Range of filter cartridges. Maximum working pressure 8.0 Bar. Cold water use only.
Range of filter cartridges. Maximum working pressure 8.0 Bar. Cold water use only.
Range of copper press fittings (‘M’ type crimp profile) and brass threaded adaptor fittings, for use with copper pipe (EN1057). Maximum operating pressure - 16 bar @ 30°C and 10 bar @ 95°C.
Range of press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of “JRG Sanipex MT” compression fittings with EPDM ‘O’-rings for use with “JRG Sanipex MT ECO” multilayer pipes (PE-RT II/Al/PE-RT II). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
B Profile range of 316L & 304 stainless steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe manufactured to EN 10312, for both above and underground use. Joints are achieved by the use of a press fitting tool. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of R-154 stainless steel pressed collars incorporating stainless steel bodies (304L or 316L) and are only to be used with stainless steel pipe. Maximum working pressure for sizes up to DN150 (FCM models) or DN125 (FCI models) is 25.0 bar. Maximum working pressure for size DN200 (FCM models) or DN150 and DN200 (FCI models) is 16.0 bar. Maximum operating temperature 99°C.
‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.
Range of ultrasonic remote transmission water meters with stainless steel body. The products incorporate a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of rotating piston, volumetric in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Cold water use only.
Page 901 of 1118
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.