Delabie SAS Approvals


#2109034

Range of single hole, single outlet (fixed) combination tap assemblies incorporating chromium plated brass bodies, ceramic cartridge headwork with single lever operating member. The spout outlets incorporate either a plastic aerator or flow straightener. The 2565T1EP, 2565T3EP & 3565T5EP models are supplied with a check valve cartridge and filter on the inlets, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The 2565T1, 2565T3 & 2565T5 models have flow restrictors on the inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2109034
Expiry date:
30/09/2026
Marking:
Delabie on operating member.
Installation Requirements:
R001 R006 R009 R010
Model:
2565T1, 2565T3 & 2565T5. 2565T1EP, 2565T3EP & 2565T5EP.
Factor:
Delabie Ltd.
Company Name
Delabie Ltd.
Address
1-3 Henderson House Hithercroft Road Wallingford Oxfordshire
Postcode
OX10 9DG
Phone
+44 1491 824 449

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin

View All Listings by this Company

Print This Approval


#2110035

Chrome plated brass quick connector with EPDM washer. Maximum operating temperature 60°C.

Section:
1535 Miscellaneous
Section Subtitle:
Tap accessories.
WRAS Approval Number:
2110035
Expiry date:
31/10/2026
Note:
Open outlet use only.
Size:
See model
Marking:
AQUATOOLS on body
Installation Requirements:
R001 R040
Model:
AT820120: ½” BSP (F) x 11mm quick connector. AT820122: 22mm (F) x 11mm quick connector. AT820123: ½" BSP (M) x 11mm quick connector. AT820124: M24x1 x 11mm quick connector. AT820125: M24x1.25 x 11mm quick connector. AT820126: M16.5x1 x 11mm quick connector.
Factor:
Aqua-tools
Company Name
Aqua-tools
Address
26 rue Charles Edouard Jeanneret 78300 Poissy France
Phone
+33139750220
General Email
contacts@aqua-tools.com

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin
General Email

View All Listings by this Company

Print This Approval


#2203702

Range of thermostatic blending valves with brass bodies, EPDM ‘O’-rings and chromium plated dome type operating members. The inlets incorporate plastic strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
2010 Valves
Section Subtitle:
Blending, thermostatic.
WRAS Approval Number:
2203702
Expiry date:
31/03/2027
Size:
¾” BSP (M) inlet and outlet.
Marking:
Delabie on operating member
Installation Requirements:
R001 R010 R040
Model:
SECURITHERM 792770 & SECURITHERM 792770T
Factor:
Delabie Ltd.
Company Name
Delabie Ltd.
Address
1-3 Henderson House Hithercroft Road Wallingford Oxfordshire
Postcode
OX10 9DG
Phone
+44 1491 824 449

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin

View All Listings by this Company

Print This Approval


#2112033

Range of WC pressure flushing valves with a solenoid valve controlling the flow. The valves are operated via an infra-red sensor or push-button assembly. The solenoid valve also incorporates a lever operated isolation valve. Maximum working pressure – 5.0 Bar. Cold water use only

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2112033
Expiry date:
31/12/2026
Size:
¾” BSP (M)
Marking:
Delable on Faceplate
Installation Requirements:
R001 R120 R090 R410 R570
Model:
464000, Tempomatic WC recessed bicontrol plate 464006, Tempomatic WC recessed bicontrol plate 464PBOX, Tempomatic WC recessed 464SBOX, Tempomatic WC recessed
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin

View All Listings by this Company

Print This Approval


#2204046

Range of brass (chrome plated) quick fit connectors. Maximum operating temperature 60°C

Section:
1535 Miscellaneous
Section Subtitle:
Tap accessories.
WRAS Approval Number:
2204046
Expiry date:
30/04/2027
Note:
Open outlet use only
Size:
See models
Marking:
Delabie on body.
Installation Requirements:
R001
Model:
820122N: M22 (F) 820123: ½” BSP (M) 820124N: M24 (M) 820125: M24 (M) 820126N: M16 (M) 821122: M22 (F) 821123: ½” BSP (M) 821124: M24 (M) 821125: M24 (M)
Factor:
Delabie Ltd.
Company Name
Delabie Ltd.
Address
1-3 Henderson House Hithercroft Road Wallingford Oxfordshire
Postcode
OX10 9DG
Phone
+44 1491 824 449

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 6 of 9

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.