Directory Search Results

Print List

#240102040

Range of in-line ultrasonic water meters with DZR brass bodies and a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.

Section:
1505 Water Meters
Size:
DN15 = ¾” BSP (M), DN20 = 1” BSP (M), DN25 = 1¼” BSP (M), DN32 = 1½” BSP (M).
Marking:
Hydrus, Saudi Meters Company, DN, PN, technical data and product information on meter face.
Installation Requirements:
R001
Expiry date:
31/01/2029
Model:
Hydrus range: 3092801 (DN15), 3092646 (DN20), 3092804 (DN25), 3092805 (DN32).
Product Images

Approval Holder:
SAUDI METERS COMPANY
Company Name
SAUDI METERS COMPANY
Address
2nd Industrial Area-4719, Riyadh 14331-7141, Unit # 14, Kingdom of Saudi Arabia

View All Listings by this Company
Manufacturer:
SAUDI METERS COMPANY
Company Name
SAUDI METERS COMPANY
Address
Street # 173, 2nd Industrial Area, P.O. Box 185, Riyadh 11383, Saudi Arabia

View All Listings by this Company

Print This Approval


#2302706

Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Size:
Flanged inlet/outlet: DN40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400.
Marking:
GAER, size, Model number and pressure rating and product info on dial face. Flow arrow & size on side of body,
Installation Requirements:
R001
Expiry date:
29/02/2028
Model:
WP-SDC GAER

Approval Holder:
Hidroglobal Tecnologia del Agua S.A.
Company Name
Hidroglobal Tecnologia del Agua S.A.
Address
C/ GARBÍ 3 Pol.Ind. Can Volart PARETS DEL VALLÈS
Postcode
08150
Country
Spain
Phone
+34 93 573 74 00
General Email
acalderon@regaber.com

View All Listings by this Company

Print This Approval


#240404044

Ultrims Ultrasonic range of in-line water meters with brass or plastic (-01 suffix models) bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Size:
UL 2.5 & UL 2.5-01 models: ¾” BSP (M). UL 4 & UL 4-01 models: 1” BSP (M). UL 6,3 model: 1¼” BSP (M). UL 25 model: DN50 flanged connection.
Marking:
Powogaz logo, manufacturer’s address and year (YYYY), CE Mark, meter type and other technical information on meter face. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
Ultrims range: UL 2.5 (port lengths 80, 110 & 165mm), UL 2.5-01 (port lengths 80 & 110mm), UL 4 (port lengths 105, 115, 130 & 190mm), UL 4-01 (port lengths 105 & 130mm), UL 6.3 (port lengths 165 & 260mm), UL 25 (port lengths 200, 270 & 300mm). Models added November 2024: Ultrims Range: UL10 (port length 260mm) UL16 (port length 300mm) Ultrims Neo Range: ULN2.5 (port lengths 80, 110, 115 & 165mm) ULN2.5-01 (port lengths 80, 110 & 165mm) ULN4 (port lengths 105, 115, 130 & 190mm) ULN4-01 (port lengths 105, 115 & 130mm) Models Added April 2025: Ultrimis Neo 6,3 Ultrasonic water meter with brass body. DN25 - Body length [mm]: 165, 260 - G1 ¼ B. Ultrimis Neo 10 Ultrasonic water meter with brass body. DN32 - Body length [mm]: 260 - G1 ½ B Ultrimis Neo 16 Ultrasonic water meter with brass body. DN40 - Body length [mm]: 300 - G2 B Ultrimis Neo 25 Ultrasonic water meter with brass body. DN50 - Body length [mm]: 200, 270, 300 – flanged.
Product Images

Approval Holder:
Apator Powogaz S.A.
Company Name
Apator Powogaz S.A.
Address
Jaryszki 1c Jaryszki
Postcode
62-023 Żerniki
Country
Poland
Phone
+48 789 454 593
General Email
przemyslaw.gretka@apator.com

View All Listings by this Company
Manufacturer:
Apator Powogaz S.A.
Company Name
Apator Powogaz S.A.
Address
Jaryszki 1c Jaryszki
Postcode
62-023 Żerniki
Country
Poland
Phone
+48 789 454 593
General Email
przemyslaw.gretka@apator.com

View All Listings by this Company

Print This Approval


#240202009

Range of pressure reducing valve assemblies with brass bodies incorporating spherical stop valve, pressure gauge and double check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). Models TVAP250001 & TVAP250005 also incorporate a water meter port. Maximum supply pressure 16 bar. Outlet pressure setting is adjustable in the range 1.5 to 6 bar. Maximum operating temperature 65°C

Section:
1510 Water Meter Manifolds
Size:
See Model
Marking:
Reliance logo, size, PN, DR cast into body Pressure, maximum temperature and reliance on body of PRV.
Installation Requirements:
R001
Expiry date:
28/02/2029
Model:
TVAP250001 ¾” BSP (F) x ¾” BSP (F) TVAP250005 1” BSP (F) x 1” BSP (F) TVAP250050 ¾” BSP (F) x ¾” BSP (F) TVAP250055 1” BSP (F) x 1” BSP (F)
Product Images

Approval Holder:
RELIANCE WORLDWIDE CORPORATION (UK) LTD
Company Name
RELIANCE WORLDWIDE CORPORATION (UK) LTD
Address
HORTON ROAD WEST DRAYTON
Postcode
UB7 8JL
Country
United Kingdom
Phone
+44 7730 052060
General Email
PETER.LANCASTER@RWC.COM

View All Listings by this Company

Print This Approval


#2310315

Hydraulic circuit used to control the water path within the heating and sanitary boiler, with plastic body incorporating filter, flow regulator, plate heat exchanger and EPDM O-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 85°C.

Section:
1530 Miscellaneous Fittings
Size:
¾”BSP(M) x ½”BSP(M).
Marking:
Company logo on body (CHUNHUi)
Installation Requirements:
R001 R008
Expiry date:
31/10/2028
Model:
FUSION ASTRO- Engineering Plastics Hydraulic Circuit.
Product Images

Approval Holder:
THE ELECTRIC HEATING COMPANY LTD
Company Name
THE ELECTRIC HEATING COMPANY LTD
Address
Block 5, Unit 40 Third Road Blantyre Ind Est GLASGOW
Postcode
G72 0UP
Country
United Kingdom
Phone
07986970466
General Email
chris@electric-heatingcompany.co.uk

View All Listings by this Company
Manufacturer:
Zhejiang Chunhui Intelligent Control Co Ltd
Company Name
Zhejiang Chunhui Intelligent Control Co Ltd
Address
No. 288 Chunhui Industrial Rd. Shangyu, Zhejiang
Country
China
General Email

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 114 of 199

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.