Directory Search Results

Print List

#2011100

Range of in-line adjustable pressure reducing valves, with DZR brass bodies and EPDM seat washers & ‘o’ rings and stainless-steel filters. Various models supplied with pressure gauge (please see model list). Maximum inlet supply pressure 16.0 bar. Outlet pressure range: 0.8-6.0 bar. Maximum operating temperature 80°C.

Section:
2200 Valves
Section Subtitle:
Pressure reducing.
WRAS Approval Number:
2011100
Size:
See Models
Marking:
CR, size & flow arrow on body. RBM on cap/operating member.
Installation Requirements:
R001 R120
Expiry date:
30/11/2025
Model:
ART 670 F DN 15– ½” BSP (F) (With Gauge), ART 670 F DN 20 – ¾” BSP (F) (With Gauge). ART 670 M DN 25 – 1” BSP (M) (With Gauge). ART 670 M DN 32 – 1”1/4 BSP (M) (With Gauge). ART 670 M DN 40 – 1”1/4 BSP (M) (With Gauge). ART 670 M DN 50 – 2” BSP (M) (With Gauge).

Approval Holder:
Albion Valves (UK) Limited
Company Name
Albion Valves (UK) Limited
Address
9a Fallbank Industrial Estate Dodworth Barnsley
Postcode
S75 3LS
Country
United Kingdom
Phone
01226 729900
General Email
samjed@albionvalvesuk.com

View All Listings by this Company
Manufacturer:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company

Print This Approval


#2010095

Range of in-line, manually adjustable pressure reducing valves with blue epoxy coated ductile iron bodies and EPDM gaskets and ‘O’-rings (all models) and an EPDM diaphragm (VRCD-M models only). VRCD models: Outlet pressure range: 1.5 - 6.0 bar or 5.0 to 12.0 bar. VRCD-M models: Outlet pressure range: 1.5 - 6.0 bar. Maximum supply pressure 16.0 bar. Cold water use only.

Section:
2200 Valves
Section Subtitle:
Pressure reducing.
WRAS Approval Number:
2010095
Size:
DN50 to DN150 flanged inlet and outlet.
Marking:
CSA and technical information on data plate on body. CSA DN and flow arrow on body.
Installation Requirements:
R001 R120
Expiry date:
31/10/2025
Model:
VRCD Direct acting pressure reducing/stabilizing valve. VRCD-M Direct acting pressure reducing/stabilizing valve with diaphragm.

Approval Holder:
CSA S.r.l
Company Name
CSA S.r.l
Address
Strada San Giuseppe 15 Localita Ponteghiara - 43039 Salsomaggiore Terme (PR)
Country
Italy
Phone
+390524523978
General Email
peter@ttflow.com

View All Listings by this Company

Print This Approval


#2103026

Range of normally open or closed solenoid valves incorporating a brass body, EPDM diaphragm and ‘O’-rings. Maximum working pressures: SCE210C034BW, SCE210C035BW: AC and DC 9.0 bar. SCE210C094BW, SCE210D095BW: AC 9.0 bar, DC 3.0 bar. Maximum operating temperature 85°C.

Section:
2230 Valves
Section Subtitle:
Solenoid, metal.
WRAS Approval Number:
2103026
Size:
SCE210C034BW: ½” BSP (F). SCE210C094BW: ½” BSP (F). SCE210C035BW: ¾” BSP (F). SCE210D095BW: ¾” BSP (F).
Marking:
ASCO (trademark of Emerson Automation Fluid control & Pneumatics), CE, size, model number and year of manufacture (YYYY) on adhesive label on coil. ASCO on valve body.
Installation Requirements:
R001
Expiry date:
31/03/2026
Model:
SCE210C034BW (normally open). SCE210C035BW (normally open). SCE210C094BW (normally closed). SCE210D095BW (normally closed).
Product Images

Approval Holder:
Emerson Automation Fluid Control & Pneumatics Italy Srl.
Company Name
Emerson Automation Fluid Control & Pneumatics Italy Srl.
Address
Strada per Cernusco 19 20060 Bussero (MI)
Country
Italy

View All Listings by this Company
Manufacturer:
Emerson Automation Fluid Control & Pneumatics UK Ltd & Emerson Automation Fluid Control & Pneumatics Poland Sp. z.o. o
Company Name
Emerson Automation Fluid Control & Pneumatics UK Ltd & Emerson Automation Fluid Control & Pneumatics Poland Sp. z.o. o
Postcode
WN8 9PG

View All Listings by this Company

Print This Approval


#2101028

A range of normally closed servo-assisted diaphragm solenoid valves with brass bodies and EDPM diaphragms. Models 23C, 23D, 23E & 23F have a maximum working pressure of 16.0 bar. Models 23G, 23H & 23I have a maximum working pressure of 10.0 bar. Cold water use only

Section:
2235 Valves
Section Subtitle:
Solenoid, metal - for non-wholesome water use only.
WRAS Approval Number:
2101028
Size:
3/8” – 2” BSP (F)
Marking:
Banico on coil. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
31/01/2026
Model:
23C, 23D, 23E & 23F 23G, 23H & 23I.
Product Images

Approval Holder:
Banico
Company Name
Banico
Address
Dallimore Road Manchester M239NX

View All Listings by this Company
Manufacturer:
Banico
Company Name
Banico
Address
Dallimore Road Manchester M239NX

View All Listings by this Company

Print This Approval


#2101053

Range of bistable (all models) or monostable/normally closed (19.00x.287 only) solenoid valves with either a plastic body (19.00X.287) or plastic internal body with stainless steel threaded casing (50.005.102 and 50.005.(050) models) with EPDM diaphragms and ‘O’-rings. Maximum working pressures: 50.005.(050) model: 8.0 bar. All other models: 10.0 bar. Maximum operating temperature 70°C

Section:
2240 Valves
Section Subtitle:
Solenoid, plastic.
WRAS Approval Number:
2101053
Size:
Please refer to model.
Marking:
A. u. K. Müller, model number, manufacturing date (WW/YY) & technical information on adhesive label on body.
Installation Requirements:
R001 R008
Expiry date:
31/01/2026
Model:
50.005.(050): M20. 50.005.102: M20. 19.00X.287: OD 7.5mm.
Product Images

Approval Holder:
A.u.K. Müller GmbH & Co. KG
Company Name
A.u.K. Müller GmbH & Co. KG
Address
Dresdener Str. 162, D-40595 Düsseldorf
Country
Germany
Phone
+49 211 7391 0
General Email
info@akmueller.de

View All Listings by this Company
Manufacturer:
A.u.K. Müller GmbH & Co. KG
Company Name
A.u.K. Müller GmbH & Co. KG
Address
Dresdener Str. 162, D-40595 Düsseldorf
Country
Germany
Phone
+49 211 7391 0
General Email
info@akmueller.de

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 161 of 2032

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.