#240402715

Pump with a plastic body and impeller. Maximum working pressure 0.3 bar. Maximum operating temperature 98°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240402715
Expiry date:
30/04/2029
Size:
9.4mm OD spigot inlet x 13.98mm OD spigot outlet
Marking:
Hyco Manufacturing Ltd and product info on label.
Installation Requirements:
R001 R008
Model:
ZEN-PO1 - HYCO PUMP
Factor:
Hyco Manufacturing Ltd.
Company Name
Hyco Manufacturing Ltd.
Address
Unit 1 & 2 Normandy Court, Express Way, West Yorkshire
Postcode
WF10 5NR
Phone
01924 225 200

View All Listings by this Company

Print This Approval


#240404711

Peripheral pump for mains water applications with a brass body and impeller, . The pushfit connections on the hoses are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240404711
Expiry date:
30/04/2029
Size:
Pump body: ¾” BSP (M). Inlet and outlet hoses: 15mm pushfit.
Marking:
Mains boost, manufacturer’s address, www.stuart-turner.co.uk and other technical information printed on body. Two adhesive labels on body, one with serial no., the other includes the part no. and other technical information.
Installation Requirements:
R001 R007 R009
Model:
47708 STORMBOOST, 44995 STORMBOOST.
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2303077

Range of submersible pumps with stainless steel bodies and impellers and NBR gaskets and ‘O’-rings. Maximum working pressure 15.0 bar (VL and CL series pumps only).

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2303077
Expiry date:
31/03/2028
Note:
The level control assembly (cable and level control) are not covered under the scope of this approval. These pumps are also open outlet use only.
Size:
1 ¼” Female BSP outlet.
Marking:
Salamander Pumps, pressure and date of manufacture (DD/MM/YYY) on adhesive label on body.
Installation Requirements:
R001 R415
Model:
MSUBPU01 SUBMERSIBLE MULTISTAGE PUMPS
Factor:
Salamander Pumps Ltd
Company Name
Salamander Pumps Ltd
Postcode
SR5 3XE
Phone
0191 516 2002

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 4

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.