#2210052

Range of indirect unvented indoor heat pump storage cylinders which consist of a heat pump which sits on top of the tank and heats the hot water via refrigeration pipes which then heats the cylinder by being externally mounted around the cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressure 6.0 Bar (Secondary) Maximum operating temperature 55.0°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2210052
Expiry date:
31/10/2027
Size:
¾” BSP (F)
Marking:
KERS logo, model name, capacity, max pressure, max temp and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Model:
KERS OA - W230 KERS MVHR - W230 KERS MVHR - W200 SL KERS OA -W200 SL KERS MVHR - W160 KERS OA - W160
Factor:
KERS INNOVATION UK LTD
Company Name
KERS INNOVATION UK LTD
Address
Unit 3 ALBERT STREET, HOLLINWOOD, OLDHAM, OL8 3QPCompany

View All Listings by this Company

Print This Approval


#2211041

Range of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The secondary circuit consists of a temperature and pressure relief valve set at 10.0 bar and 90°C and an alternative temperature and pressure relief valve also set at 10.0 bar and 90°C , an inlet control group consisting of a pressure reducing valve pre-set at 3.0 bar, an expansion relief valve set at 8.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum working pressure - Primary circuit: 6.0 bar & Secondary circuit: 7.5 bar Maximum operating temperature 85.0°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2211041
Expiry date:
30/11/2027
Size:
22mm Compression on all circuits
Marking:
EVOCyle logo, max pressure, max temp, capacity and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Model:
TTAMVD-0150LFB ThermaQ Evocyl Air 150 Direct TTAMVD-0180LFC ThermaQ Evocyl Air 180 Direct TTAMVD-0210LFC ThermaQ Evocyl Air 210 Direct TTAMVD-0250LFC ThermaQ Evocyl Air 250 Direct TTAMVD-0300LFC ThermaQ Evocyl Air 300 Direct TTAMVI-0150LFB ThermaQ Evocyl Air 150 Indirect TTAMVI-0180LFC ThermaQ Evocyl Air 180 Indirect TTAMVI-0210LFC ThermaQ Evocyl Air 210 Indirect TTAMVI-0250LFC ThermaQ Evocyl Air 250 Indirect TTAMVI-0300LFC ThermaQ Evocyl Air 300 Indirect
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#2210057

Range of stainless steel indirect (single or twin coil), direct and heat pump unvented hot water storage cylinders. The heat pump models also incorporate a plate heat exchanger and a circulation pump. The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@90.0˚C. The products are supplied with an inlet control group consisting of an adjustable pressure reducing valve, adjustable in the range of 0.8 bar - 6.0 bar, but factory pre-set at 3.0 bar, a strainer, am expansion relief valve set at 6.0 bar and an approved single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The products are also supplied with an immersion heater, an expansion vessel (12, 19 or 24 litres depending on model) and a tundish. Maximum supply pressure to the inlet control group: 16.0 bar. Maximum working pressure: Secondary circuit: 5.5 Bar. Primary Circuit: 6.0 Bar (All models except for the Direct - DI prefix models). Maximum operating temperature 75°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2210057
Expiry date:
31/10/2027
Note:
R008 only applies to the HP prefix (Heat Pump) models. Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression or 28mm stub (Heat Pump models only).
Marking:
WARMFLOW logo, capacity, model name, maximum pressure, maximum temperature, date of manufacture (month/YYYY) and other technical info on adhesive label on body.
Installation Requirements:
R001 R008 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°C and 45°C.
Model:
DI110UV - Direct Unvented water cylinder, DI140UV - Direct Unvented water cylinder, DI170UV - Direct Unvented water cylinder, DI200UV - Direct Unvented water cylinder, DI240UV - Direct Unvented water cylinder, DI290UV - Direct Unvented water cylinder. IN110UV - Indirect Unvented water cylinder, IN140UV - Indirect Unvented water cylinder, IN170UV - Indirect Unvented water cylinder, IN200UV - Indirect Unvented water cylinder, IN240UV - Indirect Unvented water cylinder, IN290UV - Indirect Unvented water cylinder. C140UV - Indirect Unvented water cylinder, C170UV - Indirect Unvented water cylinder, C200UV - Indirect Unvented water cylinder. TW170UV - Twin coil indirect Unvented water cylinder, TW200UV - Twin coil indirect Unvented water cylinder, TW240UV - Twin coil indirect Unvented water cylinder, TW290UV - Twin coil indirect Unvented water cylinder. HP170UV - Heat pump indirect unvented water cylinder, HP200UV - Heat pump indirect unvented water cylinder, HP240UV - Heat pump indirect unvented water cylinder, HP290UV - Heat pump indirect unvented water cylinder.
Manufacturer:
Warmflow Engineering Co. Ltd
Company Name
Warmflow Engineering Co. Ltd
Address
Lissue Industrial Estate, Moira Road, Lisburn Northern Ireland
Phone
02892 62 1515

View All Listings by this Company

Print This Approval


#2301036

Range of stainless steel indirect unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 90°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit: 5.5 Bar Primary circuit: 3.0 Bar Solar circuit: 3.0 Bar

Non-metallic materials and components comply with BS6920 at 80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2301036
Expiry date:
31/01/2028
Size:
Secondary circuit: 22mm compression. Primary circuit: 28mm compression. Solar circuit: 22mm compression
Marking:
World Heat, model no., serial no., capacity, Max working pressure, expansion vessel pressure, all on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Model:
120ECOSLIMSS 150ECOSLIMSS 180ECOSLIMSS 210ECOSLIMSS 120ECOSLIMSOLSS 150ECOSLIMSOLSS 180ECOSLIMSOLSS 210ECOSLIMSOLSS 120TCSSFLOWSLIM 150TCSSFLOWSLIM 180TCSSFLOWSLIM 210TCSSFLOWSLIM 120DSSFLOWSLIM 150DSSFLOWSLIM 180DSSFLOWSLIM 210DSSFLOWSLIM 120ISSFLOWSLIM 150ISSFLOWSLIM 180ISSFLOWSLIM 210ISSFLOWSLIM
Manufacturer:
World heat Ltd
Company Name
World heat Ltd

View All Listings by this Company

Print This Approval


#2303040

Range of indirect unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 6.0 bar Secondary: 5.5 bar

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2303040
Expiry date:
31/03/2028
Size:
Primary: 22mm Compression Secondary: 22mm compression
Marking:
Joule, Model name, capacity, max pressures, max temps and other technical information on label on body
Installation Requirements:
R001 R140 R360
Model:
TUMA-00150-LFC TUMA-00180-LFC TUMA-00210-LFC
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 10 of 11

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.