of Polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Jason range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of end feed copper fittings for use with copper tube to EN 1057. The 950513, 950514, 950501, 950503 & 950502 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Varipoint range of unvented water heaters with copper bodies, fitted with a temperature & pressure relief valve (7.0 bar) and supplied with a pressure relief valve (6.0 bar). Maximum working pressure 5.5 bar. Maximum operating temperature 85°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Brass fitting Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Biofilm and water quality monitor incorporating a stainless-steel body and silicon seals. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single and twin shower booster pumps with plastic bodies and impellers. The pump body inlet incorporates a combined EPDM washer and stainless steel strainer. Maximum working pressure: PL45 & PL45S models - 1.5 bar, PL65 & PL65S models - 2.0 bar. Maximum operating temperature 65°C.
Range of shower handsets with brass bodies, available with various finishes. The inlet incorporates a plastic regulator and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 80°C
Range of shower handsets with plastic bodies (chrome plated or white finish). Maximum operating temperature 60.0°C
Range of shower handsets and shower heads. The shower handsets have a plastic body (white), NBR ‘O’-rings, and a coloured locking ring around the shower face (see model section). The shower heads have a plastic body (white or chrome plated 02-093173 model), NBR ‘O’-rings, directional adjustment (ball joint) and a coloured interlocking ring either surrounding or central to the shower face (except for the 02-093165 and 02-093173 models which have no ring). The Wall shower T-L models have a combined NBR washer and stainless steel strainer on the inlet.
Page 228 of 554
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.