#2212019

Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings.

Section:
1863 Tubes
Section Subtitle:
Elastomeric.
WRAS Approval Number:
2212019
Size:
½" BSP (F) conical nut end connections.
Marking:
Jetom, WRAS, and date of manufacture (YYYY.M.D) on end connector.
Installation Requirements:
R001
Expiry date:
31/12/2027
Model:
H3DFG-XXXX01C & H3DFG-XXXX68C With XXXX denoting length 20-200cm.
Product Images

Approval Holder:
Quanzhou Jetom Hose Industry Co.,Ltd
Company Name
Quanzhou Jetom Hose Industry Co.,Ltd
Address
No. 1, South Road, High-tech Industrial Park, Luncang Town, Nan'an City, Fujian

View All Listings by this Company

Print This Approval


#2210057

Range of stainless steel indirect (single or twin coil), direct and heat pump unvented hot water storage cylinders. The heat pump models also incorporate a plate heat exchanger and a circulation pump. The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@90.0˚C. The products are supplied with an inlet control group consisting of an adjustable pressure reducing valve, adjustable in the range of 0.8 bar - 6.0 bar, but factory pre-set at 3.0 bar, a strainer, am expansion relief valve set at 6.0 bar and an approved single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The products are also supplied with an immersion heater, an expansion vessel (12, 19 or 24 litres depending on model) and a tundish. Maximum supply pressure to the inlet control group: 16.0 bar. Maximum working pressure: Secondary circuit: 5.5 Bar. Primary Circuit: 6.0 Bar (All models except for the Direct - DI prefix models). Maximum operating temperature 75°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2210057
Note:
R008 only applies to the HP prefix (Heat Pump) models. Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression or 28mm stub (Heat Pump models only).
Marking:
WARMFLOW logo, capacity, model name, maximum pressure, maximum temperature, date of manufacture (month/YYYY) and other technical info on adhesive label on body.
Installation Requirements:
R001 R008 R360
Expiry date:
31/10/2027
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°C and 45°C.
Model:
DI110UV - Direct Unvented water cylinder, DI140UV - Direct Unvented water cylinder, DI170UV - Direct Unvented water cylinder, DI200UV - Direct Unvented water cylinder, DI240UV - Direct Unvented water cylinder, DI290UV - Direct Unvented water cylinder. IN110UV - Indirect Unvented water cylinder, IN140UV - Indirect Unvented water cylinder, IN170UV - Indirect Unvented water cylinder, IN200UV - Indirect Unvented water cylinder, IN240UV - Indirect Unvented water cylinder, IN290UV - Indirect Unvented water cylinder. C140UV - Indirect Unvented water cylinder, C170UV - Indirect Unvented water cylinder, C200UV - Indirect Unvented water cylinder. TW170UV - Twin coil indirect Unvented water cylinder, TW200UV - Twin coil indirect Unvented water cylinder, TW240UV - Twin coil indirect Unvented water cylinder, TW290UV - Twin coil indirect Unvented water cylinder. HP170UV - Heat pump indirect unvented water cylinder, HP200UV - Heat pump indirect unvented water cylinder, HP240UV - Heat pump indirect unvented water cylinder, HP290UV - Heat pump indirect unvented water cylinder.
Product Images

Approval Holder:
Warmflow Engineering Co. Ltd
Company Name
Warmflow Engineering Co. Ltd
Address
Lissue Industrial Estate, Moira Road, Lisburn Northern Ireland
Phone
02892 62 1515
General Email
sales@warmflow.co.uk

View All Listings by this Company
Manufacturer:
Warmflow Engineering Co. Ltd
Company Name
Warmflow Engineering Co. Ltd
Address
Lissue Industrial Estate, Moira Road, Lisburn Northern Ireland
Phone
02892 62 1515
General Email
sales@warmflow.co.uk

View All Listings by this Company

Print This Approval


#2212327

Range of automatic air venting valves with brass bodies, stainless steel strainer, plastic float and EPDM ‘O’-rings and gaskets. Maximum working pressure 16.0 bar.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1980 Valves
Section Subtitle:
Air venting. Fittings in this section are suitable for above ground installations only.
WRAS Approval Number:
2212327
Size:
see model
Marking:
Yuhuan Zhengqu Fluid Intelligence Control Co., Ltd.logo, size and date of manufacture (YY-MM) on body.
Installation Requirements:
R001
Expiry date:
31/12/2027
Model:
6036-15-00: ½" BSP (M), 6036-25-00: 1" BSP (M).
Product Images

Approval Holder:
Yuhuan Zhengqu Fluid Intelligence Control Co., Ltd.
Company Name
Yuhuan Zhengqu Fluid Intelligence Control Co., Ltd.
Address
Bingang Industrial City, Shamen Town, Yuhuan City Zhejiang Province
Country
China

View All Listings by this Company
Manufacturer:
Yuhuan Zhengqu Fluid Intelligence Control Co., Ltd.
Company Name
Yuhuan Zhengqu Fluid Intelligence Control Co., Ltd.
Address
Bingang Industrial City, Shamen Town, Yuhuan City Zhejiang Province
Country
China

View All Listings by this Company

Print This Approval


#2301005

Range of air release valves with blue epoxy coated ductile iron bodies and EPDM seats. Maximum working pressure 16.0 bar

Non-metallic materials and components comply with BS6920 at 80°C

Section:
1980 Valves
Section Subtitle:
Air venting. Fittings in this section are suitable for above ground installations only.
WRAS Approval Number:
2301005
Size:
DN50, DN80, DN100, DN150, DN200, DN300 flanged.
Marking:
AFC) Suzhou Alpine Flow Control Co., Ltd Logo, DN, PN and other technical Info on body.
Installation Requirements:
R001 R120
Expiry date:
31/01/2028
Model:
KARX series
Product Images

Approval Holder:
Suzhou Alpine Flow Control Co Ltd
Company Name
Suzhou Alpine Flow Control Co Ltd
Address
B5 Chao Yang Factroy Caohu Industrial Park Xiangcheng Economic Development Zone
Country
Suzhou

View All Listings by this Company
Manufacturer:
Suzhou Alpine Flow Control Co Ltd
Company Name
Suzhou Alpine Flow Control Co Ltd
Address
B5 Chao Yang Factroy Caohu Industrial Park Xiangcheng Economic Development Zone
Country
Suzhou

View All Listings by this Company

Print This Approval


#2212070

Range of wall mounted concealed blending valves with brass bodies. Incorporating a thermostatic mixing valve with a single lever operating member controlling the temperature to 2 separate outlets. The product incorporates approved single check valves on the inlets; however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 Bar

Non-metallic materials and components comply with BS6920 at 60°C

Section:
2000 Shower Valves
Section Subtitle:
Shower valve(s) with manual temperature control.
WRAS Approval Number:
2212070
Size:
¾” BSP (F)
Marking:
Volevatch on face plate
Installation Requirements:
R001 R010 R040
Expiry date:
31/12/2027
Model:
B/RM-T2-01 P/RM-T2-01
Product Images

Approval Holder:
VOLEVATCH
Company Name
VOLEVATCH
Address
1 BIS PLACE JEAN JAURES 80130 TULLY
Country
FRANCE

View All Listings by this Company
Manufacturer:
VOLEVATCH
Company Name
VOLEVATCH
Address
1 BIS PLACE JEAN JAURES 80130 TULLY
Country
FRANCE

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1012 of 2264

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.