‘G5 CS’ command centre providing chilled or chilled sparkling water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The product incorporates a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The product is supplied with a filter cartridge. The inlet to the command centre incorporates two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum inlet supply pressure 5.0 bar. Cold water use only.
Range of combined isolation and drain off valves with brass bodies and EPDM O-rings. Maximum working pressure 16 Bar Maximum operating temperature 65°C
Non-metallic materials and components comply with BS6920 at 65°C
‘X086 Ceramic Dome’. Grey coloured, hydraulically pressed ceramic dome component. For use with water up to 23°C.
'Hilox 961'. Brown coloured, dry pressed ceramic material. For use with water up to 85°C.
'WHC1850'. White coloured, dry pressed ceramic disc. For use with water up to 85°C.
Page 130 of 189
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.