Directory Search Results

Print List

#240455014

‘Corroless ACO Brush Grades RAL5005 (GB861) and Light Green (GB206)’ (formerly known as 'Acothane Brush Grades Blue & Green'). Site applied, blue or green coloured, two-part polyurethane coatings consisting of an amber coloured, liquid activator and blue or green coloured coating. Mix brush grade and activator in a 3.24:1 weight ratio. Apply as per technical data sheet dated Feb 2020. Cure for 14 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5042 Coatings, Paints & Linings
Section Subtitle:
Site applied pipe and fittings coatings. Compliance with BS6920 relates to the conditions of cure specified in the listing. If the cure conditions are varied from those described below then compliance with BS6920 cannot be assummed without further testing. Where catalysts are required, only tested catalysts in the recommended concentrations should be used. Manufacturer's advice must be sought if any non standard mixing or curing conditions are being considered.
WRAS Approval Number:
240455014
Expiry date:
30/04/2029

Approval Holder:
Axalta Coatings Systems Huthwaite UK Ltd.
Company Name
Axalta Coatings Systems Huthwaite UK Ltd.
Postcode
NG17 2RG

View All Listings by this Company

Print This Approval


#240255054

'Interline 975 White'. Site applied, two-part epoxy coating which can be applied as one coat or three coats. Mix parts A & B in a 2.2:1 and apply as per manufacturer's TDS 'Ref:4236', 'Issue Date: 04/02/2015'. When applied as a single coat, the coating must be cured for 14 days at 10°C. When applied as a three-coat system, the coating must be cured as follows: coat 1 = 24 hours@10 °C, coat 2 = 24 hours@10 °C & coat 3 = 14 days@10 °C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5042 Coatings, Paints & Linings
Section Subtitle:
Site applied pipe and fittings coatings. Compliance with BS6920 relates to the conditions of cure specified in the listing. If the cure conditions are varied from those described below then compliance with BS6920 cannot be assummed without further testing. Where catalysts are required, only tested catalysts in the recommended concentrations should be used. Manufacturer's advice must be sought if any non standard mixing or curing conditions are being considered.
WRAS Approval Number:
240255054
Expiry date:
28/02/2029

Approval Holder:
AkzoNobel - International Paint
Company Name
AkzoNobel - International Paint
Postcode
NE10 0LX

View All Listings by this Company

Print This Approval


#2312565

'Strongcoat EPW-P'. Site applied, two-component, light grey coloured (once applied) epoxy coating. Mix Part A (light grey coloured liquid) with Part B (orange coloured liquid) in a 8.1:3.78 volume ratio and apply coat 1 as per manufacturer's TDS 06-0020-A-2021. Cure for 24 hours@23°C. Mix and apply coat 2 in the same way as coat 1 and cure for 7 days@23°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5042 Coatings, Paints & Linings
Section Subtitle:
Site applied pipe and fittings coatings. Compliance with BS6920 relates to the conditions of cure specified in the listing. If the cure conditions are varied from those described below then compliance with BS6920 cannot be assummed without further testing. Where catalysts are required, only tested catalysts in the recommended concentrations should be used. Manufacturer's advice must be sought if any non standard mixing or curing conditions are being considered.
WRAS Approval Number:
2312565
Expiry date:
31/12/2028

Approval Holder:
DCP Saudi Co.
Company Name
DCP Saudi Co.
Address
Sulay Industrial Area, Istanbul St. Riyadh
Country
Saudi Arabia

View All Listings by this Company

Print This Approval


#2305561

‘Sika MonoTop®-1010’, one-part cementitious bonding primer for use with ‘Sika MonoTop®-615’ one-part cementitious repair mortar. Mix ‘Sika MonoTop®-1010’ with tap water in the ratio of 25kg:5.25 litres. Apply as per manufacturer’s Product Data Sheet ‘020302020010000054, March 2021, Version 01.01’. Mix ‘Sika MonoTop®-615’ with tap water in the ratio of 25kg:3.8 litres and apply immediately to ‘Sika MonoTop®-1010’ as per manufacturer’s Product Data Sheet ‘020302040030000198, December 2021, Version 02.02’. Cure for 21 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5063 Concrete, Cement and Mortar
Section Subtitle:
Repair materials. High humidity of 80% to 95% is required when curing cementitious materials.
WRAS Approval Number:
2305561
Expiry date:
31/05/2028

Approval Holder:
Sika Ltd.
Company Name
Sika Ltd.
Address
Watchmead, Welwyn Garden City, Hertfordshire
Postcode
AL7 1BQ
Country
United Kingdom
Phone
01707 394444
General Email
sales@uk.sika.com

View All Listings by this Company

Print This Approval


#2301541

'KS'. Grey coloured, hot press moulded GRP panel. For use with water up to 50°C.

Section:
5120 Glass Reinforced Plastics (GRP)
Section Subtitle:
Components.
WRAS Approval Number:
2301541
Expiry date:
31/01/2028

Approval Holder:
ES Metal Sdn. Bhd.
Company Name
ES Metal Sdn. Bhd.
Address
Lot 3, Jalan CJ5, Cheras Jaya Industrial Estate, Balakong, 43200 Selangor
Country
Malaysia

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1576 of 2250

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.