Combination Tap Assemblies

Section Code 0450 : Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#1905360

Range of two hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating ceramic cartridge headwork with single lever operating members. Maximum working pressure 4.0 bar. Maximum operating temperature 85°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905360
Expiry date:
31/05/2024
Size:
Stainless steel braided EPDM lined hose assembly incorporating ½” captive nut end connections.
Marking:
Kohler on operating member
Installation Requirements:
R001 R006 R010
Model:
Loure DM 14675W-4-**. ‘**’ denotes finish and can be replaced by: CP – Polished chrome SN – Vibrant polished Nickel BN – Vibrant Brushed Nickel
Factor:
Kohler UK
Company Name
Kohler UK
Address
Cromwell Road Cheltenham GL52 5EP
Phone
+44 (0)1242 283790
General Email
info@kohler.co.uk

View All Listings by this Company

Print This Approval


#1905338

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905338
Expiry date:
31/05/2024
Size:
Stainless steel braided PEX lined hose assembly incorporating ½” captive nut
Marking:
Lota on body
Installation Requirements:
R001 R006 R009 R010
Model:
60148-5101
Manufacturer:
Xiamen Lota International Co. Ltd.
Company Name
Xiamen Lota International Co. Ltd.
Address
No 61 Xingnan Road Jimei District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#1905329

Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator and some models are supplied with a pop-up waste. Maximum working pressure 10 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905329
Expiry date:
31/05/2024
Note:
No testing performed on pop-up waste
Size:
Stainless steel braided PEX lined hose assembly incorporating 3/8” captive nut end connections.
Marking:
Duravit on operating member
Installation Requirements:
R001 R006 R009 R010
Model:
B31010 0010 10, B31010 0020 10, B31020 0010 10, B31020 0020 10, B31030 0010 10 & B31030 0020 10.
Factor:
Duravit AG
Company Name
Duravit AG
Address
Werderstrasse 36 78132 Hornberg Germany

View All Listings by this Company

Print This Approval


#1905365

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator & the product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905365
Expiry date:
31/05/2024
Size:
Stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections.
Marking:
AV on body.
Installation Requirements:
R001 R006 R010
Model:
500267PEX0
Manufacturer:
Vicario Armando & C Srl
Company Name
Vicario Armando & C Srl
Address

View All Listings by this Company

Print This Approval


#1905372

‘Eurocube E’ wall mounted, electronically operated combination tap assemblies (chromium plated brass) incorporating a solenoid valve controlling the flow which is actuated via in infrared sensor. The spout outlets incorporate a plastic aerator. Model 36.264.001 is an installation set intended for use with model 36.442. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905372
Expiry date:
31/05/2024
Size:
½” BSP (M)
Marking:
Grohe on face sensor plate
Installation Requirements:
R001 R040
Model:
Grohe ‘Eurocube E’ 36.442 & 36.264.001.
Manufacturer:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg 58675 Hemer
Country
Germany
Phone
02372 930

View All Listings by this Company

Print This Approval


#1905386

Opal Prime range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905386
Expiry date:
31/05/2024
Size:
Stainless steel braided PEX lined hose assembly incorporating ½” captive nut end connections.
Marking:
Jaquar on operating member
Installation Requirements:
R001 R006 R009 R010
Model:
Opal Prime OPP-CHR-15005-BPM & OPP-CHR-15011-BPM
Factor:
Jaquar UK Ltd
Company Name
Jaquar UK Ltd
Address
Betchworth House 57-65 Station Road Redhill
Postcode
RH1 1DL
Country
Surrey
Phone
+44 844 807 2345

View All Listings by this Company
Manufacturer:
Jaquar UK Ltd
Company Name
Jaquar UK Ltd
Address
Betchworth House 57-65 Station Road Redhill
Postcode
RH1 1DL
Country
Surrey
Phone
+44 844 807 2345

View All Listings by this Company

Print This Approval


#1905027

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headworks with single lever operating member and waterfall type spout. The hose inlets incorporate a stainless-steel strainer and the product is supplied with a click type pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905027
Expiry date:
31/05/2024
Size:
Stainless steel braided PEX lined flexible hose assemblies with ½” BSP captive nuts
Marking:
Lota on rear of body
Installation Requirements:
R001 R006 R009 R160
Model:
62915-7001
Manufacturer:
Xiamen Lota International Co. Ltd.
Company Name
Xiamen Lota International Co. Ltd.
Address
No 61 Xingnan Road Jimei District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#1905055

Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headworks with single lever operating member. The spout outlets incorporate a plastic flow straightener. Model B1811AA is supplied with a lever type pop up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60 °C

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905055
Expiry date:
31/05/2024
Note:
No testing performed on pop up waste.
Size:
Stainless steel braided polyethylene lined flexible hose assemblies incorporating ⅜” captive nut end connections.
Marking:
Ideal Standard on operating member.
Installation Requirements:
R001 R006 R009 R010
Model:
B1811AA Ceraflex SL 1 hole basin mixer PUW, B1812AA Ceraflex SL 1 hole basin mixer no waste & B1959AA Ceraflex SL 1 hole bath filler
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1905056

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The product is supplied with a lever type pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905056
Expiry date:
31/05/2024
Note:
No testing performed on pop-up waste
Size:
Stainless steel braided polyethylene lined hose assemblies incorporating ⅜” captive nut end connections.
Marking:
Ideal Standard logo on top of operating member
Installation Requirements:
R001 R006 R009 R010
Model:
B1708AA Ceraflex Basin Mixer
Factor:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT

View All Listings by this Company

Print This Approval


#1905067

Range of single hole, single outlet (fixed) combination tap assembly (various finishes), incorporating quarter turn (/L or /F models) or half turn (/H models) ceramic disc headworks. The spout outlets incorporate a plastic aerator. The product can be supplied with pop-up wastes. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1905067
Expiry date:
31/05/2024
Note:
No testing performed on pop-up waste
Size:
Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections
Marking:
Lefroy Brooks logo on underside of spout
Installation Requirements:
R001 R006 R010
Model:
XX1185/H, XX1188/H, XX1189/H. XX1185L, XX1188/L, XX1189/L. XX1185/F, XX1188/F, XX1189/F. ‘XX’ denotes finish and is replaced with CP - Polished Chrome NK - Polished Nickel BC - Brushed Chrome BN - Brushed Nickel PB - Polished Brass BPB - Brushed Brass AG - Antique Gold HRG - Hard Rubbed Gold CM - Champagne Gold BCM - Brushed Champagne Gold CO - Copper
Factor:
Lefroy Brooks Midland Ltd
Company Name
Lefroy Brooks Midland Ltd
Address
Unit 3 Marston Road Ind Est Marston Road Wolverhampton
Postcode
WV2 4LX
Country
West Midlands
Phone
01902 390893

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 58

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.