Cistern - Flushing

Section Code 2035 : Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.

Back To Directory Sections

#2012120

WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2012120
Size:
½” BSP (M)
Marking:
BAGNODESIGN and model number on cistern body. 6 litre line inside cistern
Installation Requirements:
R001 R556
Expiry date:
31/12/2025
Model:
BDS-K210-A01-ESG6 UNIVERAL FRAMED 820 CONCEALED CISTERN FOR WALL HUNG WC BDS-K210-D03-ESG3 CONCEALED CISTERN FOR BACK TO WALL WC

Approval Holder:
BAGNODESIGN
Company Name
BAGNODESIGN
Address
UNIT 1 OAKWELL PARK TRADING ESTATE BIRSTALL
Postcode
WF17 9LU

View All Listings by this Company

Print This Approval


#250102706

Concealed WC dual flushing cisterns with a BS 1212- 4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a manually operated dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. The inlet supply incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
250102706
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M)
Marking:
Honjim logo and WRAS logo on cistern cover. 6 litre line inside cistern.
Installation Requirements:
R001 R556
Expiry date:
31/01/2030
Model:
G-1030
Product Images

Approval Holder:
Zhejiang Honjim Intelligent Technology Co., Ltd
Company Name
Zhejiang Honjim Intelligent Technology Co., Ltd
Address
Port-neighboring Industrial estate, Jiantiao Town, Sanmen County, Taizhou City, Zhejiang Province,China

View All Listings by this Company

Print This Approval


#250401701

WC Cistern incorporating a side or bottom entry float operated inlet valve and a dual flush Drop Valve (Acclaim V) or Syphon (Acclaim S) of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by lever or manual push button. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
250401701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP Male inlet connection.
Marking:
‘Cascade +’ or ‘Dudley Turbo’ on syphon. ‘Dudley’ and ‘TD’ on drop valve ‘HYDROFLO’.‘DUDLEY BS 1212/4’ inlet valve, Thomas Dudley Ltd on cistern. 6 litre line inside cistern
Installation Requirements:
R001 R280 R556
Expiry date:
30/04/2030
Model:
Acclaim V & Acclaim S.

Approval Holder:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company
Manufacturer:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 20 of 20

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.