Range of wall mounted single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a touchless operation method which operates a solenoid valve which controls the flow and is connected via a hose to the spout outlet. The spout outlets incorporate a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Wall mounted two hole, metal, single outlet (fixed) combination tap assembly (brass body in various finishes - see model), incorporating a 2 way ceramic disc diverter controlling the flow between the spout outlet and the shower outlet with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. The spout outlet incorporates a plastic aerator. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a touchless operation method which operates a solenoid valve which controls the flow and is connected via a hose to the spout outlet. The spout outlets incorporate a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic blending valve (chromium plated brass) incorporating ceramic disc headwork controlling the flow. Temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The product is supplied with dome type operating members. The inlets incorporate a stainless steel strainer and single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wastewater heat recovery systems incorporating stainless steel corrugated pipe. Maximum working pressure 16.0 bar. Cold water use only.
Range of wall mounted shower elbows with brass bodies (chrome plated) incorporating single check valves cartridges fitted on the outlet (however, the complete product has not been fully tested to demonstrate it provides backflow protection).Maximum operating temperature 65°C.
Range of shower arms with a brass body and various finishes. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass body with various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with a pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Bath spout incorporating a brass body (various finishes), EPDM ‘O’-rings and a plastic flow straightener. Maximum operating temperature 60°C
Wall mounted two-hole, single outlet (fixed) combination tap assembly with a brass body (chrome trim set) incorporating a ceramic cartridge headwork and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of shower kits, shower outlets and shower hoses. The shower handsets and overhead shower inlets incorporate a plastic flow regulator. Maximum operating temperature 45°C.
Shower bracket, incorporating a brass body(various finishes) and EPDM O’-rings. Maximum operating temperature 85°C.
Isolation elbow, incorporating brass bodies (chrome plated) and brass ball (chrome plated), EPDM O-rings and a PTFE seal. The product is supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C
Two hole, single outlet (fixed) combination tap assembly with brass body (various finishes). Incorporating quarter turn ceramic disc headworks, and self cancelling diverter to shower outlet. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of overhead shower outlets incorporating metal bodies (various finishes) and flow regulator and strainer on the inlets. Maximum operating temperature 43°C.
Range of shower kits, comprosing of shower handset, shower hose, riser rail and overhead shower outlet depending on kit. Inlets incorporate a flow regulator (models 1.1740.578 & 1740.155) Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly with brass body (chrome plated), incorporating single sequential headwork with single lever operating member. The inlets incorporate a screwdriver operated servicing valve and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) concealed combination tap assembly with brass body (chrome plated), incorporating a single sequential headwork with single lever operating member. The inlets incorporate a screwdriver operated servicing valve and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Page 4 of 7
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.