#2307070

Range of dual flush WC drop valves with an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2307070
Size:
2’’ BSP (M)
Marking:
Nuie on body.
Installation Requirements:
R001 R571 R581
Expiry date:
31/07/2028
Model:
NUOU002 flush valve//Nuie Dual Flush WC Drop Valves

Approval Holder:
ROXOR GROUP
Company Name
ROXOR GROUP
Address
HAMNET HOUSE GIBBET STREET HALIFAX
Postcode
HX2 OAX

View All Listings by this Company

Print This Approval


#2309365

Range of under counter, vented, electric instantaneous (near boiling) water heaters with a stainless steel tank and silicone seals. Maximum operating temperature 98°C.

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2309365
Note:
Open outlet use only.
Size:
8mm pushfit.
Marking:
E-Tec on adhesive label on rear of body.
Installation Requirements:
R001 R040
Expiry date:
30/09/2028
Model:
B132001 (Grey), B100-B-XXX (Black), B100-W-XXX (White).
Product Images

Approval Holder:
Xiamen E-Tec Electric Shower Co., LTD
Company Name
Xiamen E-Tec Electric Shower Co., LTD
Address
No.11, HaiJing East 2nd Road, Xiamen Area of China (Fujian) Pilot Free Trade Zone.

View All Listings by this Company

Print This Approval


#2309362

SATK Series 22 range of wall-mounted direct heat interface units providing heating and instantaneous hot water. The hot water is generated via a plate heat exchanger. Maximum working pressure of all water circuits (secondary hot water, primary and space heating) 10.0 bar. Maximum operating temperature 90°C.

Section:
1460 Heaters
Section Subtitle:
Supplied from storage only, gas, thermal storage.
WRAS Approval Number:
2309362
Size:
¾” BSP (M)
Marking:
Caleffi on casing. Model, pressure and other technical information on adhesive label inside casing.
Installation Requirements:
R001 R140 R360
Expiry date:
30/09/2028
Model:
SATK22303 - Wall-mounted Direct Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 50kW. SATK22305 - Wall-mounted direct Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 60kW. SATK22307 - Wall-mounted direct Heat Interface Unit for Instantaneous domestic hot water production – For low temperature primary circuit.
Product Images

Approval Holder:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company

Print This Approval


#2309313

‘SATK 32’ range of indirect heat interface units providing instantaneous hot water. Domestic hot water is provided via a plate heat exchanger and this circuit incorporates a flow detector, stainless-steel filter and water hammer arrestor. The primary/space heating circuit incorporates a pressure relief valve set at 2.5 bar and an expansion vessel. Maximum working pressure of the domestic hot water circuit is 10.0 bar. Maximum working pressure of the primary circuit is 16.0 bar. Maximum working pressure of the space heating circuit is 2.5 bar. Maximum operating temperature 90°C.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2309313
Size:
¾” BSP (M).
Marking:
Caleffi and Caleffi logo moulded on face of unit. Caleffi, Caleffi logo, model number and technical info on data plate inside unit.
Installation Requirements:
R001 R140 R360
Expiry date:
30/09/2028
Model:
SATK32103 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 50kW. SATK32105 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 60kW. SATK32107 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 75kW.
Product Images

Approval Holder:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company

Print This Approval


#2309341

DZR brass elbow fitting. Compression connection to be used with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
2309341
Size:
½” captive nut x 15mm compression.
Marking:
Pintossi logo (letters ‘Pc’) and CR on body.
Installation Requirements:
R001
Expiry date:
30/09/2028
Model:
5624D 1/2xØ15 (Model no. 0562431215).
Product Images

Approval Holder:
PINTOSSI+C SPA
Company Name
PINTOSSI+C SPA
Address
VIA INDUSTRIALE 44 LUMEZZANE (BRESCIA) Italy
Postcode
25065
Country
Italy
Phone
+39 030 373 3138
General Email
alessandra@pintossi.it

View All Listings by this Company
Manufacturer:
PINTOSSI+C SPA
Company Name
PINTOSSI+C SPA
Address
VIA INDUSTRIALE 44 LUMEZZANE (BRESCIA) Italy
Postcode
25065
Country
Italy
Phone
+39 030 373 3138
General Email
alessandra@pintossi.it

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1222 of 2290

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.