Grundfos Holding A/S Approvals


#2305911

Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2305911
Expiry date:
31/05/2028
Size:
CPS/ITS/LPS/RPS: BRASS CW 617N: ¼" BSPP (M). S/S EN 14408: ½" BSPP (M) w/vent port. ½" BSPT (M). ½" BSPT (M) (short). ½" NPT (M). Plastic: ⅜" BSPP (M). DPS: BRASS CW 617N: ½" BSPT (M) w/vent hole. 15.5mm w/vent hole. S/S EN 1.4401: ½" BSPT (M) w/vent hole. ½" BSPP (M). Housing only S/S (EN 1.4408): 2x ⅛" NPT (F). End connections for housing only: AISI 316 6mm compression, 6mm and 8mm tube. MFS, VFS (COMPOSITE FLOWPIPE): FLOWPIPE ONLY: 1”, 1¼”, 1½” BSPP (M). END CONECTIONS: BRASS CW 617N: ½", ¾" BSPP (M). ¾", 1", 1¼" BSPT (M). ½", ¾", 1", 22mm, 28mm SWEAT. S/S EN 1.4401: ¾", 1", 1¼" NPT (M). 1", 1¼" BSPT (M). MFS, VFS (S/STEEL FLOWPIPE): FLOWPIPE ONLY (EN 1.4408): ¾", 1", 1¼" BSPP (M). ¾", 1", 1¼" NPSM (M). 1" FLANGE. END CONNECTIONS: BRASS CW 617N: ½", ¾", 1" BSPT (M). ¾", 1", 22mm & 28mm SWEAT. S/S EN 1.4401: ¾", 1" BSPT (M). ¾", 1" NPT (M). VFI: CAST IRON OR S/STEEL EN 1.4408 FLANGED: DN18/25/32 (1¼"). DN40/50 (2"). DN65/80/100. S/S EN 1.4401: 1”, 1¼" BSPT (M). 1, 1¼" NPT (M).
Marking:
VFI models: Grundfos and model type (VFI) on adhesive label on sensor. Grundfos on flow pipe. All other models: Grundfos on top of sensor housing. Model type (ITS/LPS/RPS/MFS/VFS) on adhesive label on sensor.
Installation Requirements:
R001
Model:
CPS, ITS, LPS or RPS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF CPS, ITS, LPS or RPS with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII CPS model added February 2024. Product: [A] Must be CPS, ITS, LPS or RPS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E or I, second and third character have no importance for drinking water* Materials: [G] Must be either -B, -S, -I or -- Connection: [H] Must be either 03A, 03B, 03N, 02P, 01K, 16P, 66P or --- Packaging: [I] Of no importance for drinking water* ------ DPS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF DPS with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be DPS Range and unit: [B] Of no importance for drinking water* Gen.: [C] All characters allowed except 4 and 5 Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E, the second must not be A. The third character has no importance for drinking water* character have no importance for drinking water* Materials: [G] Must be either -B, -S, S-, SS or -- Connection: [H] Must be either 06C, 06T, 08T, 01L, 24N, 63B, 64S or --- Packaging: [I] Of no importance for drinking water* ------ MFS or VFS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF MFS or VFS with or without composite flow pipe accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be MFS or VFS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be A or E, second and third character have no importance for drinking water* Materials: [G] Must be either C-, CB, CS or -- Connection: [H] Must be either 03P, 03S, 04B, 04N, 04P, 04S, 05B, 05N, 05P, 05S, 07B, 07N, 07P, 09P, 01K, 15K, 18K, 22S, 26R, 28S or --- Note: 04N, 05N and 07N only in combination with CS [G] Packaging: [I] Of no importance for drinking water* ------ MFS or VFS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF MFS or VFS with or without stainless steel flow pipe accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be MFS or VFS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be A or E, second and third character have no importance for drinking water* Materials: [G] Must be either QB, QS, Q- or -- Connection: [H] Must be either 03B, 04B, 04M, 04N, 04P, 04S, 05B, 05M, 05N, 05P, 05S, 07M, 07P, 01K, 01L, 102, 22S, 28S, 51G or --- Packaging: [I] Of no importance for drinking water* ------ VFI sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF VFI with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be VFI Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E, second and third character have no importance for drinking water* Materials: [G] Must be either S-, SG, SS or -- Connection: [H] Must be either --F, --P, 05B, 05N, 07B, 07N, 07P, 09P, 30F, 31F, 32F, 33F, 35F, 37F or 42F Packaging: [I] Of no importance for drinking water* ------ Where: Code for sealing [F]: 1st character: “A” means EPDM O-rings and EPDM sealing sleeve. “E” means EPDM O-rings. “I” means EPDM O-rings and EPDM anti-sedimentation sealing cap Code for material [G]: 1st character: “C” means composite flow pipe. “Q” means flow insert and (except service sets) also a stainless steel flow pipe. “S” means stainless steel adapter (for DPS) or flow pipe. “-“ means no adapter (for DPS) or flow pipe. 2nd character: "B" means brass (fitting). “G” means cast iron (flange). “I” means composite (fitting). "S" - means stainless steel (fitting or flange). “-“ means no further accessories included. Code for connection (H): 1st two characters: “01” means 10 mm. “02” means ¼”. “03” means ½”. “04” means ¾”. “05” means 1”. “06” means 6 mm. “07” means 1¼”. “08” means 8 mm. “09” means 1½”. (Internal note - this is on a flow pipe connection) “15” means 15 mm. “16” means ⅜”. “18” means 18 mm. “22” means 22 mm. “24” means ⅛”. “26” means 42 mm. “28” means 28 mm. “30” means DIN PN25/40 DN18/25/32, ANSI B16.5 Class 300 - 1¼". “31” means DIN PN16/25/40 DN40, ANSI B16.5 Class 300 - 2". “32” means DIN PN16/25/40 DN50, ANSI B16.5 Class 300 - 2". “33” means ISO/DIN PN25/40 DN65. “35” means ISO/DIN PN25/40 DN80. “37” means ISO/DIN PN16 DN100. “42” means ISO/DIN PN25/40 DN100. “51” means 1" / ¾". “63” means ½" and ventilation opening. “64” means 15.5 mm and ventilation opening. “66” means ½” and M8 ventilation port “--” means no accessories included and thus implicitly the dimension of the sensor connection, which for DPS, ITS, LPS, MFS, RPS and VFS is 10 mm (of no importance for drinking water). For VFI this is used for service sets, which includes the sensor and the bluff body, but not the flow pipe (of no importance for drinking water). 3rd character: “A” means BSPT (short). “B” means BSPT. “C” means Compression. “F” means flange. “K” means standard clip included (of no importance for drinking water). “L” means special clip included (of no importance for drinking water). “M” means NPSM. “N” means NPT. “P” means BSPP. “R” means union not (union nut included but no fittings included). “S” means sweat. “T” means hose connector. “2” means both standard clip and special clip included (of no importance for drinking water). “-“means no accessories included and thus implicitly the connection type of the sensor, which for DPS, ITS, LPS, MFS, RPS and VFS is a clip (of no importance for drinking water). Further details on the nomenclature: * All characters are allowed NOTE - For customer-specific numbers, GG/HHH/IIII in the saleable code is replaced by the customer name. However, the customer-specific products are still covered if they meet the requirements specified in the standard sales code.
Factor:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Phone
+45 24610542

View All Listings by this Company

Print This Approval


#2306903

CMBE range of horizontal multistage centrifugal booster pumps with stainless steel bodies and impellers and EPDM ‘O’-rings. All models include an expansion vessel, non-return valve, pressure gauge and sensor on the outlet. Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2306903
Expiry date:
30/06/2028
Size:
CMBE1 & CMBE3: 1” BSPT (F) Inlet/Outlet. CMBE5: 1 ¼” BSPT (F) Inlet/1” BSPT (F) Outlet. CMBE10: 1 ½” BSPT (F) Inlet/Outlet.
Marking:
Grundfos and Grundfos logo, type, Model, P/N no. and technical info on adhesive label on end of motor housing.
Installation Requirements:
R001 R040
Model:
CMBE-XX1-XX2-I-U-C-X3-D-X4 Where: CMBE = Booster type - booster with integrated frequency inverter. XX1 = Rated flow rate [m³/h] @ 50Hz - 1, 3, 5 or 10. XX2 = Maximum head [m] - 44, 54, 62 or 93 (CMBE 1 = 44, CMBE 3 = 62 or 93, CMBE 5 = 62, CMBE 10 = 54). I = Materials in contact with liquid - Sleeve, Pump shaft, Impellers/chamber, 5-way valve: EN1.4301/AISI 304, Pressure manager: PP 30GF, Pressure tank: EPDM/steel/PP/Butyl. U = Supply Voltage [V] - 1 x 200-240 V, 50/60 Hz. C = Motor - High-efficiency motor with frequency converter (IP55). X3 = Main cable and plug options - A/B/C/D/E/H/G/J/O. D = Controller - Integrated frequency converter. X4 = Thread - A: Rp 1, B: Rp 1 1/4 or C: Rp 1 1/2.
Factor:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Phone
+45 24610542

View All Listings by this Company

Print This Approval


#2306904

‘AQ tap’ water dispensing unit incorporating a brass solenoid and a flow sensor. The unit is operated using a smart card and credit system that allows the user to obtain a set amount of water. Maximum working pressure 3.0 bar. Cold water use only.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2306904
Expiry date:
30/06/2028
Size:
½” BSP (M) inlet/outlet.
Marking:
Grundfos and Grundfos logo on front panel. Grundfos logo, type, model, Product no. and technical information on data plate on left hand side of cabinet.
Installation Requirements:
R001 R040
Model:
AQT-AA-ST-1.
Factor:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Phone
+45 24610542

View All Listings by this Company

Print This Approval


#2309919

‘SCALA1’ range of booster pumps with plastic bodies, plastic impellers, EPDM and NBR ‘O’-rings. The product incorporates a non-return valve. Maximum working pressure 8.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2309919
Expiry date:
30/09/2028
Note:
Cold water use only.
Size:
1” BSP (M) inlet/outlet.
Marking:
Grundfos and Grundfos logo on body. Grundfos and Grundfos logo, model no., and other technical information on adhesive label on body.
Installation Requirements:
R001 R415
Model:
SCALA1 3-25. SCALA1 3-35. SCALA1 3-45. SCALA1 5-25. SCALA1 5-35. SCALA1 5-55. Where 3 or 5 = flow rate in m³/h, 25-55 = max. head (m).
Factor:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Phone
+45 24610542

View All Listings by this Company

Print This Approval


#2101081

Range of pressure transmitters with stainless steel bodies. Maximum working pressures: Press.Tr.ISP40 model 25.0 bar, all other models 50.0 bar. Maximum operating temperature 90°C.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2101081
Expiry date:
31/01/2026
Size:
Press.Tr.ISP40: ½” BSP (M). Press.Tr.ISP44 NPT: ¼” NPT (M). Press.Tr.ISP44 BSP (M) ½” BSP (M).
Marking:
Grundfos, model number, CE and operating pressure range on body.
Installation Requirements:
R001
Model:
Press.Tr.ISP40 Press.Tr.ISP44
Factor:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Phone
+45 24610542

View All Listings by this Company

Print This Approval


#2310916

Range of multistage centrifugal pumps, with stainless steel bodies (CRN models) or black coloured cataphoretic electrodeposition coated cast iron bodies (CR models), stainless steel sleeve and impellers. The products can be supplied with or without a sensor. Maximum working pressures (no. of stages in brackets): CR/CRN 95 (1-5): 16.0 bar. CR/CRN 95 (6-8): 25.0 bar. CRN 95 (9-12): 40.0 bar. CR/CRN 125 (1-4): 16.0 bar. CR 125 (5): 25.0 bar. CRN 125 (6-7): 25.0 bar. CRN 125 (8-12): 40.0 bar. CR 155 (1-4): 16.0 bar. CRN 155 (1-4): 16.0 bar. CRN 155 (5-6): 25.0 bar. CRN 155 (7-11): 40.0 bar. CR/CRN 185 (1-3): 16.0 bar. CR/CRN 185 (4-5): 25.0 bar. CR/CRN 185 (6-8): 40.0 bar. CR/CRN 215 (1-3): 16.0 bar. CR/CRN 215 (4-5): 25.0 bar. CR/CRN 215 (6-7): 40.0 bar. CR/CRN 255 (1-3): 16.0 bar. CR/CRN 255 (3-4): 25.0 bar. CR/CRN 255 (5-6): 40.0 bar. When a sensor is incorporated the maximum working pressure is as follows: 25.0 bar with either the IPS44 or VTU sensor, (unless they are used on a pump with a maximum working pressure of 16.0 bar, in this instance the lesser pressure applies). The MBS3000 sensor can be used on all models, the pump maximum working pressure applies. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2310916
Expiry date:
31/10/2028
Size:
CR/CRN(E) 95 models: DN100 inlets/outlets, CR/CRN(E) 125 & CR/CRN(E) 155 models: DN150 inlets/outlets, CR/CRN(E) 185, CR/CRN(E) 215 & CR/CRN(E) 255 models: DN200 inlets/outlets. CRN(E) 95 models: PJE 4” inlets/outlets, CRN(E) 125 & CRN(E) 155 models: PJE 6” inlets/outlets, CRN(E) 185, CRN(E) 215 & CRN(E) 255 models: PJE 8” inlets/outlets.
Marking:
Grundfos logo, type, model, Prod/Ver no., technical info and manufacturing/assembly country on data plate on motor stool.
Installation Requirements:
R001 R415
Model:
Model key code: CR/CRN (E) AA-B-C-D-E-F-G-XXXX Where: CR = Pump type and Cast Iron. CRN = Pump type and EN 1.4401. E = Preminum Electronically Controlled Motor (CR /CRN 95 -125 models only). AA: Flow rate [m³/h] - 95 / 125 / 155 / 185 / 215 / 255. B: Number of impellers – dependent on model (1-12). C: Number of reduced diameter impellers - 0 / 1 / 2 / 3 / 4. D: Code for pump version: A = Basic version, B = Oversize motor, E = Pump with certificate, G = E-pump without operating panel, H = Horizontal version, I = Different pressure rating, J = E-pump with a different maximum speed, L = Pump including Grundfos CUE and certificate, N = With sensor, O = Clean and dryed, P = Undersize motor, R = Belt driven pump, T = Trust handling device, V = Cascade function, X = Special version*, Z = Pump with bearing flange. E: Code for pipe connection: F = DIN flange, G = ANSI flange, J = JIS flange, N = Changed diameter of ports, P = PJE coupling (CRN models only). F: Code for materials: A = Basic version, C = Carbon-free pump, H = Flanges and base plate EN 1.4408, L = Motor stool, base plate and flanges EN 1.4408, N = Flanges EN 1.4408, P = PEEK neck ring, Q = Silicon carbide/silicon carbide bearing in pump and silicon carbide/silicon carbide seal faces in thrust handling device, R = Silicone carbide /silicone carbide bearing, T = Baseplate EN 1.4408, U = Silicon carbide/silicon carbide bearing in pump and silicon carbide/tungsten carbide seal faces in thrust handling device, W = Tungsten carbide/tungsten carbide, X = Special*. G: Code for rubber parts: E = EPDM, V = FKM. XXXX: Code for shaft seal: HQQx, HUUx, HUBx, HQBx. Where: H = Balanced cartridge seal with O-ring B = Carbon, synthetic resin-impregnated U = Cemented tungsten carbide Q = Silicon carbide x can = E or V for rubber parts: E = EPDM, V = FKM. *Special version ONLY covers the situation where more than 4 options are selected within the same position.
Factor:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Phone
+45 24610542

View All Listings by this Company

Print This Approval


#2312902

‘SCALA1 TWIN’ range of booster pump sets, comprising of two pumps with plastic bodies, plastic impellers, EPDM and NBR ‘O’-rings and an accessory set consisting of a base plate, plastic manifold and four brass spherical valves. Each pump incorporates a non-return valve. Maximum working pressure 8.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2312902
Expiry date:
31/12/2028
Note:
R415 only apllies to the complete booster pump sets.
Size:
1¼” BSP (F) manifold inlet/outlet.
Marking:
Pumps: Grundfos and Grundfos logo on body. Grundfos and Grundfos logo, model no., and other technical information on adhesive label on body. SCALA1 Twin accessory set: Grundfos logo, Grundfos, SCALA1 and SCALA2 on base plate. .
Installation Requirements:
R001 R415
Model:
SCALA1 TWIN 3-25, SCALA1 TWIN 3-35, SCALA1 TWIN 3-45, SCALA1 TWIN 5-25, SCALA1 TWIN 5-35, SCALA1 TWIN 5-55. Where 3 or 5 = flow rate in m³/h and 25-55 = max. head (m) on the individual pumps. The models are supplied with either of the following accessory sets: SCALA1 Twin accessory set (99725165), SCALA2 Twin accessory set (99743076).
Factor:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Phone
+45 24610542

View All Listings by this Company

Print This Approval


#2312904

Range of integrated water circuits with plastic bodies and EPDM ‘O’ rings and gaskets. The assemblies incorporate flow switches, plate heat exchangers and plastic flow regulators. The primary circuit incorporates a 3.0 bar rated pressure relief valve. Maximum working pressures: 2.5 bar primary circuit, 10.0 bar secondary circuit. Maximum operating temperature 85°C.

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
2312904
Expiry date:
31/12/2028
Size:
Secondary circuit: ½” BSP (M) inlet x F4 outlet. Primary circuit: ¾” BSP (M) inlet and outlet connections.
Marking:
Grundfos and Grundfos logo on primary circuit pump.
Installation Requirements:
R001 R008
Model:
IWC ICHS UPS/UPM2/3/4-xx v.xxx-xxx Where: UPS, UPM2, UPM3, UPM4 = pump type (primary circuit). -xx = pump max. head (UPS: 50, 60, 70. UPM2: 60, 70. UPM3: 20, 40, 45, 50, 60, 70, 75. UPM4: 20, 30, 40, 45, 50, 55, 60, 65, 70, 75). v.xxx-xxx = version number-free text, and can be any alphanumerical characters.
Factor:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Phone
+45 24610542

View All Listings by this Company

Print This Approval


#240207701

‘SCALA 2’ integrated, self-priming, plastic bodied (compact) mains pressure boosting pump. Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240207701
Expiry date:
28/02/2029
Size:
1” BSPT (M) inlet and outlet.
Marking:
Grundfos and Grundfos logo on body. Grundfos and Grundfos logo, type, Model, P/N no., Serial no., P/C no., technical info, manufacturing country and data matrix on adhesive label on end of motor housing.
Installation Requirements:
R001 R415
Model:
Scala2 Model2 3-45 AKCCDE, Scala2 Model2 3-45 AKCDDE, Scala2 Model2 3-45 AKCGDE.
Factor:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Phone
+45 24610542

View All Listings by this Company

Print This Approval


#240507701

`UPM3` range of single stage circulator pumps, with stainless steel or plastic bodies, plastic impellers, ceramic shafts and bearings, EPDM 'O'-rings and seals. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240507701
Expiry date:
31/05/2029
Size:
Stainless steel body models (N): 1½” BSP (M) & 2” BSP (M). Composite (plastic) body models (CIL3): 1” BSP (M).
Marking:
Grundfos logo, Grundfos and model on top of pump housing. Production number, serial number, and technical information on side of pump housing. Stainless steel models also have a flow arrow on the body.
Installation Requirements:
R001
Model:
UPM3 **1-**2 N ***3 (GFNxx-). UPM3 **1-**2 - CIL3 ***3 (GFNxx-). Where: UPM3 = pump type and can also be: UPM3 HYBRID, UMP3 DHW, UPM3 K, UPM3 AUTO L UPM3 FLEX AS. **1 = size of inlet/outlet connection: N models – 25 = 1 ½”, 32 = 2”. CIL3 models – 15 = 1”. **2 = maximum head (dm): 20, 40, 50, 60, 70, 75 (all models). 105, 145 (stainless steel body models only). N = stainless steel body. CIL3 = composite (plastic) body. ***3 = port to port length in mm: 130 (all models) or 180 (2” models only).
Factor:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7, DK-8850 Bjerringbro
Phone
+45 24610542

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 3 of 3

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.