Heat Exchangers

Section Code 1350 :

Back To Directory Sections

#2011035

Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2011035
Expiry date:
30/11/2025
Note:
There are no pipework connections on this product to facilitate the filling of the space heating circuit. The installer must provide this separately.
Size:
Domestic hot water and District heating circuits: ¾” BSP (M) inlet/outlet. Space heating circuit: ¾” BSP captive nut inlet/outlet.
Marking:
YGHP on front cover. YGHP, model number, company address and technical info on adhesive label on side of body.
Installation Requirements:
R001 R140 R360 R511
Proviso:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
YGINDRADSTD33/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 33kW / HTG 10kW. YGINDRADSTD40/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 40kW / HTG 10kW. YGINDRADSTD50/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 50kW / HTG 10kW. YGINDRADSTD60/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 60kW / HTG 10kW. YGINDRADSTD75/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 75kW / HTG 10kW. YGINDRADSTD90/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 90kW / HTG 10kW. YGINDRADSTD120/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 120kW / HTG 10kW. Models added March 2021: YGINDUFHSTD33/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 33kW / HTG 10kW YGINDUFHSTD40/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 40kW / HTG 10kW YGINDUFHSTD50/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 50kW / HTG 10kW YGINDUFHSTD60/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 60kW / HTG 10kW YGINDUFHSTD75/15.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 75kW / HTG 15kW YGINDUFHSTD90/15.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 90kW / HTG 15kW YGINDUFHSTD120/30.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 120kW / HTG 30kW
Factor:
YGHP
Company Name
YGHP

View All Listings by this Company

Print This Approval


#2101035

Range of stainless-steel heat exchangers. Maximum working pressure of primary Circuit 3.0 bar. Maximum working pressure of secondary Circuit 10.0 bar. Maximum operating temperature 80˚C

Section:
1350 Heat Exchangers
WRAS Approval Number:
2101035
Expiry date:
31/01/2026
Size:
Primary Circuit ¾” captive nut x ¾” BSP (M) Sanitary Circuit 21mm (OD) Spigot Fitting x ½” BSP (M)
Marking:
Condevo SpA, serial number and date of manufacture (DD/MM/YY) on adhesive label on body.
Installation Requirements:
R001
Model:
Type E 12439 PP11CE6V02, PP21CE6V02 & PP33CE6V02. Type E 12440 PP10CE6H02, PP22CE6H02 & PP34CE6H02.
Manufacturer:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company

Print This Approval


#2012353

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2012353
Expiry date:
31/12/2025
Size:
¾” BSP (M)
Marking:
Inta logo, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
HIPER2TPSZ80
Factor:
Intatec Ltd
Company Name
Intatec Ltd
Address
Airfield Industrial Estate, Hixon, Staffs.
Postcode
ST18 0PF
Country
United Kingdom
Phone
+44 1889 272 199

View All Listings by this Company

Print This Approval


#2010078

Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C

Section:
1350 Heat Exchangers
WRAS Approval Number:
2010078
Expiry date:
31/10/2025
Size:
¾” Male inlet and outlet
Marking:
RINNAI on body and data badge including date of manufacture (YY/MM)
Installation Requirements:
R001
Model:
REU-N3237FFC-E – N1600i (57.9kW / 29Kg) REU-N3237WC-E – N1600e (57.9kW / 29Kg) REU-N2635FFC-E – N1300i (47kW / 28Kg) REU-N2635WC-E – N1300e (47kW / 28Kg)
Manufacturer:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870

View All Listings by this Company

Print This Approval


#2012362

Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2012362
Expiry date:
31/12/2025
Size:
½” BSP (F).
Marking:
Recoup logo, pipe ID outside wall, PVC-U 63x2.0, 16028740 kiwa, 5 16-01-19 11.40, PVC MET HERGERBUIKGRANTIE on adhesive label on outside wall.
Installation Requirements:
R001 R008 R150
Model:
Recoup Pipe HEX: R-PHX-01 (2.1m length). Recoup Pipe HEX-Rd: R-PHX-03 (1.7m length).
Factor:
Recoup Energy Solutions Ltd.
Company Name
Recoup Energy Solutions Ltd.
Address
Trumpeter House Trumpeter Way Long Stratton Norfolk
Postcode
NR15 2DY
Phone
+44 (0) 1379 844 010

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 5 of 11

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.