Heaters

Section Code 1465 : Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.

Back To Directory Sections

#2309044

Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system. The products can be supplied with a rigid or flexible filling loop or keyless filling link. The flexible and rigid filling loops incorporate a flexible hose or copper pipe, isolation valve, double check valve assembly (suitable for back flow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (suitable for back flow protection against fluid category 3). The products also incorporate an expansion vessel and pressure relief valve set at 3.0 bar. Maximum working pressure of primary circuit 2.5 bar. Maximum operating temperature of primary circuit 85°C Maximum working pressure of secondary circuit 8.0 bar Maximum operating temperature of secondary circuit 60°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2309044
Size:
¾” BSP (M) (primary circuit). ½” BSP (M) (secondary circuit).
Marking:
Baxi on front cover.
Installation Requirements:
R001 R140 R360
Expiry date:
30/09/2028
Model:
7796586 BAXI 624 COMBI 2 7796587 BAXI 630 COMBI 2 7796588 BAXI 636 COMBI 2 7813609 BAXI 624 COMBI LPG 2 7814304 BAXI 824 COMBI 2 7814305 BAXI 830 COMBI 2 7814306 BAXI 836 COMBI 2 7814307 BAXI 830 COMBI LPG 2 7814308 BAXI 836 COMBI LPG 2 7814309 BAXI ASSURE 524 COMBI 2 7814310 BAXI ASSURE 530 COMBI 2 7814311 BAXI ASSURE 536 COMBI 2 7814312 BAXI ASSURE 530 COMBI LPG 2

Approval Holder:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval


#2309313

‘SATK 32’ range of indirect heat interface units providing instantaneous hot water. Domestic hot water is provided via a plate heat exchanger and this circuit incorporates a flow detector, stainless-steel filter and water hammer arrestor. The primary/space heating circuit incorporates a pressure relief valve set at 2.5 bar and an expansion vessel. Maximum working pressure of the domestic hot water circuit is 10.0 bar. Maximum working pressure of the primary circuit is 16.0 bar. Maximum working pressure of the space heating circuit is 2.5 bar. Maximum operating temperature 90°C.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2309313
Size:
¾” BSP (M).
Marking:
Caleffi and Caleffi logo moulded on face of unit. Caleffi, Caleffi logo, model number and technical info on data plate inside unit.
Installation Requirements:
R001 R140 R360
Expiry date:
30/09/2028
Model:
SATK32103 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 50kW. SATK32105 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 60kW. SATK32107 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 75kW.
Product Images

Approval Holder:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company

Print This Approval


#2402803

Range of wall mounted, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel, pressure relief valve set at 3.0 bar and flow regulators. The inlets to both domestic hot water and primary circuits are controlled via screwdriver operated angled spherical valve. The primary circuit can be filled via a built in CAB device, that has been verified by test (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 80°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2402803
Size:
22mm Compression Primary 15mm Compression Secondary
Marking:
Worcester on label on the front panel. Serial number, model numbers and other technical information on adhesive labels on body and underside of the unit
Installation Requirements:
R001
Expiry date:
28/02/2029
Model:
Worcester Greenstar 8000 Style GR8700iW 30 C - Gas combi boiler 30kw, 14 plate heat exchanger 111/min, Worcester Greenstar 8000 Style GR8700iW 35 C - Gas combi boiler 35kw, 16 plate heat exchanger 131/min, Worcester Greenstar 8000 Style GR8700iW 40 C - Gas combi boiler 40kw, 18 plate heat exchanger 141/min, Worcester Greenstar 8000 Style GR8700iW 45 C - Gas combi boiler 45kw, 18 plate heat exchanger 151/min, Worcester Greenstar 8000 Style GR8700iW 50 C - Gas combi boiler 50kw, 20 plate heat exchanger 151/min. Worcester Greenstar 8000 Life GR8300iW 30 C - Gas combi boiler 30kw, 14 plate heat exchanger 111/min, Worcester Greenstar 8000 Life GR8300iW 35 C - Gas combi boiler 35kw, 16 plate heat exchanger 131/min, Worcester Greenstar 8000 Life GR8300iW 40 C - Gas combi boiler 40kw, 18 plate heat exchanger 141/min, Worcester Greenstar 8000 Life GR8300iW 45 C - Gas combi boiler 45kw, 18 plate heat exchanger 151/min, Worcester Greenstar 8000 Life GR8300iW 50 C - Gas combi boiler 50kw, 20 plate heat exchanger 151/min. Models added September 2024 Worcester Greenstar 8000+ GR8701iW 32 CB - Gas combi boiler 32kW, 16 plate heat exchanger 13 l/min Worcester Greenstar 8000+ GR8701iW 36 CB - Gas combi boiler 36kW, 16 plate heat exchanger 14 l/min Worcester Greenstar 8000+ GR8701iW 32 C - Gas combi boiler 32kW, 16 plate heat exchanger 13 l/min Worcester Greenstar 8000+ GR8701iW 36 C - Gas combi boiler 36kW, 16 plate heat exchanger 14 l/min Worcester Greenstar 8000+ GR8701iW 40 C - Gas combi boiler 40kW, 18 plate heat exchanger 15 l/min Worcester Greenstar 8000+ GR8701iW 45 C - Gas combi boiler 45kW, 18 plate heat exchanger 18 l/min Worcester Greenstar 8000+ GR8701iW 50 C - Gas combi boiler 50kW, 20 plate heat exchanger 21 l/min

Approval Holder:
Worcester Bosch
Company Name
Worcester Bosch
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
+44 1905 752761
General Email
ian.sharp@uk.bosch.com

View All Listings by this Company

Print This Approval


#240202716

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel filter. The primary and secondary circuit incorporates isolation valves on the flow and the primary also has one on the return. Maximum working pressures: Secondary DHW: 10.0 Bar Primary CH: 2.5 Bar Maximum operating temperatures: Secondary DHW: 65.0°C Primary CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240202716
Size:
DHW: 22mm compression. CH: 22mm compression
Marking:
Vaillant logo, serial number, CE, pressure and other technical information on adhesive label on bottom of unit
Installation Requirements:
R001 R140 R360
Expiry date:
28/02/2029
Model:
0010019980 – VUW 246/7-2 (H-GB) ecoTec sustain 24 0010019981 – VUW 286/7-2 (H-GB) ecoTec sustain 28 0010019982 – VUW 346/7-2 (H-GB) ecoTec sustain 34
Product Images

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company

Print This Approval


#240502715

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240502715
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DHW: 15mm compression. CH: 22mm compression
Marking:
Range name on front cover, Model, Max pressure, Max temperature and product information on data plate on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2029
Model:
Models without a filing loop supplied: 0010016113 - Glow-worm ESSENTIAL 24c -A (H-GB) 0010016115 - Glow-worm ESSENTIAL 28c -A (H-GB) 0010016127 - Heatline CAPRIZ 2 24c -A (H-GB) 0010016128 - Heatline MONZA 2 24c -A (H-GB) 0010016129 - Heatline CAPRIZ 2 28c -A (H-GB) 0010016130 - Heatline MONZA 2 28c -A (H-GB) 0010021401 - Glow-worm EASICOM 3 24c -A (H-GB) 0010021402 - Glow-worm EASICOM 3 28c -A (H-GB) 0010020392 - Vaillant VUW 256/6-3 (H-GB) ecoFIT sustain 825 0010020393 - Vaillant VUW 306/6-3 (H-GB) ecoFIT sustain 830 0010020394 - Vaillant VUW 356/6-3 (H-GB) ecoFITsustain 835 Models with a filling loop supplied: 0010020389 - Vaillant VUW 256/6-3 (H-GB) ecoFIT pure 825 0010020390 - Vaillant VUW 306/6-3 (H-GB) ecoFIT pure 830 0010020391 - Vaillant VUW 356/6-3 (H-GB) ecoFIT pure 835 0010019813 - Vaillant VUW 306/6-3 (P-GB) ecoFIT pure 830 P 0010021204 - Glow-worm BETACOM 4 24c -A (H-GB) 0010021205 - Glow-worm BETACOM 4 30c -A (H-GB) 0010021404 - Glow-worm ULTIMATE 3 30c -A (H-GB) 0010021405 - Glow-worm ULTIMATE 3 35c -A (H-GB) 0010027591 - Glow-worm ENERGY 2 30c -A (P-GB) 0010035896 - Glow-worm ENERGY 7 25c (H-GB) 0010035897 - Glow-worm ENERGY 7 30c (H-GB) 0010035898 - Glow-worm ENERGY 7 35c (H-GB)
Product Images

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company

Print This Approval


#240502720

Range of wall mounted combination boilers providing domestic hot water (DHW) via a plate heat exchanger and pressurised central heating (CH) system. Incorporating a pressure relief valve set at 3.0 bar and expansion vessel. Supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressure Primary circuit (CH) 2.5Bar, Secondary circuit (DHW) 10.0 Bar Maximum operating temperature 90.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240502720
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Primary circuit (CH) ¾” BSP (M), Secondary circuit (DHW) ½” BSP (M).
Marking:
NAVIEN on front of boiler. NAVIEN, Model Number, Max Pressure and other technical info on adhesive label on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2029
Model:
NCB300-28K NCB300-37K NCB300-41K Model added July 2024 NCB300-30K
Product Images

Approval Holder:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company
Manufacturer:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company

Print This Approval


#240704704

Range of wall mounted gas fired condensing instantaneous water heaters. Maximum working pressure 10.0bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240704704
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP(M) for 10-12L & 14~17L/min (Flow rate) ¾” BSP(M) for 22~26L/min (Flow rate)
Marking:
Company Logo Vanward, model, pressure, tempeture and and other technical info on adhesive label on side panel.
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
10~12L balance type & forces exhaust type gas water heater: JSG=balance type gas water heater, JSQ=forces exhaust type gas water, a= nominal heat input(kW) (fixed from 20, 22 to 24), b=volume (fixed from 10, 11 to 12), STc=Sd= the type of casing (c fixed from 27, 28 to 29, d fixed from 21, 25, 22, 21B, 23, 24, 25(A), 25(B), 26, 27, 28, 31, 32, 34 to 35) Casing 1: ST27, S21, Casing 2: ST28, S25, Casing 3: ST29, S22, Casing 4: S21B, Casing 5: S23, Casing 6: S24, Casing 7: S25(A), Casing 8: S25(B), Casing 9: S26, Casing 10: S27, Casing 11: S28, Casing 12: S31, Casing 13: S32, Casing 14: S34, Casing 15: S35. Where a typical code is: ①JSG28-14ST28、JSG14ST-S25: JSG=balance type gas water heater 28=nominal heat input(kW) 14=volume ST28=the type of casing, ST=structure platform S25=the type of casing 14~17L balance type & forces exhaust type gas water heater: JSG=balance type gas water heater, JSQ=forces exhaust type gas water, a= nominal heat input(kW) (fixed from 20, 22 to 24), b=volume (fixed from 10, 11 to 12), STc=Sd= the type of casing (c fixed from 27, 28 to 29, d fixed from 21, 25, 22, 21B, 23, 24, 25(A), 25(B), 27, 28, 31, 32, 34 to 35). Same casings as above but without casing 9. ②JSG14ST-S25(B) 、JSQ28-14ST28 JSG=balance type gas water heater JSQ=forces exhaust type gas water 14=volume 28=nominal heat input(kW) ST=structure platform S25(B)=the type of casing, ST28=the type of casing 22~26L outdoor type gas water heater: JSW=outdoor type gas water heater, a= nominal heat input(kW) (fixed from 44 to 52), b=volume (fixed from 22 to 26), ST58=Wd= the type of casing (d fixed from 81, 82, 83 to 84), Casing 1: ST58, W81, Casing 2: W82, Casing 3: W83, Casing 4: W84. ③JSW44-22ST58、 JSW22HT-W81: JSW=outdoor type gas water heater 44=nominal heat input(kW) 22=volume ST58=the type of casing, HT=structure platform W81=the type of casing
JSG20-10ST27, JSG10ST-S21, JSQ20-10ST27, JSQ10ST-S21, JSG22-11ST27, JSG11ST-S21, JSQ22-11ST27, JSQ11ST-S21, JSG24-12ST27, JSG12ST-S21, JSQ24-12ST27, JSQ12ST-S21, JSG20-10ST28, JSG10ST-S25, JSQ20-10ST28, JSQ10ST-S25, JSG22-11ST28, JSG11ST-S25, JSQ22-11ST28, JSQ11ST-S25, JSG24-12ST28, JSG12ST-S25, JSQ24-12ST28, JSQ12ST-S25, JSG20-10ST29, JSG10ST-S22, JSQ20-10ST29, JSQ10ST-S22, JSG22-11ST29, JSG11ST-S22, JSQ22-11ST29, JSQ11ST-S22, JSG24-12ST29, JSG12ST-S22, JSQ24-12ST29, JSQ12ST-S22, JSG10ST-S21B, JSQ10ST-S21B, JSG11ST-S21B, JSQ11ST-S21B, JSG12ST-S21B, JSQ12ST-S21B, JSG10ST-S23, JSQ10ST-S23, JSG11ST-S23, JSQ11ST-S23, JSG12ST-S23, JSQ12ST-S23, JSG10ST-S24, JSQ10ST-S24, JSG11ST-S24, JSQ11ST-S24, JSG12ST-S24, JSQ12ST-S24, JSG10ST-S25(A), JSQ10ST-S25(A), JSG11ST-S25(A), JSQ11ST-S25(A), JSG12ST-S25(A), JSQ12ST-S25(A), JSG10ST-S25(B), JSQ10ST-S25(B), JSG11ST-S25(B), JSQ11ST-S25(B), JSG12ST-S25(B), JSQ12ST-S25(B), JSG10ST-S26, JSQ10ST-S26, JSG12ST-S26, JSQ12ST-S26, JSG10ST-S27, JSQ10ST-S27, JSG12ST-S27, JSQ12ST-S27, JSG10ST-S28, JSQ10ST-S28, JSG12ST-S28, JSQ12ST-S28, JSG10ST-S31, JSQ10ST-S31, JSG12ST-S31, JSQ12ST-S31, JSG10ST-S32, JSQ10ST-S32, JSG12ST-S32, JSQ12ST-S32, JSG10ST-S34, JSQ10ST-S34, JSG12ST-S34, JSQ12ST-S34, JSG10ST-S35, JSQ10ST-S35, JSG11ST-S35, JSQ11ST-S35, JSG12ST-S35, JSQ12ST-S35. JSG28-14ST27, JSG14ST-S21, JSQ28-14ST27, JSQ14ST-S21, JSG30-16ST27, JSG16ST-S21, JSQ30-16ST27, JSQ16ST-S21, JSG31-17ST27, JSG17ST-S21, JSQ31-17ST27, JSQ17ST-S21, JSG28-14ST28, JSG14ST-S25, JSQ28-14ST28, JSQ14ST-S25, JSG30-16ST28, JSG16ST-S25, JSQ30-16ST28, JSQ16ST-S25, JSG31-17ST28, JSG17ST-S25, JSQ31-17ST28, JSQ17ST-S25, JSG28-14ST29, JSG14ST-S22, JSQ28-14ST29, JSQ14ST-S22, JSG30-16ST29, JSG16ST-S22, JSQ30-16ST29, JSQ16ST-S22, JSG31-17ST29, JSG17ST-S22, JSQ31-17ST29, JSQ17ST-S22, JSG14ST-S21B, JSQ14ST-S21B, JSG16ST-S21B, JSQ16ST-S21B, JSG17ST-S21B, JSQ17ST-S21B, JSG14ST-S23, JSQ14ST-S23, JSG16ST-S23, JSQ16ST-S23, JSG17ST-S23, JSQ17ST-S23, JSG14ST-S24, JSQ14ST-S24, JSG16ST-S24, JSQ16ST-S24, JSG17ST-S24, JSQ17ST-S24, JSG14ST-S25(A), JSQ14ST-S25(A), JSG16ST-S25(A), JSQ16ST-S25(A), JSG17ST-S25(A), JSQ17ST-S25(A), JSG14ST-S25(B), JSQ14ST-S25(B), JSG16ST-S25(B), JSQ16ST-S25(B), JSG17ST-S25(B), JSQ17ST-S25(B), JSG14ST-S27, JSQ14ST-S27, JSG16ST-S27, JSQ16ST-S27, JSG14ST-S28, JSQ14ST-S28, JSG16ST-S28, JSQ16ST-S28, JSG14ST-S31, JSQ14ST-S31, JSG16ST-S31, JSQ16ST-S31, JSG14ST-S32, JSQ14ST-S32, JSG16ST-S32, JSQ16ST-S32, JSG14ST-S34, JSQ14ST-S34, JSG16ST-S34, JSQ16ST-S34, JSG14ST-S35, JSQ14ST-S35,JSG16ST-S35, JSQ16ST-S35. JSW44-22ST58, JSW22HT-W81, JSW52-26ST58, JSW26HT-W81, JSW22HT-W82, JSW26HT-W82, JSW22HT-W83, JSW26HT-W83, JSW22HT-W84, JSW26HT-W84.
Product Images

Approval Holder:
Guangdong Vanward New Electric Co. Ltd.
Company Name
Guangdong Vanward New Electric Co. Ltd.
Address
13 Jianye Mid- Road Shunde High Tech Industry Development Zone
Country
Ronggui Shunde

View All Listings by this Company
Manufacturer:
Guangdong Vanward New Electric Co. Ltd.
Company Name
Guangdong Vanward New Electric Co. Ltd.
Address
13 Jianye Mid- Road Shunde High Tech Industry Development Zone
Country
Ronggui Shunde

View All Listings by this Company

Print This Approval


#240904726

‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240904726
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
22mm compression (Primary Circuit) 15mm compression (Secondary Circuit)
Marking:
E.C.A. on front cover. E.C.A, model and technical information including KW rating on adhesive label on body.
Installation Requirements:
R001 R360
Expiry date:
30/09/2029
Model:
8116350010 CALORA PREMIX 24 HM ERP UK 8116484110 CALORA PREMIX 14 HM ERP UK 8116487110 CALORA PREMIX 20 HM ERP UK 8116356010 CALORA PREMIX 28 HM ERP UK 8116389010 CITIUS PREMIX 14 HM ERP UK 8116392010 CITIUS PREMIX 20 HM ERP UK 8116353010 CITIUS PREMIX 24 HM ERP UK 8116380010 CITIUS PREMIX 28 HM ERP UK 8116576110 Proteus Premix 42 HM DG ERP UK 8116550010 Proteus Premix 45 HM DG ERP UK
Product Images

Approval Holder:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company

Print This Approval


#241104709

Range of indirect heat interface units (HIU) providing heating and instantaneous hot water. The central heating and hot water is generated via plate heat exchangers. Maximum operating pressure 10 bar (primary and DHW secondary). Maximum operating pressure 2.5 bar CH secondary Maximum operating temperature 90°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
241104709
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
22mm compression
Marking:
Bosch on front panel and technical info on adhesive label.
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2029
Model:
7-735-600-739 - Flow 8500 40, 7-735-600-740 - Flow 8500 40 H, 7-735-600-741 - Flow 8500 50, 7-735-600-742 - Flow 8500 50 H, 7-735-600-743 - Flow 8500 60, 7-735-600-744 - Flow 8500 60 H.
Product Images

Approval Holder:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Danesmoor Works Pilsley Clay Cross Chesterfield Derbyshire
Postcode
S45 9BY

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 3 of 3

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.