#240707001

‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only. ‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240707001
Size:
Small Booster Sets Systems with 2 to 3 Pumps = 2” BSP (M), Systems with 4 to 6 pumps = 2½” BSP (M). Medium Booster Sets Systems with CRI(E)10 pumps: Systems with 2 to 3 pumps = 2½” BSP (M), Systems with 4 to 5 pumps = DN80 flanges, Systems with 6 pumps = DN100 flanges. Systems with CRI(E)15 and CRI(E)20 pumps: Systems with 2 pumps = DN80 flanges, Systems with 3 to 4 pumps = DN100 flanges, Systems with 5 to 6 pumps = DN150 flanges. Sizes added November 2024: Large Booster Sets Systems with CR(E)32 pumps: Systems with 2 pumps = DN100 flanges, Systems with 3 to 6 pumps = DN150 flanges. Systems with CR(E)45 and CR(E)64 pumps: Systems with 2 pumps = DN150 flanges, Systems with 3 to 6 pumps = DN200 flanges.
Marking:
Grundfos logo, model, serial number, P/N, manufacturing country and technical information on adhesive label on base frame.
Installation Requirements:
R001 R008 R415
Expiry date:
31/07/2029
Model:
Small Booster Sets (PN16): HYDRO MPC-E “X” CRIE3, HYDRO MPC-E “X” CRIE5, HYDRO MPC-F “X” CRI3, HYDRO MPC-F “X” CRI5, HYDRO MPC-S “X” CRI3, HYDRO MPC-S “X” CRI5. Medium Booster Sets (PN16): HYDRO MPC-E “X” CRIE10, HYDRO MPC-E “X” CRIE15, HYDRO MPC-E “X” CRIE20, HYDRO MPC-F “X” CRI10, HYDRO MPC-F “X” CRI15, HYDRO MPC-F “X” CRI20, HYDRO MPC-S “X” CRI10, HYDRO MPC-S “X” CRI15, HYDRO MPC-S “X” CRI20. Models added November 2024: Large Booster Sets (PN16): HYDRO MPC-E “X” CRE32, HYDRO MPC-E “X” CRE45, HYDRO MPC-E “X” CRE64, HYDRO MPC-F “X” CR32, HYDRO MPC-F “X” CR45, HYDRO MPC-F “X” CR64, HYDRO MPC-S “X” CR32, HYDRO MPC-S “X” CR45, HYDRO MPC-S “X” CR64. The “X” preceding CR indicates the number of pumps in the booster set, between 2 and 6 pumps. The number following the pump type designation (e.g.: 32, 45 and 64) indicates the flow rate of the pump in m³/h. Full code example: Hydro MPC-E 2 CRE32-2-U2D-A-A-GHJ Where: Hydro MPC = Product name. -E = System type; All pumps with E-motor or CUE, and can also be -F for Fixed-speed pumps, 1 CUE or -S for Fixed-speed pumps. 2 = Number of pumps, this can be any number between 2 and 6. CRE = Pump type, can also be pumps beginning CR, CRI or CRIE. 3, 5, 10, 15, 20, 32, 45, 64 = flow rate of the pump in m³/h. U2 = Voltage, can also be U1, U3, U4, U5, U6, U7, U8, U9, UA, UB, UC, UD or UX. D = Design, can also be A, B, C, E, F, G, H, I or W. -A = Starting method; E (speed control). -A = Material combination; Stainless steel manifold, base frame and standard valves. -HJ = Options;, H - Dry-running protection, J - Redundant sensor.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#241002709

Range of vertical (CVM) or horizontal (CHM) multistage pumps with stainless-steel bodies and stainless-steel impellers, intermediate chambers, shaft and outer sleeve and EPDM seals. Maximum working pressure: 25 Bar. Maximum working temperature: 23°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241002709
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See models below.
Marking:
Groundfos Logo, D.O.M (YYYY.MM.DD), series number, max temp, max pressure and other information on data plate on body. Flow arrow on body
Installation Requirements:
R001 R415
Expiry date:
31/10/2029
Model:
CV(H)M 4: 2 to 12 stages: Suction flange – DN50, Discharge flange – DN20. CV(H)M 5: 2 to 12 stages: Suction flange – DN50, Discharge flange – DN40. CV(H)M 6: 2 to 11 stages: Suction flange – DN65, Discharge flange – DN40. CV(H)M 10: 2 to 10 stages: Suction flange – DN100, Discharge flange – DN80.
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#241207701

‘UPM10’ and ‘UPM20’ range of circulator pumps with a stainless-steel body, plastic impellor and EPDM ‘O’-rings. The product is supplied with EPDM gaskets for the inlet and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241207701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1½” BSP (M) inlet/outlet.
Marking:
Grundfos and Grundfos logo, type and model on nameplate on motor housing. P/N no., P/C no., Serial (S/N) no., technical info, manufacturing country and data matrix on end of motor housing. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
31/12/2029
Model:
UPM 10M 25-95 N 180, UPM 10L 25-105 N 180, UPM 10XL 25-125 N 180, UPM 20S 25-145 N 180. Where: Pump type: UPM 10M, UPM 10L, UPM 10XL, UPM 20S. Control variant: []: PWM, LIN: LIN bus input signal, 0-10V, AUTO, HYBRID, SOLAR, DHW. Nominal diameter: 25: G 1½”. Max. Head: 95: 9.5m, 105: 10.5m, 125: 12.5m, 145: 14.5m. Designation/Pump housing: N 180: Stainless steel body, 180mm port to port length. Control box orientation: 3: 3 o’clock (right), 6: 6 o’clock (below), 9: 9 o’clock (left). Customer code: XXX (no impact on water contact parts).
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#250107701

'HYDRO MULTI-E' booster set range consisting of two to four electronically controlled pumps connected in parallel and mounted on a common base frame provided with all necessary fittings. The suction manifold incorporates an isolation valve fitted between it and the individual pumps, and a pressure switch with an isolation valve. The discharge manifold incorporates an isolation valve and a non-return valve (not suitable for backflow protection), which is fitted between it and the individual pumps, it also incorporates a combined isolation and drain valve. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250107701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
2” or 2½” BSPT (M). DN80 or DN100 flanged.
Marking:
Grundfos and Grundfos logo on pumps. Grundfos and Grundfos logo, type, Model, P/N no., Serial no., technical info, manufacturing country on adhesive label on pump base plate.
Installation Requirements:
R001 R415 R511
Expiry date:
31/01/2030
Model:
2” or 2½” BSPT (M): HYDRO MULTI-E “X” CRIE1-* x1 x2-x3-x4-x5-x6. HYDRO MULTI-E “X” CRIE3-* x1 x2-x3-x4-x5-x6. HYDRO MULTI-E “X” CRIE5-* x1 x2-x3-x4-x5-x6. 2½” BSPT (M) or DN80 flanged. HYDRO MULTI-E “X” CRIE10-* x1 x2-x3-x4-x5-x6. DN80 or DN100 flanged. HYDRO MULTI-E “X” CRIE15-* x1 x2-x3-x4-x5-x6. HYDRO MULTI-E “X” CRIE20-* x1 x2-x3-x4-x5-x6. The “X” preceding CR indicates the number of pumps in the booster set, between 2 and 4 pumps. CRIE1, CRIE3 and CRIE5 pumps: • Systems with 2 to 3 pumps = 2” threaded. • Systems with 4 pumps = 2½” threaded. CRIE10 pumps: • Systems with 2 pumps = 2½” threaded. • Systems with 3 to 4 pumps = DN80 flanges. CRIE15 and CRIE20 pumps: • Systems with 2 pumps = DN80 flanges. • Systems with 3 to 4 pumps = DN100 flanges. The number following the pump type designation (1, 3, 5, 10, 15 and 20) indicates the flow rate of the pump in m3/h. * The pumps are available with 1 to 36 impellers/stages (e.g. CRIE5-12 = 12 stages). x1 = U1, U2 or U8 relates to supply voltage (of no importance for drinking water). x2 = Design: A, B or C (of no importance for drinking water). x3 = Staring method: A (of no importance for drinking water). x4 = Product (country) range: A: International range. x5 = Material combination: A: Stainless steel manifold and base frame and standard valves. x6 = Options: A: Standard hydraulic.
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#241107701

Self-priming single stage pump, with stainless steel body, plastic impellers, stainless steel shaft, NBR 'O'-rings and seals. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241107701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1” BSP (F).
Marking:
Grundfos and Grundfos logo on body. Grundfos and Grundfos logo, type, model number, product/version number, technical information, serial number and manufacturing location on adhesive label on motor housing.
Installation Requirements:
R001 R008 R415
Expiry date:
30/11/2029
Model:
99458789: JP 4-54 1X230V 50Hz 1,5M UK HU IE2.
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#250307701

“TP/TPE series 100” single stage centrifugal pumps, incorporating cast iron (with black coloured electrocoating) or stainless-steel bodies and plastic impellers. Maximum working pressure: Cast iron models: 16.0 bar, Stainless steel models: 10.0 bar. Maximum operating temperature: Cast iron models: 60°C, Stainless steel models: 85°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250307701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1½”-2” BSP (M) inlet/outlet. DN40 Flanged inlet/outlet.
Marking:
Grundfos and Grundfos logo, type, model, product no., technical info and manufacturing country on data plate. Grundfos and Grundfos logo on motor. Flow arrow on body.
Installation Requirements:
R001 R415
Expiry date:
31/03/2030
Model:
TP(E)100 series: TP (E) XX-XXX/2 A or AI or X - F or O - A or I - XXXX Where: TP = pump type with normal Asynchronous motor. TPE = pump type with E-motor (motor with integrated frequency driver). XX = nominal DN size of inlet/outlet ports (25 - 40). XXX = maximum head (dm) (50 - 90). /2 = pole number. A or AI or X = A: Basic version, AI: PN6 flange, X: Special Version. F or O = F: DIN Flanged, O: Union (threaded). A or I = A: Basic Version. Cast iron pump housing and motor stool, I: S/Steel pump housing and motor stool. XXXX = shaft seal type - BQQE or BQBE. YYY = coding for motor. E.g. TP (E) 32-60/2 A-F-A-BQQE-CX1
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#250307702

“TPE 2 & TPE3 series” single stage centrifugal pumps, incorporating cast iron (with black coloured electrocoating) or stainless-steel bodies and plastic impellers. Maximum working pressure 10.0 bar. Maximum operating temperature: Cast iron models: 60°C, Stainless steel models: 85°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250307702
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Cast iron models: DN32 - DN100 Flanged inlet/outlet. Stainless steel models: DN32 - DN65 Flanged inlet/outlet.
Marking:
Grundfos and Grundfos logo, type, model, product no., technical info and manufacturing country on data plate. Grundfos and Grundfos logo on control unit.
Installation Requirements:
R001 R415
Expiry date:
31/03/2030
Model:
TPE2/3 series: TPE 2 or 3 (E) XX-XXX S or N - A or AI or X - F - A or I - XXXX - YYY Where: TPE2 = pump type with normal Asynchronous motor. TPE3 = pump type with E-motor (motor with integrated frequency driver). XX = nominal DN size of inlet/outlet ports (cast iron 32 - 100, S/Steel 32 - 65). XXX = maximum head (dm). S or N = S: Built-in differential-pressure and temperature sensor (TPE3 models), N: Without built-in sensor (TPE2 models). A or AI or X = A: Basic version, AI: PN6 flange, X: Special Version. F = DIN Flanged. A or I = A: Basic Version. Cast iron pump housing and motor stool, I: S/Steel pump housing and motor stool. XXXX = shaft seal type - BQQE or BQBE. YYY = coding for motor. E.g. TPE3 100-120 S-X-F-A-BQQE-GAB
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 4

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.