Combination Tap Assemblies

Section Code 0445 : Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#2207322

Single hole, single outlet (swivel) combination tap assembly (chrome plated brass) incorporating a ceramic cartridge headwork with single lever operating member and pull out spray handset. The spout outlet incorporates a plastic aerator. Maximum working pressure 5 bar. Maximum operating temperature 65°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2207322
Expiry date:
31/07/2027
Size:
Stainless steel braided EPDM lined flexible hose assemblies with ½” BSP (F) captive nut end connections.
Marking:
Deva on front of body. DTC25 on rear of body.
Installation Requirements:
R001 R090
Model:
PEN104 – Pendle pull out kitchen mixer
Factor:
Methven UK Limited
Company Name
Methven UK Limited
Address
3-3A Stone Cross Court, Yew Tree Way, Golborne, Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602

View All Listings by this Company

Print This Approval


#2212704

Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass bodies), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet are pull-out spray type, which incorporates aerators and approved single check valve cartridges, however the complete assemblies have not been tested to demonstrate backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 65.°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2212704
Expiry date:
31/12/2027
Size:
Stainless steel braided EPDM lined flexible hoses with 1/2" BSP captive nuts 15mm compression inlet adapter on stainless Steel braided EPDM lined flexible hoses – Model M9604T
Marking:
PPI on tap body.
Installation Requirements:
R001 R090
Model:
167028 907013 M9604T
Manufacturer:
PPI Xiamen Industry Co Ltd
Company Name
PPI Xiamen Industry Co Ltd
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen 361022
Country
China

View All Listings by this Company

Print This Approval


#2210329

Single hole, single outlet (swivel) combination tap assembly stainless steel (various finishes), incorporating a ceramic cartridge headworks with single lever operating member and pullout spray handset. The spout outlet incorporates a plastic aerator and an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2210329
Expiry date:
31/10/2027
Size:
Stainless steel braided PET lined flexible hose assemblies with ½” BSP (F) captive nut end connections
Marking:
Nokite, WRAS on body
Installation Requirements:
R001 R007 R009 R090
Model:
T12003* The suffix “*” denotes different surface finishes as below: P - Satin PGM - Gunmetal PCOP - Copper PBRS - Brass PMB - Matte black PWH - Painting White
Manufacturer:
Nokite EcoSmart Water Heating Systems (Guangdong) Co., Ltd.
Company Name
Nokite EcoSmart Water Heating Systems (Guangdong) Co., Ltd.
Address
38 South Shunde Avenue Ronggui Foshan Guangdong 528305
Country
China

View All Listings by this Company

Print This Approval


#2210360

Single hole, single outlet (swivel) combination tap assemblies stainless steel (various finishes), incorporating a ceramic cartridge headworks with single lever operating member and pullout spray handset. The spout outlet incorporates a plastic aerator and an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2210360
Expiry date:
31/10/2027
Size:
Stainless steel braided PET lined flexible hose assemblies with ½” BSP (F) captive nut end connections
Marking:
ABI, WRAS on body
Installation Requirements:
R001 R007 R009 R090
Model:
13396,13395, 13394,13393, 13952 & 14351 combination tap assemblies
Factor:
ABI Interiors Pty. Ltd.
Company Name
ABI Interiors Pty. Ltd.
Address
3/128 Kortum Drive,Burleigh Heads, Gold Coast,QLD,4220
Country
Australia

View All Listings by this Company

Print This Approval


#2211012

Single hole, single outlet (swivel) combination tap assembly (brass body - various finishes), incorporating a ceramic cartridge headwork with single leaver operating member. The spout outlet is a pull-out spray type incorporating a plastic aerator. The pull-out hose inlet connector incorporates an approved check valve cartridge, however, , the complete assembly has not been tested to demonstrate it provides backflow prevention Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2211012
Expiry date:
30/11/2027
Size:
Stainless steel braided PEX lined flexible hose with 1/2" BSP captive nut end connections.
Marking:
LOTA On Body
Installation Requirements:
R001 R009 R090
Model:
63557-00X Remark: X means different finishes. Including where X=01, Chrome, X=6801, Matt Black , X=4408, Brushed Brass, X=0402, Brushed Nickel PVD X=5804, Heirloom Silver , X=08, Stainless steel , X=04, Brushed Nickel
Manufacturer:
Xiamen Lota International Co., Ltd.
Company Name
Xiamen Lota International Co., Ltd.
Address
No.61 Xingnan Road, Jimei District, Xiamen, 361022
Country
China
Phone
86-592-6665866

View All Listings by this Company

Print This Approval


#2211018

Single hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating quarter turn ceramic disc headworks with single lever operating members. The spout is a pull-down hose and handset with an optional spray function. The outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2211018
Expiry date:
30/11/2027
Size:
PEX lined flexible hose assemblies with stainless steel braiding with 1/2" BSP (F) captive nut end connection.
Marking:
Gaoao on body
Installation Requirements:
R001 R006 R009 R010
Model:
ZA1143
Manufacturer:
Zhejiang Gaoao Sanitary Ware Co. Ltd.
Company Name
Zhejiang Gaoao Sanitary Ware Co. Ltd.
Address
No.22 Yongda Road, Jiangkou Street, Huangyan District, Taizhou City Zhejiang Province
Country
China

View All Listings by this Company

Print This Approval


#2211016

Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass) incorporating ceramic cartridge headworks and single lever operating members. The spout outlet is a pull-out spray type. The spout inlets incorporate approved check valve cartridges; however, the complete assembly has not been tested to demonstrate it provides backflow prevention. The spout outlets incorporate plastic aerators. The inlet hoses incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2211016
Expiry date:
30/11/2027
Size:
PEX lined flexible hose assemblies with stainless steel braiding with 1/2" BSP captive nut
Marking:
Gaoao on body
Installation Requirements:
R001 R009 R090
Model:
ZA6321 ZA6120 ZA6120SG SG is stainless steel Brushed,
Manufacturer:
Zhejiang Gaoao Sanitary Ware Co. Ltd.
Company Name
Zhejiang Gaoao Sanitary Ware Co. Ltd.
Address
No.22 Yongda Road, Jiangkou Street, Huangyan District, Taizhou City Zhejiang Province
Country
China

View All Listings by this Company

Print This Approval


#2212710

Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass bodies), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet are pull-out spray type, which incorporates aerators and approved single check valve cartridges, however the complete assemblies have not been tested to demonstrate backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 65.°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2212710
Expiry date:
31/12/2027
Size:
Stainless steel braided EPDM lined flexible hoses with 1/2" BSP captive nuts
Marking:
Nabis on operating member
Installation Requirements:
R001 R090
Model:
B08924/ Pratica Lever Pull out kitchen tap & B08930 / Lesina Monobloc Pull out kitchen tap COMBINATION TAP ASSEMBLIES
Factor:
Wolseley UK
Company Name
Wolseley UK
Address
K2 Kingmaker Court, Warwick Technology Park, Warwick
Postcode
CV34 6DY
Phone
01926 705792

View All Listings by this Company

Print This Approval


#2212054

Range of single hole, single outlet pull out spray, combination tap assemblies (brass bodies, various finishes – see models) incorporating ceramic cartridge headworks with single lever operating members controlling the hot and cold and a quarter turn ceramic disk headwork with a dome type operating member controlling chilled water supply. The spout outlet incorporates a plastic aerator. The inlet from the tap to the pull-out spray hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar.

Non-metallic materials and components comply with BS6920 at 60°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2212054
Expiry date:
31/12/2027
Size:
Polyamide braided PEX lined flexible hose assemblies incorporating 3/8" BSP (F) captive nut end connections.
Marking:
Grohe on body
Installation Requirements:
R001 R009 R090
Model:
30601000 - Minta pull-out duo L-spout chrome, 30601DC0 - Minta pull-out duo L-spout supersteel, 30590000 - Minta pull-out duo L-spout chrome, 30590DC0 - Minta pull-out duo L-spout supersteel, 30590KF0 - Minta pull-out duo L-spout matt black. Models added June 2023: 416967045 - Minta pull-out duo L-spout chrome, 416967DC4 - Minta pull-out duo L-spout supersteel, 416967KF4 - Minta pull-out duo L-spout matt black.
Factor:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg 58675 Hemer
Country
Germany
Phone
02372 930
General Email
info@grohe.com

View All Listings by this Company
Manufacturer:
Xiamen Lota International Co Ltd
Company Name
Xiamen Lota International Co Ltd
Address
No. 61 Xing Nan Road Jimei District Xiamen, 361022
Country
China
General Email

View All Listings by this Company

Print This Approval


#2212055

Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating ceramic cartridge headworks with single lever operating member. The outlet is a pull-out spray type and incorporates a plastic aerator. The inlet hoses incorporate stainless steel strainers. Models ZA1147(ZA1147-G, ZA1147-S) have a maximum working pressure of 10.0 bar. All other models have a maximum working pressure of 5.0 bar.

Non-metallic materials and components comply with BS6920 at 60°C

Section:
0445 Combination Tap Assemblies
Section Subtitle:
Pullout spray. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment, alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2212055
Expiry date:
31/12/2027
Size:
Stainless steel braided PEX lined flexible hose assemblies. Models ZA3470YB(ZA3470YB-G): 3/8” captive nut. All other models: ½” captive nut.
Marking:
GAOAO on body
Installation Requirements:
R001 R009 R090
Model:
ZA3470YB & ZA3470YB-G. ZA3470CS & ZA3470CS-G. ZA1147, ZA1147-G & ZA1147-S. ZA3836, ZA3836-G & ZA3836-S. ZA3836CS & ZA3836CS-G. ZA3835 & ZA3835-G. ZA3834CP & ZA3834-G. ZA3834CS & ZA3834CS-G. The following letters denote surface finish: CS: Stainless steel YB: Matte Graphite None/CP: Chrome
Factor:
Zhejiang Gaoao Sanitary Ware Co. Ltd.
Company Name
Zhejiang Gaoao Sanitary Ware Co. Ltd.
Address
No.22 Yongda Road, Jiangkou Street, Huangyan District, Taizhou City Zhejiang Province
Country
China

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 7 of 10

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.