#2201070

Range of commercial front loading washing machines with flow controlled by solenoid valve and discharged via a type AD air gap arrangement (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with a single check valve assembly (suitable for backflow protection against Fluid Category 2) and PEX lined rubber inlet connections hoses. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
2370 Washing Machines
Section Subtitle:
Clothes. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
2201070
Size:
¾” BSP captive nut (to inlet hoses)
Marking:
Alliance CE & company details, model and other information on adhesive label on body
Installation Requirements:
R001
Expiry date:
31/01/2027
Model:
WM75***** C & WM85***** C RANGE OF WASHING MACHINES

Approval Holder:
Alliance Laundry CE s.r.o
Company Name
Alliance Laundry CE s.r.o
Address
Místecká 1116, 742 58 Príbor
Country
Czech Republic
Phone
+420 556 768 885

View All Listings by this Company

Print This Approval


#2201082

Range of commercial front loading washing machines with flow controlled by solenoid valve and discharged via a type AD air gap arrangement (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with a single check valve assembly (suitable for backflow protection against Fluid Category 2) and PEX lined rubber inlet connections hoses. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
2370 Washing Machines
Section Subtitle:
Clothes. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
2201082
Size:
¾” BSP captive nut (to inlet hoses)
Marking:
GIRBAU on soap draw.
Installation Requirements:
R001
Expiry date:
31/01/2027
Model:
WM75.C & WM85.C
Product Images

Approval Holder:
Girbau S.A.
Company Name
Girbau S.A.
Address
Carretera de Manlleu, KM 1, Vic
Postcode
08500
Country
Spain
Phone
+34659242864
General Email
jsana@girbau.com

View All Listings by this Company

Print This Approval


#2203319

Range of undercounter and passthrough commerical dishwashers with flow controlled by a solenoid valve and discharged via a type AB air gap (verified by test - suitable for backflow protection against fluid category 5). The inlet hose incorporates a stainless steel strainer. Maximum working pressure 4.0 bar. Maximum operating temperature 55°C.

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
2203319
Size:
¾” BSP (F) Captive nut
Marking:
Sammic SL, manufacturers address, model, serial number, date of manufacture (MM/YYYY) and other technical information on Adhesive label on right panel.
Installation Requirements:
R001 R009 R574
Expiry date:
31/03/2027
Model:
Undercounter: AX-51 BC AX-51 BCD UX-50 C UX-50 SC UX-50 BC UX-50 SBC UX-50 BCD UX-50 SBCD Passthrough: AX-100 BC AX-100 BCD UX-120 C UX-120 SC UX-120 BC UX-120 SBC UX-120 BCD UX-120 SBCD Models added April 2025; Passthrough: UX-130 C UX-130 SC UX-130 BC UX-130 SBC UX-130 BCD UX-130 SBCD UX-150 C UX-150 SC UX-150 BC UX-150 SBC UX-150 BCD UX-150 SBCD Utensil: UX-600 C UX-600 BC UX-750 C UX-750 BC UX-1300 C UX-1300 BC
Product Images

Approval Holder:
Sammic S.L.
Company Name
Sammic S.L.
Address
C/Basarte 1 20720 Azkoitia (Gipuzkoa) Spain
Phone
Tel: +94 315 7234 Fax: +94 381 2883

View All Listings by this Company

Print This Approval


#2205080

Range of UV disinfection units with stainless steel bodies & quartz tubes. All models incorporate a spherical valve on the drain outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C

Section:
2411 Disinfection Equipment
Size:
1” BSP, 1½” BSP & 2” BSP male inlet and outlet.
Marking:
Hydrotec, model, WRAS and technical information on adhesive label on body.
Installation Requirements:
R001 R150 R170 R511
Expiry date:
31/05/2027
Model:
HydroWELL Compact 1E DN40. HydroWELL Compact 2E DN25. HydroWELL Compact 5E DN40. HydroWELL Compact 7E DN50. HydroWELL Compact 10E DN50.

Approval Holder:
Hydrotec International Water Treatment Limited
Company Name
Hydrotec International Water Treatment Limited
Address
38 Main Street Swords Country Dublin
Country
Ireland

View All Listings by this Company

Print This Approval


#2209040

Range of floor or wall mounted water refill units. The flow is controlled via self-closing headworks with a dome type push button operating member. The outlet incorporates a bottle filling outlet with an aerator. The inlet incorporates an isolation valve, a drain valve and an approved double check valve suitable for backflow protection against fluid category 3. Maximum working pressure – 5.0 Bar, cold water use only.

Section:
2420 Water Coolers
Section Subtitle:
Drinking.
WRAS Approval Number:
2209040
Size:
25mm compression fitting
Marking:
Our only world + WRS 01 on plate on body
Installation Requirements:
R001 R430 R511
Expiry date:
30/09/2027
Model:
WRS 01 (Available in both floor or wall mounted variants).
Product Images

Approval Holder:
Our Only World
Company Name
Our Only World
Address
35 Higher Tristram Polzeath Wadebridge Cornwall PL276TF

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 78 of 189

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.