Section Code 1510 :
Back To Directory SectionsRange of pressure reducing valve assemblies with brass bodies incorporating spherical stop valve, pressure gauge and double check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). Models TVAP250001 & TVAP250005 also incorporate a water meter port. Maximum supply pressure 16 bar. Outlet pressure setting is adjustable in the range 1.5 to 6 bar. Maximum operating temperature 65°C
Water meter manifold assembly with gunmetal body, incorporating a servicing valve and a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Max operating pressure 16 bar Maximum operating temperature Cold water only
Range of water meter housings. The 4414-WMH-20 (threaded) model has a DZR brass body and a check valve cartridge on the inlet verified by test (suitable for backflow protection against Fluid Category 2). The 4414-WMH-1 & 4414-WMH-2 (compression) models have a brass body and an approved check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection. The compression models are for use with copper pipe (manufactured to EN 1057). Maximum operating pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meter housings incorporating DZR brass bodies and a check valve cartridge however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum operating pressure 16 bar. Maximum operating temperature 85°C
Range of water meter manifolds incorporating an isolation valve, housed in a meter box. For use with PE80 pipe to BS EN 12201. Maximum working pressure 16 bar. Cold water use only.
Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201). The inlets incorporate a spherical valve and a check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201). The inlet incorporates a stop valve. Model MB77025AM Matrix Single (CV) incorporates a single check valve cartridge and model MB77025DCV Matrix Dual (DCV) incorporates two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies. The inlets incorporate a stop valve. Model MB77025CG Matrix Single (CV) incorporates a single check valve cartridge and model MB77025CGDCV Matrix Dual (DCV) incorporates two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201) and copper pipe. The products incorporate a drain off valve, plastic strainer and a single check valve cartridge however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve. Models ending in ‘CGDM’ incorporate a single check valve cartridge and models ending in ‘CGDCVDM’ incorporate two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies, incorporating plastic pushfit inlets and plastic pushfit outlets. The inlets incorporate a spherical ball valve. Models MB40408256DCVDM & MB40408254DCVDM incorporate two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16 bar. Cold water use only.
Range of water meter manifolds with plastic bodies, incorporating plastic inlets and gunmetal outlets. The inlets incorporate a spherical ball valve. Models MB40408036CGDCVM & MB40408034CGDCVM incorporate two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16 bar. Cold water use only.
Range of water meter manifolds incorporated into a meter chamber. The inlet of all models incorporates an isolation valve and an approved check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. MK7000003003 is for use with MDPE plastic pipe (manufactured to BS EN 12202-1:2011). Maximum working pressure 12.5 bar. Cold water use only.
Water meter manifold with a gunmetal body. The product incorporates a non-return valve (not suitable for backflow protection) and a spherical valve on the inlet. Maximum working pressure 16.0 bar. Cold water use only.
Page 2 of 2
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.