Range of WC pressure flushing valves with a solenoid valve controlling the flow. The valves are operated via an infra-red sensor or push-button assembly. The solenoid valve also incorporates a lever operated isolation valve. Maximum working pressure – 5.0 Bar. Cold water use only
Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.
Domestic hot water heat recovery unit incorporating a stainless-steel plate heat exchanger and cylinder. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.
"Greenstar" range of indirect heat interface units and "Flow 8000" (added December 2024) range of direct heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits. The "Greenstar" indirect models include a pressure relief valve (set at 3.0 bar) on the space (central) heating circuit. Greenstar models: Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary). Flow 8000 models (added December 2024): Maximum working pressure district and space heating 10.0 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary).
Water meter with a DZR brass body, stainless steel temperature sensors and EPDM ‘O’-rings. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meter manifolds with gun metal bodies and ball valve with either a quarter turn stop valve or screw down stop valve. The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Bypass valve assembly with a plastic body and push/pull operating method to switch flows between different outlets. The product incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Cold water use only.
Union ball, non-return valve with a plastic PVC body. Maximum working pressure 10.0 bar. Cold water use only.
Range of three or four-hole single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Four hole models Incorporate quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to a shower outlet.. Three hole models Incorporate a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. The product is supplied with a shower hose and shower handset. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of concealed thermostatic mixing valves with DZR brass bodies incorporating a thermostatic cartridge controlling the temperature. The inlets incorporate asingle check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of spout outlets with brass bodies (various finishes) incorporating an aerator. Product is supplied with either a lever type pop up (HIRONDELLE models) or click type waste (ICON-X & CORVAIR models). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
‘ECOCIRC XL N’ & ‘ECOCIRC XL PLUS N’ range of circulation pumps with stainless steel bodies, plastic impellers, and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (41491 & 41492 models) or 9.0 bar (41493 & 41494 models). Maximum operating temperature 65°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Range of shower outlets and shower kits. Shower outlets consisting of wall and ceiling mounted shower heads and hand shower. The inlets incorporate stainless steel flow regulators and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower kits can consist of shower hose, shower handset, riser rail and wall outlet elbow with bracket (depending on model). Shower handset inlet incorporates a stainless-steel strainer. Both the outlet of the wall elbow and inlet of shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Page 155 of 561
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.