Section Code 2345 : Special combination assemblies.
Back To Directory SectionsRange of pressure reducing valve assemblies with DZR brass bodies incorporating a spherical valve, a pressure gauge and 2 inline check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). Models TVAP250001 & TVAP250005 also incorporate a water meter port. Maximum supply pressure 16 bar. Outlet pressure setting is adjustable in the range 1.5 to 6 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Tenant valve assemblies with a DZR brass body consisting of water meter manifold, servicing valve and a pressure reducing valve (adjustable between 1.0 and 6.0 bar). The inlet incorporates two approved check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure 16.0 bar.
‘Satefy group’ with a brass inlet and a DZR brass body which incorporates a lever operated spherical valve, followed by an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and a plastic bodied pressure relief valve (set at 6.0 bar). The product incorporates a test point. The compression connections are for use copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of cold-water inlet control groups consisting of an in-line, manually adjustable pressure reducing valve and a pressure relief valve pre-set at either 6.0 or 8.0 bar, housed within DZR brass bodies. The products incorporate approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. The pressure reducing valves also have stainless-steel strainers. Maximum inlet pressure 16.0 bar. Cold water use only. CWIC351300 – Outlet pressure range 1.0 to 3.5 bar. Pressure relief valve set at 6.0 bar CWIC351301 – Outlet pressure range 1.0 to 2.1 bar. Pressure relief valve set at 8.0 bar. CWIC351303 – Outlet pressure range 1.0 to 3.5 bar. Pressure relief valve set at 8.0 bar CWIC351306 – Outlet pressure range 1.5 to 6.0 bar. Pressure relief valve set at 8.0 bar
Inlet control group with a DZR brass body, consisting of a pressure reducing valve and pressure relief valve (6.0 Bar). The inlet incorporates a stainless-steel strainer, and the outlet incorporates an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The product is for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C. Outlet pressure range of the pressure reducing valve is 1.0 to 4.0 bar.
Page 2 of 2
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.