Directory Search Results

Print List

#2107159

Range of WC dual flush drop valve comprising of a plastic body, silicone seating washer and an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2107159
Size:
See models.
Marking:
Plumbright on the body. WRAS & Model code on body
Installation Requirements:
R001 R571
Expiry date:
31/07/2026
Model:
137004 PLUMBRIGHT: 1½” BSP (M),

Approval Holder:
The Highbourne Group, City Plumbing Supplies
Company Name
The Highbourne Group, City Plumbing Supplies
Address
Branch Support Centre Highbourne House Highbourne House Crick Northampton
Postcode
NN6 7SL
Country
United Kingdom
Phone
07342 078865
General Email
Lindsey.cocks-stevens@cityplumbing.co.uk

View All Listings by this Company

Print This Approval


#241202701

Range of WC single flush flapper valves with an ABS body. The valves are operated via a lever handle or a push button assembly and incorporate an internal overflow. Cold water use only

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
241202701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1½” BSP (M)
Marking:
Fluidmaster logo and patent number on flapper.
Installation Requirements:
R001 R571
Expiry date:
31/12/2029
Model:
507UKK071, 507UKK073, PRO71UK & PRO73UK
Product Images

Manufacturer:
Fluidmaster, Inc.
Company Name
Fluidmaster, Inc.
Address
30800 Rancho Viejo Road San Juan Capistrano
Postcode
CA 92675
Country
United States
Phone
1-949-796-2653

View All Listings by this Company

Print This Approval


#241202710

Range of near boiling hot water dispensers with stainless steel tanks and flow is controlled via float switch. Maximum working pressure 3 Bar. Maximum operating temperature 98°C.

Section:
1380 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, closed outlet. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within with system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
241202710
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
3/8” BSP M inlet/outlet
Marking:
New Lanbiao logo on label on front of body. Model and product info on label on rear of body.
Installation Requirements:
R001
Expiry date:
31/12/2029
Model:
51023, 51006, 51022-H, 51005-H, 51022-B, 51005-B
Product Images

Approval Holder:
Taizhou New Lanbiao Intelligent Technology Co.,Ltd
Company Name
Taizhou New Lanbiao Intelligent Technology Co.,Ltd
Address
JIAOXI INDUSTRIAL ZONE, QINGGANG, YUHUAN, TAIZHOU
Country
China

View All Listings by this Company

Print This Approval


#241202032

Range of inline water meters with brass bodies (blue or red epoxy coating). The inlet incorporates a plastic strainer. Maximum working pressure 16.0 Bar. Maximum operating temperature 85.0°C.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP (M) to 2 ½” BSP (M).
Marking:
B METERS logo, model code and other technical information on meter face. B METERS logo on dial cap. Flow arrow & size on body.
Installation Requirements:
R001
Expiry date:
31/12/2029
Model:
GMDM – Multi jet super dry water meter with glass window. GMDM-I – Multi jet super dry water meter with inductive 1 lt index for connection to external radio or mbus modules. GMDM-RFM – Multi jet super dray water meter with inductive 1 lt index for connection to external radio or mbus modules. GMDM-R – Multi jet super dry water meter with magnetic index, 1, 10, 100 or 1000 lt for connection with reed sensor pulse output.
Product Images

Manufacturer:
Bmeters S.r.l
Company Name
Bmeters S.r.l
Address
Via Friuli, 3 33050 Gonars (Udine) Italy

View All Listings by this Company

Print This Approval


#241204028

Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve. Models ending in ‘CGDM’ incorporate a single check valve cartridge and models ending in ‘CGDCVDM’ incorporate two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1510 Water Meter Manifolds
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP (F) & 2” BSP (F).
Marking:
Atplas logo on body.
Installation Requirements:
R001 R008
Expiry date:
31/12/2029
Model:
MB40403036CGDM Matrix. MB40403034CGDM Matrix. MB40408036CGDM Matrix. MB40408034CGDM Matrix. MB40408036CGDCVDM Matrix. MB40408034CGDCVDM Matrix.
Product Images

Approval Holder:
Atlantic Plastics Ltd.
Company Name
Atlantic Plastics Ltd.
Address
Coytraherne Close, Brackla, Bridgend
Postcode
CF31 2AX
Country
United Kingdom
Phone
01656672628
General Email
rhodgkiss@atplas.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2021 of 2221

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.