Directory Search Results

Print List

#250202006

Water meter manifold with a gunmetal body. The product incorporates a non-return valve (not suitable for backflow protection) and a spherical valve on the inlet. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1510 Water Meter Manifolds
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1" BSP (F) x 1” BSP (F).
Marking:
WATERFIT, Waterfit logo, flow arrow and size on body. CR on crutch head and cap.
Installation Requirements:
R001
Expiry date:
28/02/2030
Model:
SACAXX004038

Manufacturer:
Waterfit Ltd
Company Name
Waterfit Ltd
Address
PO Box 28 293 Birmingham New Road Dudley
Postcode
DY1 4SJ
Country
West Midlands
Phone
0121 5207987

View All Listings by this Company

Print This Approval


#250104714

Mixing valve incorporating a brass body and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure10.0 bar. Maximum operating temperature 65°C.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (F) captive nut
Marking:
Presto on body
Installation Requirements:
R001 R008 R010
Expiry date:
31/01/2030
Model:
29424 MIXER G1/2
Product Images

Manufacturer:
Les Robinets Presto S.A
Company Name
Les Robinets Presto S.A
Address
4 Rue Lavoiser St. Georges De Didonne
Postcode
17110
Country
France
Phone
+33 546 053 452

View All Listings by this Company

Print This Approval


#241002707

Range of pumps with plastic bodies, pistons and TPE diaphragm. For use with John Guest LLDPE pipe. The products incorporate non-return valves (not suitable for backflow protection). Maximum working pressure: 8.27 Bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241002707
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
5/16” push fitting.
Marking:
LEFOO, model number, production batch# and related technical parameters on body.
Installation Requirements:
R001 R415
Expiry date:
31/10/2029
Model:
LFP-ABC-D. Model code description:LFP-ABC-D LF means LEFOO, P means Pump A means voltage,0=12V,1=24V,2=36V,5=115V,6=230V B means flow rate,=050,075,100,150,200,300,400,500,600,800,1000 C means function,=W means stabilized;=S means self-priming) D means motor type;=A, B, P or Blank; A - Downgrade Brush motor, B - Brushless motor, Blank - Brush motor, P - Upgraded brush motor
Product Images

Manufacturer:
Lefoo Industrial Co., Ltd.
Company Name
Lefoo Industrial Co., Ltd.
Address
NO.118 Changda Road, Linping Street, Linping District, Hangzhou City, Zhejiang Province
Country
China

View All Listings by this Company

Print This Approval


#241002722

Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. 9Maximum operating temperature 80°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241002722
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
The discharge from the drain plug must be via a type `AA`, `AB` or `AD` airgap, or in accordance with EN1717.
Size:
P 3S & U 5S models: 1” BSP (F) inlet x 1” BSP (F) outlet. P 7S models: 1¼” BSP (F) inlet x 1” BSP (F) outlet. P 9S models: 1½” BSP (F) inlet x 1¼” BSP (F) outlet. P 18S models: 2” BSP (F) inlet x 1½” BSP (F) outlet.
Marking:
Foras (Brand of Pentax), model code and other technical information on data plate on body.
Installation Requirements:
R001 R415
Expiry date:
31/10/2029
Model:
P range: P X(S) - XX/Y (T) Where: P = pump model X = Nominal flow-rate m³/h (3, 5, 7, 9, 18 see model list), S = ULTRA S range - stainless steel hydraulic part, XX = nominal power HPx100 (50 - 400 see model list), Y = Number of impellers (2 - 7 see model list), T = 3 phase, [blank] = single phase. P 3S models: P 3S-50/2; P 3S-70/3; P 3S-90/4; P 3S-100/5; P 3S-120/6; P 3S-150/7. P 5S models: P 5S-70/2; P 5S-80/3; P 5S-120/4; P 5S-150/5; P 5S-180/6; P 5S-200/7. P 7S models: P 7S-100/2; P 7S-120/3; P 7S-180/4; P 7S-250/5; P 7S-300/6. P 9S models: P 9S-100/2; P 9S-150/3; P 9S-200/4; P 9S-250/5. P 3S models: P 3S-50/2 T; P 3S-70/3 T; P 3S-90/4 T; P 3S-100/5 T; P 3S-120/6 T; P 3S-150/7 T. P 5S models: P 5S-70/2 T; P 5S-80/3 T; P 5S-120/4 T; P 5S-150/5 T; P 5S-180/6 T; P 5S-200/7 T. P 7S models: P 7S-100/2 T; P 7S-120/3 T; P 7S-180/4 T; P 7S-250/5 T; P 7S-300/6 T; P 7S-350/7 T. P 9S models: P 9S-100/2 T; P 9S-150/3 T; P 9S-200/4 T; P 9S-250/5 T. P 18S models: P 18S-180/2 T; P 18S-250/3 T; P 18S-400/4 T.

Approval Holder:
PENTAX INDUSTRIES SpA
Company Name
PENTAX INDUSTRIES SpA
Address
Viale dell’Industria 1 Veronella
Postcode
37040
Country
Italy
Phone
+39 0442 489567
General Email
g.cengia@pentax-pumps.it

View All Listings by this Company

Print This Approval


#250102716

Range of booster pumps with stainless steel bodies, impellers and non-return valves (not suitable for backflow protection) at the inlets. From June 2025 the pumps are available with plastic or stainless steel impellers. Maximum working pressure 6.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250102716
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1” BSP (M).
Marking:
Pedrollo Spa logo on front panel. Model and product information on adhesive label.
Installation Requirements:
R001 R008 R415
Expiry date:
31/01/2030
Model:
DG-BLU 3, DG PED 3 EVO, DG-BLU 5, DG PED 5 EVO, DUAL DG-BLU 3+3, DUAL DG PED EVO 3+3, DUAL DG-BLU 3+5, DUAL DG PED EVO 3+5, DUAL DG-BLU 5+5, DUAL DG PED EVO 5+5.
Product Images

Manufacturer:
Pedrollo S.p.A.
Company Name
Pedrollo S.p.A.
Address
via Enrico Fermi, 7 37047 San Bonifacio (VR)
Country
Italy
Phone
+39 045 6136311

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2051 of 2264

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.