Directory Search Results

Print List

#2311084

Range of WC dual flush drop valves with ABS bodies and silicone seals. The valves are operated via a two push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2311084
Size:
2” BSP (M)
Marking:
UK Bathrooms Ltd on body.
Installation Requirements:
R001 R571 R580 R581
Expiry date:
30/11/2028
Model:
B218M B228 B2650

Approval Holder:
UK Bathrooms Ltd
Company Name
UK Bathrooms Ltd
Address
Aston House Redburn Road Newcastle Upon Tyne
Postcode
NE5 1NB

View All Listings by this Company

Print This Approval


#2402803

Range of wall mounted, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel, pressure relief valve set at 3.0 bar and flow regulators. The inlets to both domestic hot water and primary circuits are controlled via screwdriver operated angled spherical valve. The primary circuit can be filled via a built in CAB device, that has been verified by test (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 80°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2402803
Size:
22mm Compression Primary 15mm Compression Secondary
Marking:
Worcester on label on the front panel. Serial number, model numbers and other technical information on adhesive labels on body and underside of the unit
Installation Requirements:
R001
Expiry date:
28/02/2029
Model:
Worcester Greenstar 8000 Style GR8700iW 30 C - Gas combi boiler 30kw, 14 plate heat exchanger 111/min, Worcester Greenstar 8000 Style GR8700iW 35 C - Gas combi boiler 35kw, 16 plate heat exchanger 131/min, Worcester Greenstar 8000 Style GR8700iW 40 C - Gas combi boiler 40kw, 18 plate heat exchanger 141/min, Worcester Greenstar 8000 Style GR8700iW 45 C - Gas combi boiler 45kw, 18 plate heat exchanger 151/min, Worcester Greenstar 8000 Style GR8700iW 50 C - Gas combi boiler 50kw, 20 plate heat exchanger 151/min. Worcester Greenstar 8000 Life GR8300iW 30 C - Gas combi boiler 30kw, 14 plate heat exchanger 111/min, Worcester Greenstar 8000 Life GR8300iW 35 C - Gas combi boiler 35kw, 16 plate heat exchanger 131/min, Worcester Greenstar 8000 Life GR8300iW 40 C - Gas combi boiler 40kw, 18 plate heat exchanger 141/min, Worcester Greenstar 8000 Life GR8300iW 45 C - Gas combi boiler 45kw, 18 plate heat exchanger 151/min, Worcester Greenstar 8000 Life GR8300iW 50 C - Gas combi boiler 50kw, 20 plate heat exchanger 151/min. Models added September 2024 Worcester Greenstar 8000+ GR8701iW 32 CB - Gas combi boiler 32kW, 16 plate heat exchanger 13 l/min Worcester Greenstar 8000+ GR8701iW 36 CB - Gas combi boiler 36kW, 16 plate heat exchanger 14 l/min Worcester Greenstar 8000+ GR8701iW 32 C - Gas combi boiler 32kW, 16 plate heat exchanger 13 l/min Worcester Greenstar 8000+ GR8701iW 36 C - Gas combi boiler 36kW, 16 plate heat exchanger 14 l/min Worcester Greenstar 8000+ GR8701iW 40 C - Gas combi boiler 40kW, 18 plate heat exchanger 15 l/min Worcester Greenstar 8000+ GR8701iW 45 C - Gas combi boiler 45kW, 18 plate heat exchanger 18 l/min Worcester Greenstar 8000+ GR8701iW 50 C - Gas combi boiler 50kW, 20 plate heat exchanger 21 l/min

Approval Holder:
Worcester Bosch
Company Name
Worcester Bosch
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
+44 1905 752761
General Email
ian.sharp@uk.bosch.com

View All Listings by this Company

Print This Approval


#2312904

Range of integrated water circuits with plastic bodies and EPDM ‘O’ rings and gaskets. The assemblies incorporate flow switches, plate heat exchangers and plastic flow regulators. The primary circuit incorporates a 3.0 bar rated pressure relief valve. Maximum working pressures: 2.5 bar primary circuit, 10.0 bar secondary circuit. Maximum operating temperature 85°C.

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
2312904
Size:
Secondary circuit: ½” BSP (M) inlet x F4 outlet. Primary circuit: ¾” BSP (M) inlet and outlet connections.
Marking:
Grundfos and Grundfos logo on primary circuit pump.
Installation Requirements:
R001 R008
Expiry date:
31/12/2028
Model:
IWC ICHS UPS/UPM2/3/4-xx v.xxx-xxx Where: UPS, UPM2, UPM3, UPM4 = pump type (primary circuit). -xx = pump max. head (UPS: 50, 60, 70. UPM2: 60, 70. UPM3: 20, 40, 45, 50, 60, 70, 75. UPM4: 20, 30, 40, 45, 50, 55, 60, 65, 70, 75). v.xxx-xxx = version number-free text, and can be any alphanumerical characters.
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#2311352

‘Wesan WP’ range of water meters with black epoxy coated cast iron bodies, plastic impellers and EPDM ‘O’-rings and seal. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1505 Water Meters
Size:
DN150- 200.
Marking:
WESAN, Diehl Metering, size, Year of manufacture (YYYY) and other technical information printed on dial face. Size, MWP and flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/11/2028
Model:
WESAN WP DN150, WESAN WP DN200.

Approval Holder:
Diehl Metering GmbH
Company Name
Diehl Metering GmbH
Address
Industriestrasse 13/Am Weimarer Berg 3, 91522 Ansbach/99510 Apolda
Country
Germany

View All Listings by this Company
Manufacturer:
Diehl Metering GmbH
Company Name
Diehl Metering GmbH
Address
Industriestrasse 13/Am Weimarer Berg 3, 91522 Ansbach/99510 Apolda
Country
Germany

View All Listings by this Company

Print This Approval


#2311063

Range of ultrasonic in-line water meters with brass bodies, inlets incorporating plastic strainers. Model (MA408 – DN25) incorporates a non-return valve (not suitable for backflow prevention) at the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Size:
¾”, 1”, 1¼” BSP male inlet and outlet.
Marking:
Kaifa logo, size, pressure and other technical information on faceplate.
Installation Requirements:
R001
Expiry date:
30/11/2028
Model:
MA408 – DN15, DN20, DN25.
Product Images

Approval Holder:
Shenzhen Kaifa Technology (Chengdu) Co., Ltd.
Company Name
Shenzhen Kaifa Technology (Chengdu) Co., Ltd.
Address
No 99 Tianquan Hi Tech Development Zone Chengdu PRC
General Email
xingweiyang@kaifa.com

View All Listings by this Company
Manufacturer:
Shenzhen Kaifa Technology (Chengdu) Co., Ltd.
Company Name
Shenzhen Kaifa Technology (Chengdu) Co., Ltd.
Address
No 99 Tianquan Hi Tech Development Zone Chengdu PRC
General Email
xingweiyang@kaifa.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1471 of 2222

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.