Section Code 0550 : Two hole tap with a single outlet and a swivel spout. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
Back To Directory SectionsRange of two-hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model) incorporating a ceramic cartridge headwork with a dome type operating member. The spout outlet incorporates a plastic aerator. The headwork is connected to the spout via a stainless steel braided PEX lined flexible hose assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60.0°C
Range of two-hole, single outlet (swivel) combination tap assemblies, (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a stainless steel filter washer and plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model), incorporating quarter turn ceramic disc headworks with either cross top, dome type or single lever operating members (see model). The spout outlet, excluding the F6134 & F6144 models, incorporates a plastic aerator. The products are supplied with metal backnuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assembly with brass bodies (chrome plated), incorporating non-rising spindle headworks with dome type operating member and a quarter turn ceramic disc headwork with single lever operating member. The spout outlet incorporates a plastic aerator or plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 6.0 Bar Maximum operating temperature 65.0°C
Range of two hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model), incorporating quarter turn ceramic disc headworks with either cross top, dome type or single lever operating members (see model). The products are supplied with metal backnuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator or flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar Maximum operating temperature 65°C.
Two-hole, single outlet, swivel, combination tap assembly with (brass bodies - various finishes) incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The product is supplied with a stainless steel braided PEX lined flexible hose assembly for connection between the control valve and the spout. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of two-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes), incorporating quarter or half turn ceramic disc headworks with various operating members. The spout outlets incorporate plastic aerators. Maximum working pressure: 5.0 bar. Maximum operating temperature: 60°C
Wall mounted, two hole, single outlet (swivel) combination tap assembly incorporating a brass body (various finishes) and a ceramic cartridge headwork with joystick operating member. The spout outlet incorporates a plastic aerator. The spout outlet connections also incorporate a plastic flow regulator and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection. The spout outlet incorporates a plastic flow regulator with stainless steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet swivel combination tap assembly (chrome plated brass), incorporating non-rising spindle headworks with dome operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Page 6 of 7
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.