Directory Search Results

Print List

#241202010

Range of brass (CW617 or CW511L) press fit fittings (M-Type) for use with copper pipe manufactured to EN 1057. Maximum working pressure: 16 Bar. Maximum operating temperature: 99°C.

Section:
1180 Fittings for use with Tube and Pipe
Section Subtitle:
Couplings. Unless specified in the individual approval, the products within this section are not suitable for below ground use
WRAS Approval Number:
241202010
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See Models below
Marking:
Ningbo Jintian (JT) Logo, Size and WRAS on body.
Installation Requirements:
R001
Expiry date:
31/12/2029
Model:
BP5240F Coupler: 15mm – 54mm x 1/2" BSP – 2” BSP (F). BP5243M Coupler: 12mm – 54mm x 3/8" BSP – 2” BSP (M). BP5090F Elbow: 12mm – 54mm x 3/8" BSP – 2” BSP (F). BP5092F Elbow: 12mm – 54mm x 3/8" BSP – 2” BSP (M). BP5094F Wallplate elbow: 15mm – 28mm x 1/2" BSP – 1” BSP (F). BP5130F Branch Tee: 15mm – 54mm x 15mm – 54mm x 3/8" BSP – 2” BSP (F). BP5240G Straight swivel: 15mm – 28mm x 1/2" BSP – 1 1/4” BSP (F). BP9201M Male union coupler: 12mm – 54mm x 3/8" BSP – 2” BSP (M). BP9202F Male union with Female end: 12mm – 54mm x 3/8" BSP – 2” BSP (F). BP9203PP Coupler: 12mm – 54mm. BPA9270F Female nipple: 12mm – 35mm. BPA9272M Male Nipple: 12mm – 54mm.
Product Images

Approval Holder:
Ningbo Jintian Copper Tube Co Ltd
Company Name
Ningbo Jintian Copper Tube Co Ltd
Address
No.1 ChengXi West Road, CiCheng, NingBo
Country
China
Phone
0086 574 8757 4425
General Email
audrey@jtcorp.com.cn

View All Listings by this Company

Print This Approval


#2107159

Range of WC dual flush drop valve comprising of a plastic body, silicone seating washer and an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2107159
Note:
Open outlet use only.
Size:
See models.
Marking:
Plumbright on the body. WRAS & Model code on body
Installation Requirements:
R001 R571
Expiry date:
31/07/2026
Model:
137004 PLUMBRIGHT: 1½” BSP (M),

Approval Holder:
The Highbourne Group, City Plumbing Supplies
Company Name
The Highbourne Group, City Plumbing Supplies
Address
Branch Support Centre Highbourne House Highbourne House Crick Northampton
Postcode
NN6 7SL
Country
United Kingdom
Phone
07342 078865
General Email
Lindsey.cocks-stevens@cityplumbing.co.uk

View All Listings by this Company

Print This Approval


#241202701

Range of WC single flush flapper valves with an ABS body. The valves are operated via a lever handle or a push button assembly and incorporate an internal overflow. Cold water use only

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
241202701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1½” BSP (M)
Marking:
Fluidmaster logo and patent number on flapper.
Installation Requirements:
R001 R571
Expiry date:
31/12/2029
Model:
507UKK071, 507UKK073, PRO71UK & PRO73UK
Product Images

Manufacturer:
Fluidmaster, Inc.
Company Name
Fluidmaster, Inc.
Address
30800 Rancho Viejo Road San Juan Capistrano
Postcode
CA 92675
Country
United States
Phone
1-949-796-2653

View All Listings by this Company

Print This Approval


#241202710

Range of near boiling hot water dispensers with stainless steel tanks and flow is controlled via float switch. Maximum working pressure 3 Bar. Maximum operating temperature 98°C.

Section:
1380 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, closed outlet. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within with system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
241202710
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
3/8” BSP M inlet/outlet
Marking:
New Lanbiao logo on label on front of body. Model and product info on label on rear of body.
Installation Requirements:
R001
Expiry date:
31/12/2029
Model:
51023, 51006, 51022-H, 51005-H, 51022-B, 51005-B
Product Images

Approval Holder:
Taizhou New Lanbiao Intelligent Technology Co.,Ltd
Company Name
Taizhou New Lanbiao Intelligent Technology Co.,Ltd
Address
JIAOXI INDUSTRIAL ZONE, QINGGANG, YUHUAN, TAIZHOU
Country
China

View All Listings by this Company

Print This Approval


#2310403

Range of water meters with epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1505 Water Meters
Size:
2½” BSP (M) connection. DN40, DN50, DN65, DN80, DN100, DN125, DN150, DN200, DN250, DN300 flanged connections.
Marking:
Resideo & Technical information on face. Size and flow arrow on body.
Installation Requirements:
R001
Expiry date:
31/10/2028
Model:
EW1710AC5000 EW1710AC5600 EW1710AC6500 EW1710AC7300 EW1710AC8100 EW1710AC8500 EW1710AC8900 EW1710AC9100 EW1710AC9200

Approval Holder:
Pittway Sarl
Company Name
Pittway Sarl
Address
A3 - ZA La Pièce 6 1180 Rolle
Country
Switzerland

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1935 of 2240

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.