Directory Search Results

Print List

#250107701

'HYDRO MULTI-E' booster set range consisting of two to four electronically controlled pumps connected in parallel and mounted on a common base frame provided with all necessary fittings. The suction manifold incorporates an isolation valve fitted between it and the individual pumps, and a pressure switch with an isolation valve. The discharge manifold incorporates an isolation valve and a non-return valve (not suitable for backflow protection), which is fitted between it and the individual pumps, it also incorporates a combined isolation and drain valve. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250107701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
2” or 2½” BSPT (M). DN80 or DN100 flanged.
Marking:
Grundfos and Grundfos logo on pumps. Grundfos and Grundfos logo, type, Model, P/N no., Serial no., technical info, manufacturing country on adhesive label on pump base plate.
Installation Requirements:
R001 R415 R511
Expiry date:
31/01/2030
Model:
2” or 2½” BSPT (M): HYDRO MULTI-E “X” CRIE1-* x1 x2-x3-x4-x5-x6. HYDRO MULTI-E “X” CRIE3-* x1 x2-x3-x4-x5-x6. HYDRO MULTI-E “X” CRIE5-* x1 x2-x3-x4-x5-x6. 2½” BSPT (M) or DN80 flanged. HYDRO MULTI-E “X” CRIE10-* x1 x2-x3-x4-x5-x6. DN80 or DN100 flanged. HYDRO MULTI-E “X” CRIE15-* x1 x2-x3-x4-x5-x6. HYDRO MULTI-E “X” CRIE20-* x1 x2-x3-x4-x5-x6. The “X” preceding CR indicates the number of pumps in the booster set, between 2 and 4 pumps. CRIE1, CRIE3 and CRIE5 pumps: • Systems with 2 to 3 pumps = 2” threaded. • Systems with 4 pumps = 2½” threaded. CRIE10 pumps: • Systems with 2 pumps = 2½” threaded. • Systems with 3 to 4 pumps = DN80 flanges. CRIE15 and CRIE20 pumps: • Systems with 2 pumps = DN80 flanges. • Systems with 3 to 4 pumps = DN100 flanges. The number following the pump type designation (1, 3, 5, 10, 15 and 20) indicates the flow rate of the pump in m3/h. * The pumps are available with 1 to 36 impellers/stages (e.g. CRIE5-12 = 12 stages). x1 = U1, U2 or U8 relates to supply voltage (of no importance for drinking water). x2 = Design: A, B or C (of no importance for drinking water). x3 = Staring method: A (of no importance for drinking water). x4 = Product (country) range: A: International range. x5 = Material combination: A: Stainless steel manifold and base frame and standard valves. x6 = Options: A: Standard hydraulic.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#241107701

Self-priming single stage pump, with stainless steel body, plastic impellers, stainless steel shaft, NBR 'O'-rings and seals. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241107701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1” BSP (F).
Marking:
Grundfos and Grundfos logo on body. Grundfos and Grundfos logo, type, model number, product/version number, technical information, serial number and manufacturing location on adhesive label on motor housing.
Installation Requirements:
R001 R008 R415
Expiry date:
30/11/2029
Model:
99458789: JP 4-54 1X230V 50Hz 1,5M UK HU IE2.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#241204714

Dutypoint ‘VMV’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. VMV2, VMV3 and VMV4 pump sets are available with DN80 to DN150 manifolds depending on application. VMV5, VMV6, VMV7 and VMV8 pump sets are available with DN150 to DN200 manifolds, depending on application. The products incorporate spherical valves on both the suction and discharge manifolds, with expansion vessels, isolation valves, pressure gauges and transducers on the discharge manifolds only. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241204714
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN80 – DN200 Flanged connection
Marking:
Duty point, model and pressure on data label.
Installation Requirements:
R001 R415
Expiry date:
31/12/2029
Model:
VMV DN80 Versions twin, triple and quadruple pump units: VMV2-05, VMV2-07 and VMV2-10 – All motor sizes VMV3-05, VMV3-07 and VMV3-10 – All motor sizes VMV4-05, VMV4-07 and VMV4-10 – All motor sizes DN100 Versions: Twin, Triple and Quadruple Pump Units: VMV2-05, VMV2-07 and VMV2-10 – All motor sizes VMV3-05, VMV3-07 and VMV3-10 – All motor sizes VMV4-05, VMV4-07 and VMV4-10 – All motor sizes DN150 Versions: Twin, Triple and Quadruple Pump Units: VMV2-05, VMV2-20 and VMV2-25 – All motor sizes VMV3-05, VMV3-20 and VMV3-25 – All motor sizes VMV4-05, VMV4-20 and VMV4-25 – All motor sizes Units incorporating from 5 to 8 pumps (Models VMV5, VMV6, VMV7, VMV8): All units will feature DN150 – DN200 manifolds, size dependent on application. Key to Model Numbers: Example of Model Number: VMV2-15-V110 Range: VMV Number of pumps: 2 Nominal Flow rate (l/sec): 15 Inverter type e.g. ‘V’ for Vasco, or ‘H’ for Hydrovar Motor size (kW x 10)

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Unit A, Quedgeley West Business Park, Hardwicke, Gloucester
Postcode
GL2 4PA
Country
United Kingdom
Phone
01452313334
General Email
austin.hill@dutypoint.com

View All Listings by this Company

Print This Approval


#241202042

Range of overhead showers incorporating ABS (plastic bodies - various finishes), stainless steel strainer and flow restrictor (flow restrictor only on “minus flow” models) in the inlets. Open outlet use only. Maximum operating temperature 60.0°C

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
241202042
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (F)
Marking:
Solex on ball joint
Installation Requirements:
R001 R040
Expiry date:
31/12/2029
Model:
P22202-xx(minus flow) P24804-xx(minus flow) P29301-xx(minus flow) P22202-xx P24804-xx P29301-xx xx : different finishes CA: Chrome TH: Black VB: Golden C-TE: Gray Models with minus flow are fitted with a flow restrictor

Manufacturer:
Xiamen Solex High-Tech Industries Co., Ltd.
Company Name
Xiamen Solex High-Tech Industries Co., Ltd.
Address
No. 298 Yangguang Road West, Haicang District, Xiamen, Fujian Province, 361022
Country
China

View All Listings by this Company

Print This Approval


#241202048

Overhead shower outlet with brass body (available in various finishes). The inlet incorporates a plastic flow regulator. Maximum operating temperature: 75°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
241202048
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
Open Outlet use only.
Size:
½” BSP (F)
Marking:
SHS on body
Installation Requirements:
R001
Expiry date:
31/12/2029
Model:
V163W-XX & V663W-XX Where the product code suffix ‘XX’ denotes the surface finish. It will always be 2 or 3 digits, which can be any combination of numbers and/or letters. As examples: CP = chrome finish, URM = urban brass matt lacquered

Approval Holder:
Samuel Heath & Sons Plc
Company Name
Samuel Heath & Sons Plc
Address
100 Leopold Street Birmingham
Postcode
B12 0UJ
Country
United Kingdom
Phone
+44 (0) 1217 662 200
General Email
kay.stead@samuel-heath.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1235 of 1772

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.