Range of wall mounted electric showers (various finishes). The GSD/BETTER models incorporate a solenoid valve controlling the flow, which includes a combined plastic and stainless steel strainer and a plastic flow regulator on its inlet. The GSM/DSK/ENTRY models incorporate a manually operated push button valve controlling the flow and plastic strainer on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 53°C. Cold supply only.
Range of wall mounted electric showers (various finishes). Incorporate a manually operated push button valve controlling the flow and plastic strainer on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 53°C. Cold supply only.
Range of wall mounted electric showers (various finishes). The GSD models incorporate a solenoid valve controlling the flow, which includes a combined plastic and stainless steel strainer and a plastic flow regulator on its inlet. The GSM/ models incorporate a manually operated push button valve controlling the flow and plastic strainer on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 53°C. Cold supply only.
Range of single hole, single outlet, fixed, electronically controlled tap assemblies with brass bodies (various finishes), incorporating an electronic cartridge controlling the flow which is activated via an infrared sensor (either battery or mains powered). Models 31 171 xxx & 31 173 xxx incorporates a manually operated temperature control. The inlet adapters incorporate stainless steel filters and single check valve cartridges verified by test (suitable for backflow protection against Fluid Category 2 ). The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
WC flushing cistern incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 5.5 litres and a reduced flush of up to 2.7 litres and incorporates a servicing valve and flexible hose on the inlet supply. The cistern is operated by a manually operated push button. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of in-line, non-verifiable single check valve assemblies with DZR brass bodies and spring loaded, resilient trim check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC
Range of in-line non-verifiable single check valve assemblies consisting of a spring loaded resilient trim single check valve cartridge housed within a DZR brass or nickel plated DZR brass body. Compression models are for use with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Page 181 of 780
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.