Heaters

Section Code 1365 : Electric instantaneous, open outlet, mains fed.

Back To Directory Sections

#2204324

Under counter electric instantaneous water heater with a stainless steel tank. The flow is controlled via a solenoid valve. The product is supplied with a 3 way isolation valve (15mm compression x 15mm compression x ¾” BSP (M)), as well as a filter head and filter cartridge for installation prior to the under counter unit. LLDPE tubing and pushfit connections are provided for connecting between these items. The filter head inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet to the under counter unit incorporates a combined silicone washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.5 bar. Maximum operating temperature 98˚C. Cold water supply only.

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2204324
Expiry date:
30/04/2027
Note:
R120, R150 & R170 apply to the filter cartridge.
Size:
15mm compression (to 3 way inlet valve).
Marking:
Proboil.4E on front casing. Pressure, model, serial number and other technical information on adhesive label on rear of body.
Installation Requirements:
R001 R008 R120 R150 R170 R040
Model:
PROBOIL4E - model code: PT1030RMC.
Factor:
Norcros Group (Holdings) Limited T/A Abode
Company Name
Norcros Group (Holdings) Limited T/A Abode
Address
Unit L Zenith Park Whailey Road
Postcode
S75 1HT
Country
Barnsley
Phone
01226 283434
General Email
pillingworth@abodedesigns.co.uk

View All Listings by this Company

Print This Approval


#2207038

Range of electric instantaneous water heaters. The DEX and DCX models incorporate a spherical ball valve on the inlet. The CEX and DEX models incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet incorporates a strainer. Maximum working pressure 10 bar (DEX models only) All other models open outlet. Maximum operating temperature: ES3/4/5 and Zip Hydrotap G4/G5 ranges – 65ºC. CEX, DEX and DCX ranges - 70°C.

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2207038
Expiry date:
31/07/2027
Size:
ES, Zip HydroTap and CEX models - ½” BSP male inlet and outlet. DEX and DCX models- 3/8” BSP captive nut inlet and outlet that connects to a valve with a ½” BSP male inlet.
Marking:
Zip inline and Clage on front cover. Zip inline, model, Maximum temperature and pressure and technical information on label on body.
Installation Requirements:
R001 R040
Model:
ES3 ES4 ES6 CEX CEX-U DEX12 NEXT DCX NEXT ZIP HydroTap G4 & G5 booster
Factor:
Zip Heaters UK Ltd T/A Zip Water UK
Company Name
Zip Heaters UK Ltd T/A Zip Water UK
Address
Trafalgar House, Trafalgar Business Park, Dereham
Postcode
NR19 1JG
Phone
0345 600 5005

View All Listings by this Company
Manufacturer:
Clage GmbH
Company Name
Clage GmbH
Address
PIROLWEG 1 5 21337 LUENEBURG GERMANY

View All Listings by this Company

Print This Approval


#2210009

Electric, instantaneous, vented, mains water heaters with plastic housings and silicon gaskets. Model AQ5001353 incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum working pressure 1.5 bar.

Non-metallic materials and components comply with BS6920 at 98°C

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2210009
Expiry date:
31/10/2027
Size:
3/8" BSP male inlet x 3/8" BSP male outlet. Models added March 2023: ½” BSP male inlet x 3/8” BSP male outlet.
Marking:
Aqualogic NT on body. Pressure and model on adhesive label on rear of body.
Installation Requirements:
R001
Model:
AQ5001352 Models added Jan 2023: AQ5001353.
Factor:
Aqualogic NT Limited
Company Name
Aqualogic NT Limited
Address
20-23 Woodside Place, Glasgow
Postcode
G3 7QF
Country
United Kingdom
Phone
0141 582 1399

View All Listings by this Company

Print This Approval


#2210067

Electric, instantaneous, vented, mains water heaters with plastic housings and silicon gaskets. Incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum working pressure 1.5 bar.

Non-metallic materials and components comply with BS6920 at 98°C

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2210067
Expiry date:
31/10/2027
Size:
½” BSP male inlet x 3/8” BSP male outlet.
Marking:
PROBOIL.2X on body. Pressure and model on adhesive label on rear of body.
Installation Requirements:
R001
Model:
PROBOIL.2X
Factor:
Norcros Group (Holdings) Limited T/A Abode
Company Name
Norcros Group (Holdings) Limited T/A Abode
Address
Unit L Zenith Park Whailey Road
Postcode
S75 1HT
Country
Barnsley
Phone
01226 283434
General Email
pillingworth@abodedesigns.co.uk

View All Listings by this Company

Print This Approval


#2210068

Electric, instantaneous, vented, mains water heaters with plastic housings and silicon gaskets. Maximum working pressure 1.5 bar.

Non-metallic materials and components comply with BS6920 at 98°C

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2210068
Expiry date:
31/10/2027
Size:
3/8" BSP male inlet x 3/8" BSP male outlet.
Marking:
Reginox on body.
Installation Requirements:
R001
Model:
TRIBEZI / AMANZI TANK
Factor:
Reginox UK Ltd.
Company Name
Reginox UK Ltd.
Address
Units 1-4 Radnor Park Trading Estate, Back Lane, Congleton
Postcode
CW12 4XJ
Country
Cheshire

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 4

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.