Directory Search Results

Print List

#260302021

Range of heat interface units with copper brazed, stainless-steel heat exchangers, providing heating and instantaneous hot water. The product incorporates an expansion vessel, a safety relief valve on the heating circuit set @ 3.0 bar and another on the cold-water inlet set @ 10.0 bar. Maximum working pressures: Primary: 16.0 bar Heating circuit: 2.5 bar Secondary: 9.5 bar Maximum operating temperatures: Primary: 90.0°C Heating circuit: 85.0°C Secondary: 60.0°C

Section:
1350 Heat Exchangers
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP captive nut
Marking:
Taconova production, model code, primary, secondary and other technical information on label on expansion vessel
Installation Requirements:
R001
Expiry date:
31/03/2031
Model:
274.2401.696 - TacoTherm Dual ZEPTO SMART 10/26 without HM 274.2411.000P - TacoTherm Dual ZEPTO SMART 10/26 (PPR) 274.2411.696 - TacoTherm Dual ZEPTO SMART 10/26 274.2412.696 - TacoTherm Dual ZEPTO SMART 10/26 (WF) 274.2412.696MB - TacoTherm Dual ZEPTO SMART 10/26 (HM_ModBUS) 274.2412.696S - TacoTherm Dual ZEPTO SMART 10/26 (WF,DCWS) 274.2612.696C - TacoTherm Dual ZEPTO SMART 10/40 (WF,HI - FL) 274.2712.696CS - TacoTherm Dual ZEPTO SMART 10/50 (WF, HI - FL, DCWS) 274.2712.696S - TacoTherm Dual ZEPTO SMART 10/50 (WF,DCWS) 274.2912.696C - TacoTherm Dual ZEPTO SMART 10/70 (WF,HI - FL) 274.4412.696 - TacoTherm Dual ZEPTO SMART 16/26 (WF) 274.4711.696 - TacoTherm Dual ZEPTO SMART 16/50 (WF) 274.4912.696C - TacoTherm Dual ZEPTO SMART 16/70 (WF,HI - FL) 274.6401.696 - TacoTherm Dual ZEPTO SMART 26/26 without HM 274.6411.696 - TacoTherm Dual ZEPTO SMART 26/26 274.6412.696 - TacoTherm Dual ZEPTO SMART 26/26 (WF) 274.6612.696 - TacoTherm Dual ZEPTO SMART 26/40 (WF) 274.6712.696 - TacoTherm Dual ZEPTO SMART 26/50 (WF) 274.6712.696CS - TacoTherm Dual ZEPTO SMART (WF, HI - FL, DCWS) 274.6712.696S - TacoTherm Dual ZEPTO SMART 26/50 (WF, DCWS) 274.6912.696C - TacoTherm Dual ZEPTO SMART 26/70 (WF,HI - FL) 274.8611.696 - TacoTherm Dual ZEPTO SMART 40/40 (WF) 274.8912.696C - TacoTherm Dual ZEPTO SMART 40/70 (WF,HI - FL) First digit xx/xx is the number of plates of the heat exchanger for the heating distribution; second digit xx/xx is the number of plates of the heat exchanger for the drinking water heating. Models with a “9” (xxx.xx9x.xxx) instead of a “1” are exactly the same as the models with a 1 but will be supplied with the following extras: - Heatmeter - Flushing Bypass - Safety Valve Following the explanation of description in the product name: - Without HM = Without Heatmeter - PPR = Prepayment valve - WF = With a white Front plate - ModBUS = ModBUS Connectivity - DCWS = Domestic cold water supply - HI-FL = Other PICV (Pressure Independent Control Valve ) on primary side

Approval Holder:
Taconova UK Limited
Company Name
Taconova UK Limited
Address
Technology Centre | Advanced Manufacturing Park | Brunel Way Rotherham
Postcode
S60 5WG
Country
UK

View All Listings by this Company
Manufacturer:
Taconova Production s.r.o.
Company Name
Taconova Production s.r.o.
Address
Nova UL. C 627, CZ-38232 Velesin, Czech Republic

View All Listings by this Company

Print This Approval


#260302701

Electric vented mains water heater with metal housing and silicon rubber gaskets. The inlet incorporates a combined EPDM washer and stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 98°C. Open outlet use only.

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
260302701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Inlet: ¼” LLDPE pipe. Outlet: ⅜” BSP (M).
Marking:
Abode on front of body. Model name and other technical information on adhesive label on rear of body.
Installation Requirements:
R001 R008
Expiry date:
31/03/2031
Model:
PROBOIL.3X

Approval Holder:
Norcros Group (Holdings) Limited T/A Abode
Company Name
Norcros Group (Holdings) Limited T/A Abode
Address
Unit L Zenith Park Whailey Road Barnsley
Postcode
S75 1HT
Country
United Kingdom
Phone
01226 283434
General Email
info@abode.eu

View All Listings by this Company

Print This Approval


#260302018

Range of pressure sensors with stainless steel bodies, EPDM ‘O’-ring and ceramic measuring cell. Maximum working pressure 25.0 bar. Cold water use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
B82.a-b-LF-e-f-g-h-i-j-k-l-m-n-o-p & B28/B38.ab-c-d-LF-g-h-i-j-k: ½” NPT (M) ¼” NPT inside (F). B82.a-b-CS-e-f-g-h-i-j-k-l-m-n-o-p & B28/B38.ab-c-d-CS-g-h-i-j-k: ½” BSP (M). B82.a-b-C5-e-f-g-h-i-j-k-l-m-n-o-p & & B28/B38.ab-c-d-C5-g-h-i-j-k: 1” BSP (M). B82.a-b-N7/B2/BC/B5/D8/N8/4G/D4/TP/CQ/5O/U8/U6/CH/PX/VE-e-f-g-h-i-j-k-l-m-n-o-p: DN25, DN50 and DN80 flanged.
Marking:
B82 models: VEGA on body. VEGA, model, serial number, date of manufacture (YYYY) and other technical information on adhesive label or data plate on body. B28/38 models: VEGA, serial number, date of manufacture (YYYY) and other technical information on body.
Installation Requirements:
R001
Expiry date:
31/03/2031
Model:
VEGABAR 82 range: B82.a-b-cd-e-f-g-h-i-j-k-l-m-n-o-p a = Scope: A - Europe I - worldwide V - Combination (Europe, world-wide) b = Approval: • X - for Ex-free area • W - Overfill protection (WHG, VLAREM) • M - Ship approval (DNV, BV, ABS, CCS, LR, RINA, ClassNK) • M - Ship approval (DNV, BV, ABS, CCS, LR, RINA, ClassNK) incl. MED • C - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 • U - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 + Overfill protection (WHG, VLAR EM) • O - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 + Ship approval • O - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 + ship approval incl. MED • H - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 + II 1D, 1/2D, 1/3D, Ext IIIC T* • T - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 + 1/2/-D Ex t IIIC IP67/I66 • E - ATEX/UKEX II 1/2G, 2G Ex d IIC T6 • Z - ATEX/UKEX II 1/2G, 2G Ex d IIC T6 + Overfill protection (WHG, VLAREM) • Q - ATEX/UKEX II 1/2G, 2G Ex d IIC T6 + Ship approval • Q - ATEX/UKEX II 1/2G, 2G Ex d IIC T6 + ship approval incl. MED • J - ATEX/UKEX II 1/2G, 2G Ex d IIC T6 + II 1D, 1/2D, 1/3D, 2D Ext IIIC T* • R - ATEX/UKEX II 1D, 1/2D, 1/3D, 2D Ext IIIC T* • S - ATEX/UKEX II 1/2/-D Ex t IIIC IP67/IP66 T* Da/Db/- • C - IEC Ex ia IIC T6 • U - IEC Ex ia IIC T6 + Overfill protection (WHG, VLAREM) • IEC Ex ia IIC T6 + Ship approval • H - IEC Ex ia IIC T6 + IEC Ex t IIIC T* • T - IEC Ex ia IIC T6 + IECEx Ex ia/ia/-, ia/tb ia IIC TX°C Da/Db/-, Da/Db • D - IEC Ex d ia IIC T6 • P - IEC Ex d ia IIC T6 + Ship approval • I - IEC Ex d ia IIC T6 + IEC Ex t IIIC T* • E - IEC Ex d IIC T6 • Q - IEC Ex d IIC T6 + Ship approval • J - IEC Ex d IIC T6 + IEC Ex t IIIC T* • R - IEC Ex t IIIC T* • S - IEC Ex ia/ia/-, ia/tb ia IIIC TX°C Da/Db/-, Da/Db • C - ATEX / IEC II 1G, 1/2G, 2G Ex ia IIC T6 / Ex ia IIC T6 • O - ATEX / IEC II 1G, 1/2G, 2G Ex ia IIC T6 / Ex ia IIC T6 + Ship approval • E - ATEX / IEC II 1/2G, 2G Ex d IIC / Ex d IIC T6 cd = Process fitting / Material (NOTE: PN rating relates to the flange and not the products maximum working pressure): • LF - Thread ½NPT, inside ¼NPT, ASME B1.20.1 / 316L • CS - Thread G½, ISO228-1, inside ø 11.4mm / Duplex (1.4462) • C5 - Thread G1, ISO228-1 / 316L • N7 - Flange DN25 PN40 Form C, DIN2501 / 316/316L • B2 - Flange DN50 PN40 Form C, DIN2501 / 316/316L • BC - Flange DN50 PN40 Form B, DIN2501 / 316/316L • B5 - Flange DN80 PN40 Form C, DIN2501 / 316/316L • D8 - Flange DN25 PN40 Form C, EN1092-1 / 316/316L • N8 - Flange DN25 PN40 Form B1, EN1092-1 / 316/316L • 4G - Flange DN25 PN40 Form B1, EN1092-1 / Duplex (1.4462) • D4 - Flange DN50 PN40 Form C, EN1092-1 / 316/316L • TP - Flange DN50 PN40 Form B1, EN1092-1 / 1.4435 (BN2) • CQ - Flange DN50 PN40 Form B1, EN1092-1 / 316/316L • 5O - Flange DN50 PN40 Form B1, EN1092-1 / Duplex (1.4462) • U8 - Flange DN50 PN40 Form B1, EN1092-1 / 1.4435 (BN2), (Ra<0.38μm) • U6 - Flange DN80 PN40 Form B1, EN1092-1 / 1.4435 (BN2), (Ra<0.38μm) • CH - Flange DN80 PN40 Form B1, EN1092-1 / 316/316L • PX - Flange DN80 PN40 Form B1, EN1092-1 / Duplex (1.4462) • VE - Flange DN80 PN40 Form C, EN1092-1 / 316/316L e = Sealing concept: • D – Double Seal f = Measuring cell seal / Process temperature • D - EPDM • E - EPDM g = Pressure • Relative pressure (measurement against atmosphere) • Absolute pressure (measurement against vacuum) • Relative pressure climate-compensated (measurement against atmosphere) h = Measuring range • Absolute: 0...+0.025 bar to 0...+25.0 bar • Relative: -1...0.0 bar to -1...+25.0 bar i = Accuracy class • Different accuracy classes from 0.05 % to 0.20 % j = Electronics • Z - Two-wire 4 ... 20 mA • H - Two-wire 4 ... 20 mA/HART • U - Four-wire Modbus (converter in second chamber) • A - Two-wire 4 ... 20 mA/HART with SIL qualification • P - Two-wire Profibus PA • F - Two-wire Foundation Fieldbus • S - Secondary electronics for electronic differential pressure • T - Secondary electronics for electronic differential pressure with SIL qualification k = Supplementary electronics • X - without • Z - Additional current output 4 ... 20 mA l = Housing • K - Plastic single chamber • R - Plastic double chamber • A - Aluminium single chamber • D - Aluminium double chamber • V - Stainless steel single chamber (precision casting) • W - Stainless steel double chamber (precision casting) • 8 - Stainless steel single chamber (electropolished) m = Housing version / Protection I - compact / IP66/IP67; TYPE 4X • D - compact / IP66/IP68 (0.2bar); TYPE 6P • P - compact / IP66/IP67; TYPE 4X with M12x1 for VEGADIS 81 • N - compact / IP66/IP68 (1bar); TYPE 6P • M - compact / IP67/IP69 TYPE 4X • A - Axial cable outlet IP68 (PUR) with external housing / IP66/IP67; TYPE 4X • C - Lateral cable outlet IP68 (PUR) with external housing / IP66/IP67; TYPE 4X • K - Axial cable outlet IP68 (PE) with external housing / IP66/IP67; TYPE 4X • L - Lateral cable outlet IP68 (PE) with external housing / IP66/IP67; TYPE 4X • T - Cable outlet / IP66/IP67 TYPE 4X n = Cable entry / Connection • M - M20x1.5 / Cable gland PA black (ø5-9mm), standard • S - M20x1.5 / Cable gland PA black (ø6-12mm) • T - M20x1.5 / Cable gland PA black (ø10-14mm) • K - M20x1.5 / Cable gland PA blue (ø5-9mm) • U - M20x1.5 / Cable gland PA blue (ø6-12mm) • V - M20x1.5 / Cable gland PA blue (ø10-14mm) • L - M20x1.5 / Cable gland stainless steel (ø7-12mm) • O - M20x1.5 / Cable gland brass nickel-plated (ø6-12mm) • 2 - M20x1.5 / Cable gland brass nickel-plated (ø5-9mm) • 9 - M20x1.5 / Cable gland brass nickel-plated SFLU10-M (ø6-12mm) • D - M20x1.5 / Blind plug • 1 - M20x1.5 / without • 6 - M20x1.5 / Cable gland brass nickel-plated; for shielded cable (ø9-13mm) • N - ½NPT / Blind plug • Q - ½NPT / without • J - ½NPT / Cable gland PA black (ø5-9mm) • 8 - ½NPT / Cable gland brass nickel-plated; for reinforced cable (ø9-13mm) • P - ½NPT / Cable gland brass nickel-plated (ø6-12mm) • C - M20x1.5 / Plug connector M12x1, assignment A • B - M20x1.5 / Plug connector M12x1, assignment B • R - M20x1.5 / Plug connector M12x1, assignment C • I - M20x1.5 / Plug connector acc. to ISO4400 • F - M20x1.5 / Plug connector Harting HAN 7D (straight) • G - M20x1.5 / Plug connector Harting HAN 7D (bent) • H - M20x1.5 / Plug connector Harting HAN 8D (straight) • W - M20x1.5 / Plug connector Harting HAN 8D (bent) • Z - ½NPT / Plug 7/8NPT o = Display/adjustment module PLICSCOM • X - without • A - mounted • F - without; lid with inspection window • H - mounted, with heating • B - laterally mounted • K - mounted; with Bluetooth, magnetic pen operation • L - laterally mounted; with Bluetooth, magnetic pen operation p = Certificates • M – Yes o Foodstuff/Pharmaceutical certificate: ▪ WRAS VEGABAR 28 range: B28.ab-c-d-ef-g-h-i-j-k ab = Explosion protection: • XX - for Ex-free area (CE, UKCA, RCM, c-UL-us) • VA - ATEX/UKEX; Gas, increased safety, Zone 2: II 3G Ex ec IIC T4 Gc • VC - ATEX/UKEX/IEC/c-UL-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) • VR - ATEX/IEC/c-UL-us; Gas, intrinsic safety (Class I Division 1,2), Zone 0, 0/1, 1, 2 + dust, protection by enclosure, Zone 20, 20/21, 21 (Class II Division 1) (in preparation: UKEX) • XX - for Ex-free area (EAC) c = Ship approval: • S - with (DNV, LR, ABS, RINA, CCS, NK, BV) • X - without d = Foodstuff/Pharmaceutical certificate • W - with (WRAS) ef = Process fitting / Material: • LF - Thread ½NPT, inside ¼NPT, ASME B1.20.1 / 316L • CS - Thread G½, ISO228-1, inside ø 11.4 mm / Duplex (1.4462) • C5 - Thread G1, ISO228-1; front-flush / 316L g = Measuring cell seal / Process temperature: • D - EPDM h = Measuring range: • Different measuring ranges – both absolute and relative. • Starting from 0…+0.1 bar up to 0…+25.0 bar i = Electrical connection / Protection: • M - M12x1 plastic/ IP66/IP67/IP69 • E - M12x1 stainless steel / IP66/IP67/IP69 • S - 4-pole plug connection ISO4400 M16 / IP65 • K - 4-pole plug connection with hinged cover ISO4400 / IP 65 • T - with direct cable outlet / IP66/IP68 (0.5bar) • V - with direct cable outlet of stainless steel / IP66/68 (0.5bar) j = Electronics: • Z - Two-wire: 4...20 mA • C - Three-wire: transistor, 4...20 mA (active) • A - Three-wire: IO-Link, transistor, 4...20 mA (active) k = Sensor setting via smartphone and VEGA Tools app: • B - with • X - without VEGABAR 38 range: B38.ab-c-d-ef-g-h-i-j-k ab = Explosion protection: • XX - for Ex-free area (CE, UKCA, RCM, c-UL-us) • VC - ATEX/UKEX/IEC/c-UL-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) • XX - for Ex-free area (EAC) c = Ship approval: • S - with (DNV, LR, ABS, RINA, CCS, NK, BV) • X - without d = Foodstuff/Pharmaceutical certificate • W - with (WRAS) ef = Process fitting / Material: • LF - Thread ½NPT, inside ¼NPT, ASME B1.20.1 / 316L • CS - Thread G½, ISO228-1, inside ø 11.4 mm / Duplex (1.4462) • C5 - Thread G1, ISO228-1; front-flush / 316L g = Measuring cell seal / Process temperature: • D - EPDM h = Measuring range: • Different measuring ranges – both absolute and relative. • Starting from 0…+0.1 bar up to 0…+25.0 bar i = Electrical connection / Protection: • M - M12x1 / IP66/IP67 • S - 4-pole plug connection ISO4400 M16 / IP65 • K - 4-pole plug connection with hinged cover ISO4400 / IP 65 j = Electronics: • Z - Two-wire: 4...20 mA • C - Three-wire: transistor, 4...20 mA (active) • A - Three-wire: IO-Link, transistor, 4...20 mA (active) k = Sensor setting via smartphone and VEGA Tools app: • B - with • X - without

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


#260302023

Range of tapping tees with gunmetal bodies and plastic fitting, for use with SDR11 & SDR17 Polyethylene barrier pipes (manufactured to BS8588). For pipe diameters between 63mm & 90mm, the adaptor plate must be used. When used with SDR11 pipes the maximum working pressure is 16.0 bar. When used with SDR17 pipes the maximum working pressure is 10.0 bar. Cold water use, for below ground only.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
260302023
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
Because there are no accepted tests, WRAS approval of barrier pipe does not include an assessment of its ability to prevent migration of contaminants through the wall of the pipe from the surrounding soil.
Size:
Please refer to model.
Marking:
Radius systems on stem cap. Radius systems and size on metal strap.
Installation Requirements:
R001
Expiry date:
31/03/2031
Model:
XR5125 Easi Fit Puriton Tapping Tee: DN63 - DN180 x 25mm Compression. XR5130 Easi Fit Puriton Tapping Tee: DN63 - DN180 x 32mm Compression.

Approval Holder:
Radius Systems Limited
Company Name
Radius Systems Limited
Address
Radius House, Berristow Lane, South Normanton, Alfreton, Derbyshire
Postcode
DE55 2JJ
Country
United Kingdom
Phone
01773582303

View All Listings by this Company

Print This Approval


#260302024

Range of pressure transmitters with stainless steel bodies. The DST P140 G1/4 A (with O-ring) model also incorporates an EPDM ‘O’-ring. Maximum working pressure 50.0 bar. Maximum operating temperatures: DST P140 G1/4 A (with O-ring): 85°C, All other models: 90°C.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DST P100 1/8-27 NPT: ⅛” NPT (M), DST P110 1/4-18 NPT: ¼” NPT (M), DST P140 1/2-14 NPT: ½” NPT (M), DST P100 R1/4: ¼” BSPT (M), DST P110 G1/2: ½” BSP (M), DST P140 G1/4A: ¼” BSP (M), DST P140 1/4-18 NPT: ¼” NPT (M), DST P140 G1/2: ½” BSP (M), DST P140 R1/4: ¼” BSPT (M), DST P146 1/4-18 NPT: ¼” NPT (M), DST P146 G1/2: ½” BSP (M), DST P140 G1/4 A (with O-ring): ¼” BSP (M).
Marking:
Danfoss, model and technical information on body
Installation Requirements:
R001
Expiry date:
31/03/2031
Model:
DST P100 1/8-27 NPT, DST P110 1/4-18 NPT, DST P140 1/2-14 NPT, DST P100 R1/4, DST P110 G1/2, DST P140 G1/4A, DST P140 1/4-18 NPT, DST P140 G1/2, DST P140 R1/4, DST P146 1/4-18 NPT, DST P146 G1/2, DST P140 G1/4 A (with O-ring).

Approval Holder:
Danfoss A/S
Company Name
Danfoss A/S
Address
Nordborgvej 81 6430 Nordborg
Country
Denmark
Phone
+74 88 22 22
General Email
danfoss@danfoss.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1584 of 1619

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.