Range of stainless-steel expansion joints with flanged or threaded end connections. For maximum working pressure please refer to model. Maximum operating temperature 100°C.
Range of Indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 90˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check cartridge, verified by test (suitable for backflow protection against fluid category 2) an expansion vessel and tundish. Maximum working pressure: Secondary: 4.0 Bar Primary: 3.0 Maximum operating temperature 99.0°C
Range of primary hot water buffer tanks consisting of stainless steel shells. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of air venting valves incorporating an epoxy coated, iron body and a drain point. Maximum working pressure 16.0 bar. Maximum operating temperature 60˚C.
Range of air venting valves with a stainless-steel bodies and springs, plastic float and EPDM ‘O’-rings. Maximum working pressure 25.0 Bar. Maximum operating temperature 80.0°C.
Page 105 of 201
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.