Heaters

Section Code 1465 : Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.

Back To Directory Sections

#2110320

Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2110320
Expiry date:
31/10/2026
Size:
22mm compression
Marking:
Worcester (brand of Bosch) on front of boiler. Worcester, address, model, serial No. & other tech info on adhesive label on inside of panel.
Installation Requirements:
R001
Model:
Greenstar Highflow range comprising of model numbers: 7 731 600 098 (model code: 440CDi ErP). 7 731 600 099 (440CDi ErP). 7 731 600 100 (550CDi ErP). 7 731 600 101 (550CDi ERP).
Manufacturer:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company

Print This Approval


#2111371

Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111371
Expiry date:
30/11/2026
Size:
2 ½” BSP (M)
Marking:
Lochinvar on front casing. Lochinvar , model & serial number on adhesive label on body
Installation Requirements:
R001 R140 R360
Model:
TTW410 & TTW580 FLOOR STANDING GAS FIRED COMBINATION BOILERS
Factor:
Lochinvar Ltd.
Company Name
Lochinvar Ltd.
Address
7 Lombard Way The MXL Centre Banbury
Postcode
OX16 4TJ
Country
Oxon
Phone
+44 (0) 1295 269981
General Email
general@lochinvar.ltd.uk

View All Listings by this Company

Print This Approval


#2112354

Range of gas fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The cold inlet incorporates an angled spherical valve with a brass body, chromium plated brass ball and a lever operating member. The primary circuit incorporates an expansion vessel, isolation valves on flow and return, drain valve and a pressure relief valve set at 3.0 bar. Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature for the secondary circuit is 55˚C. Cold supply only.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2112354
Expiry date:
31/12/2026
Size:
Secondary: 15mm copper tail. Primary: 22mm copper tail.
Marking:
Biasi and Biasi logo on front panel. Biasi, Biasi logo, pressure, model and other technical information on label on inside cover.
Installation Requirements:
R001 R140 R360
Model:
Advance Plus 25C ERP, Advance Plus 30C ERP, Advance Plus 35C ERP, M300V.2025 SM, M300V.2530 SM, M300V.3035 SM, M275V.2024 SM, M275V.2428 SM, M275V.2832 SM.
Factor:
BSG Caldaie a gas S.p.A.
Company Name
BSG Caldaie a gas S.p.A.
Address
Via Pravolton, 1 - 33170, Pordenone (PN)
Country
Italy
Phone
+39 0434 238311

View All Listings by this Company

Print This Approval


#2111364

Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111364
Expiry date:
30/11/2026
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. R430 applies to the EXT models only.
Size:
Primary: 28mm copper tail (25/32 models), 22mm copper tail (all other models). Secondary: 15mm inlet x 22mm copper tail outlet.
Marking:
Worcester (brand of Bosch Thermotechnology Ltd) and Worcester logo on front casing. Data label, Worcester and technical information on inside cover.
Installation Requirements:
R001 R140 R360 R430
Model:
7 731 600 165 Greenstar Heatslave II 12/18 ErP+, 7 731 600 166 Greenstar Heatslave II 18/25 ErP+, 7 731 600 167 Greenstar Heatslave II 25/32 ErP+, 7 731 600 168 Greenstar Heatslave II EXT 12/18 ErP+, 7 731 600 169 Greenstar Heatslave II EXT 18/25 ErP+, 7 731 600 170 Greenstar Heatslave II EXT 25/32 ErP+, 7 731 600 260 Greenstar Heatslave II 12/18 2022+, 7 731 600 261 Greenstar Heatslave II 18/25 2022+, 7 731 600 262 Greenstar Heatslave II 25/32 2022+, 7 731 600 263 Greenstar Heatslave II EXT 12/18 2022+, 7 731 600 264 Greenstar Heatslave II EXT 18/25 2022+, 7 731 600 265 Greenstar Heatslave II EXT 25/32 2022+.
Factor:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company
Manufacturer:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Danesmoor Works Pilsley Clay Cross Chesterfield Derbyshire
Postcode
S45 9BY

View All Listings by this Company

Print This Approval


#2201303

Greenstar range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits and a pressure relief valve (set at 3.0 bar). Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 90°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2201303
Expiry date:
31/01/2027
Note:
The 7-733-601-272 prefix kit is not approved in its own right.
Size:
Models which incorporate the prefix kit: All circuits 22mm compression. 7-733-601-272 Prefix kit: All circuits 22mm compression inlets x ¾” BSP (M) outlets. Models which do not incorporate the prefix kit: All circuits ¾” captive nut.
Marking:
Worcester on front panel. Worcester, model, address, serial number and other technical information on data label on inside of case.
Installation Requirements:
R001 R140 R360
Model:
The following models incorporate the prefix kit: 7-733-600-134: Greenstar HIU KE plus with Heat Meter, 7-733-600-135: Greenstar HIU KE Plus, 7-733-600-136: Greenstar HIU E plus with Heat Meter, 7-733-600-137: Greenstar HIU E plus, 7-733-600-138: Greenstar HIU E with Heat Meter, 7-733-600-139: Greenstar HIU E, 7-733-600-140: Greenstar HIU with Heat Meter & 7-733-600-141: Greenstar HIU. The following models are sold without the prefix kit: 7-735-600-662: Greenstar HIU KE plus with Heat Meter, 7-735-600-661: Greenstar HIU KE Plus, 7-735-600-660: Greenstar HIU E with Heat Meter, 7-735-600-659: Greenstar HIU E, 7-735-600-663: Greenstar HIU with Heat Meter, 7-735-600-658: Greenstar HIU. Prefix kit (which must be installed in conjunction with the aforementioned models): 7-733-601-272. Models added May 2023 (incorporate prefix kit 7-733-601-272): 7-735-600-724: Greenstar HIU E with Heat Meter, 7-735-600-725: Greenstar HIU KE with Heat Meter, 7-735-600-726: Greenstar HIU with Heat Meter.
Manufacturer:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 5 of 8

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.