#2211033

Range of floor mounted spout outlets (stainless steel or brass body various finishes) incorporating a plastic aerator. Maximum working pressure: Open outlet use only Maximum operating temperature: 60.0°C

Section:
0682 Combination Tap Assemblies
Section Subtitle:
Spout outlet(s).
WRAS Approval Number:
2211033
Size:
½” BSP (M)
Marking:
VOLA on aerator housing.
Installation Requirements:
R001 R040
Expiry date:
30/11/2027
Model:
VOLA 090FM/700-XX VOLA 090FM-XX VOLA 090FM/900-XX VOLA 090FM/1000-XX Brass and Stainless Steel are available with different surface finishes. Suffix “XX” indicate the number of surface finish and denotes: For Brass: 02=Grey, 04=Blue, 05=Orange, 06=Light Green, 08=Yellow, 09=Dark Grey, 12=Mocca, 14=Bright Red, 15=Dark Blue, 16=Chrome, 17=Gloss Black, 18=White, 19=Natural Brass, 20=Brushed Chrome, 21=Carmine Red, 25=Pink, 27=Matt Black, 28=Matt White, 60=Black, 62=Deep Black, 63=Copper, 65=Gold, 68=Nickel. For Stainless Steel: 40=Stainless Steel, 61=Brushed Black, 64=Brushed Copper, 70=Brushed Gold.
Product Images

Approval Holder:
Vola A/S
Company Name
Vola A/S
Address
Lunavej 2 Horsens
Postcode
8700
Country
Denmark
Phone
+4576284846
General Email
mk@vola.dk

View All Listings by this Company

Print This Approval


#2211036

Chrome plated spout outlet. The spout outlet incorporates a plastic aerator. Maximum operating temperature 65°C.

Section:
0682 Combination Tap Assemblies
Section Subtitle:
Spout outlet(s).
WRAS Approval Number:
2211036
Note:
Open outlet use only.
Size:
8mm LLDPE pipe.
Marking:
Hotspot Titanium on Spout
Installation Requirements:
R001 R006 R009
Expiry date:
30/11/2027
Model:
15453010 Qura Spout
Product Images

Approval Holder:
HotSpot Titanium UK Ltd
Company Name
HotSpot Titanium UK Ltd
Address
90 Rockingham Street Sheffield
Postcode
S1 4EB

View All Listings by this Company

Print This Approval


#2211303

Bath spout (brass body, various finishes - see model) incorporating a plastic aerator. Maximum operating temperature 60°C.

Section:
0682 Combination Tap Assemblies
Section Subtitle:
Spout outlet(s).
WRAS Approval Number:
2211303
Note:
Open outlet use only.
Size:
½” BSP (M).
Marking:
Villeroy & Boch logo on back plate.
Installation Requirements:
R001 R040
Expiry date:
30/11/2027
Model:
Subway 3.0 Range (Bath spout): TVT112001000 The following can be added to the end of the model code to denote finish: 61 (chrome plated), K5 (black matt epoxy painted), 76 (PVD brushed gold), 64 (brushed nickel matt).
Product Images

Approval Holder:
Villeroy & Boch AG
Company Name
Villeroy & Boch AG
Address
Saaruferstraße 1-3 Mettlach
Postcode
66693
Country
Germany
Phone
+49 151 16775778
General Email
Finkler.Marc@villeroy-boch.com

View All Listings by this Company

Print This Approval


#2210053

Range of indirectly heated stainless steel vented hot water storage cylinders. Maximum working pressures: Primary: 6.0 Bar Secondary: 6.0 Bar Maximum operating temperature 75.0°C

Section:
0830 Cylinders
Section Subtitle:
Indirectly Heated - Miscellaneous.
WRAS Approval Number:
2210053
Size:
22mm Compression (Primary and Secondary)
Marking:
Warmflow, model, capacity, max pressures, max temps and other technical information on label on cylinder.
Installation Requirements:
R001 R140 R460
Expiry date:
31/10/2027
Model:
TW170V TW200V TW240V TW290V TR240V TR290V

Approval Holder:
Warmflow Engineering Company Limited
Company Name
Warmflow Engineering Company Limited
Address
Lissue Ind Est Moira Rd Lisburn Northern Ireland BT28 2RF

View All Listings by this Company
Manufacturer:
Warmflow Engineering Company Limited
Company Name
Warmflow Engineering Company Limited
Address
Lissue Ind Est Moira Rd Lisburn Northern Ireland BT28 2RF

View All Listings by this Company

Print This Approval


#2210343

Range of expansion vessels with galvanised or stainless-steel inlets, incorporating butyl rubber diaphragms. The inlet incorporates a plastic strainer (all models, except for WD model). For maximum working pressures please refer to model.

Non-metallic materials and components comply with BS6920 at 70°C

Section:
1000 Expansion Vessels
WRAS Approval Number:
2210343
Note:
Expansion vessels should be installed in the vertical orientation and located so as to minimise the length of any connecting pipework.
Size:
Existing models and models added February 2023: ¾” BSP (M). Models added April 2023: 22mm compression.
Marking:
Existing models and models added February 2023: Reflex, address, pressure rating, volume, serial number and other technical information on an adhesive label on the body. Models added April 2023: Reflex, model, pressure rating, volume, year of manufacture (MM.YYYY) and other technical information on an adhesive label on the body.
Installation Requirements:
R001
Expiry date:
31/10/2027
Model:
The number in the model indicates capacity in litres: Refix DD 2: maximum working pressure 10 bar. Refix DD 4: 10 bar. Refix DD 7: 10 bar. Refix DD 8: 10 bar. Refix DD 12: 10 bar. Refix DD 18: 10 bar. Refix DD 8: 16 bar. Refix DD 12: 16 bar. Refix DD 8: 25 bar. Refix DT 2: 10 bar. Refix DE 2: 10 bar. Refix DE 4: 10 bar. Refix DE 8: 10 bar. Refix DE 12: 10 bar. Refix DE 18: 10 bar. Refix DE 8: 16 bar. Refix DE 12: 16 bar. Refix DE 8: 25 bar. Refix WD 0.165:10 bar. Models added February 2023: Refix DD Galv 2: 10 bar. Refix DD Galv 4: 10 bar. Refix DD Galv 7: 10 bar. Refix DD Galv 8: 10 bar. Refix DD Galv 12: 10 bar. Refix DE 18: 10 bar. Refix DE ‘E’ 2: 10 bar. Refix DE ‘E’ 4: 10 bar. Refix DE ‘E’ 8: 10 bar. Refix DE ‘E’ 12: 10 bar. Refix D DE ‘E’ 18: 10 bar. Models added April 2023: Refix DE 12 (M22C): 10 bar. Refix DE 18 (M22C): 10 bar.

Approval Holder:
Reflex Winkelmann GmbH
Company Name
Reflex Winkelmann GmbH
Address
Gersteinstrasse 19, D-59227 Ahlen
Country
germany

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 934 of 2264

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.