Heaters

Section Code 1465 : Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.

Back To Directory Sections

#2207375

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207375
Expiry date:
31/07/2027
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
I-MINI² printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
I-MINI²C24 I-MINI²C30 I-MINI²C35
Factor:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Kingston Upon Hull
Postcode
HU5 4JN
Country
East Yorkshire
Phone
0870 8498056
General Email
enquiries@idealheating.com

View All Listings by this Company

Print This Approval


#2207373

Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2207373
Expiry date:
31/07/2027
Size:
Secondary: 15mm compression. Primary: 22mm compression.
Marking:
KESTON printed on front casing. Model and size printed on drop down door.
Installation Requirements:
R001 R140 R360
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
KESTON COMBI² C30 & KESTON COMBI² C35 COMBINATION BOILERS
Factor:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Kingston Upon Hull
Postcode
HU5 4JN
Country
East Yorkshire
Phone
0870 8498056
General Email
enquiries@idealheating.com

View All Listings by this Company

Print This Approval


#2306060

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2306060
Expiry date:
30/06/2028
Size:
DHW: 15mm compression CH: 22mm compression
Marking:
Vailant on front cover. Vailant, Model,Pressure, Temperature and other information on adhesive label on rear of body
Installation Requirements:
R001 R140 R360
Model:
VUW 20/26CS/1-5 (N-GB) ecoTEC plus 826 VUW 25/32CS/1-5 (N-GB) ecoTEC plus 832 VUW 30/36CS/1-5 (N-GB) ecoTEC plus 836 VUW 30/40CS/1-5 (N-GB) ecoTEC plus 840 VUI 30/40CS/1-5 (N-GB) ecoTEC plus 940
Factor:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company
Manufacturer:
Vaillant Industrial UK Ltd
Company Name
Vaillant Industrial UK Ltd
Address
Nottingham Road Belper Derbyshire
Postcode
DE56 1JT
Phone
01773 824141

View All Listings by this Company

Print This Approval


#2309044

Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system. The products can be supplied with a rigid or flexible filling loop or keyless filling link. The flexible and rigid filling loops incorporate a flexible hose or copper pipe, isolation valve, double check valve assembly (suitable for back flow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (suitable for back flow protection against fluid category 3). The products also incorporate an expansion vessel and pressure relief valve set at 3.0 bar. Maximum working pressure of primary circuit 2.5 bar. Maximum operating temperature of primary circuit 85°C Maximum working pressure of secondary circuit 8.0 bar Maximum operating temperature of secondary circuit 60°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2309044
Expiry date:
30/09/2028
Note:
When installing the keyless filling link, the discharge from the relief outlet port of this fitting must be made via a type AA, AB or AD air gap, or in accordance with EN 1717.
Size:
¾” BSP (M) (primary circuit). ½” BSP (M) (secondary circuit).
Marking:
Baxi on front cover.
Installation Requirements:
R001 R140 R360
Model:
7796586 BAXI 624 COMBI 2 7796587 BAXI 630 COMBI 2 7796588 BAXI 636 COMBI 2 7813609 BAXI 624 COMBI LPG 2 7814304 BAXI 824 COMBI 2 7814305 BAXI 830 COMBI 2 7814306 BAXI 836 COMBI 2 7814307 BAXI 830 COMBI LPG 2 7814308 BAXI 836 COMBI LPG 2 7814309 BAXI ASSURE 524 COMBI 2 7814310 BAXI ASSURE 530 COMBI 2 7814311 BAXI ASSURE 536 COMBI 2 7814312 BAXI ASSURE 530 COMBI LPG 2
Factor:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval


#2309313

‘SATK 32’ range of indirect heat interface units providing instantaneous hot water. Domestic hot water is provided via a plate heat exchanger and this circuit incorporates a flow detector, stainless-steel filter and water hammer arrestor. The primary/space heating circuit incorporates a pressure relief valve set at 2.5 bar and an expansion vessel. Maximum working pressure of the domestic hot water circuit is 10.0 bar. Maximum working pressure of the primary circuit is 16.0 bar. Maximum working pressure of the space heating circuit is 2.5 bar. Maximum operating temperature 90°C.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2309313
Expiry date:
30/09/2028
Size:
¾” BSP (M).
Marking:
Caleffi and Caleffi logo moulded on face of unit. Caleffi, Caleffi logo, model number and technical info on data plate inside unit.
Installation Requirements:
R001 R140 R360
Model:
SATK32103 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 50kW. SATK32105 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 60kW. SATK32107 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 75kW.
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
PLANT 2. S.R. 229 28010 Fontaneto d'Agogna (NO)
Country
Italy
Phone
+39 0322 8491

View All Listings by this Company

Print This Approval


#240202716

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel filter. The primary and secondary circuit incorporates isolation valves on the flow and the primary also has one on the return. Maximum working pressures: Secondary DHW: 10.0 Bar Primary CH: 2.5 Bar Maximum operating temperatures: Secondary DHW: 65.0°C Primary CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240202716
Expiry date:
28/02/2029
Size:
DHW: 22mm compression. CH: 22mm compression
Marking:
Vaillant logo, serial number, CE, pressure and other technical information on adhesive label on bottom of unit
Installation Requirements:
R001 R140 R360
Model:
0010019980 – VUW 246/7-2 (H-GB) ecoTec sustain 24 0010019981 – VUW 286/7-2 (H-GB) ecoTec sustain 28 0010019982 – VUW 346/7-2 (H-GB) ecoTec sustain 34
Factor:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 4

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.