Range of carbon block water filters and housings. Maximum working pressure 10.5 bar. Cold water use only.
Range of water filter housings with plastic heads and bodies (various colours - see model), incorporating NBR ‘O’-rings (158087/088/207/208/218/219/261 models only) or with EPDM ‘O’-rings (all other models). Big Blue for Cartridges - Maximum working pressure 6.9 bar (10” filter housings) and 6.2 bar (20” filter housings). Maximum working temp 38°C. All other models - Maximum working pressure 8.62 bar. Maximum working temp 52°C.
Carbon block filter cartridge with plastic body. The cartridge may be installed with a manifold (filter head) for use with PE tubing manufactured to BS 1972. Maximum working pressure 8.6 bar. Cold water use only
‘Multi Press Leak M.P.L’. range of fittings (pressing profile TH and U) for use with Alpex Duo XS multi-layered pipe. For above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Dual flush WC outlet valve with an ABS body, incorporating a silicone seal & internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
Range of urinal flushing mechanisms with a solenoid valve controlling the flow. The valves are controlled via an infra-red sensor. The inlet incorporates a stainless steel strainer and flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
A range of under sink electrically heated vented water heaters (cased and insulated) with a stainless-steel cylinder incorporating a temperature sensor and a float switch (not flow control) Maximum operating temperature 98°C.
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. The primary circuit has a maximum working pressure of 2.5 bar. The secondary circuit has maximum working pressure of 10.0 bar. Maximum supply temperature is 60°C. Maximum operating temperature of secondary circuit is 85°C.
Hydraulic block assembly comprising a flow sensor, primary pump assembly, pressure relief valve preset at 3.0 bar and plate heat exchanger. Maximum working pressures: secondary = 10.0 bar and primary = 2.5 bar. Maximum operating temperature 80°C.
‘Aquila V4 C1’ range of water meters (brass or bronze bodies) with a plastic working chamber, flow regulator and impellor, and either NBR or EPDM ‘O’-rings. The products are supplied with loose NBR/fibre flange gaskets. Maximum working pressure 16.0 bar. Cold water use only.
A range of water meters incorporating brass or plastic bodies (See models), EDPM ‘O’-rings, plastic strainer on the inlet and a plastic impellor. Maximum working pressure 16.0 bar. Maximum working temperature 85°C (brass bodies) or cold water use only (plastic bodies)
Range of water meter assemblies which incorporating DZR brass bodies, spherical valve and pressure reducing valve (1.5 to 6.0 bar range). The products incorporate two approved, in-line single check valve cartridges, (verified by test, suitable for backflow protection against Fluid Category 3). Fitting is also supplied with a pressure guage. Maximum working pressure 10.0 bar. Cold water use only.
Range of pushfit hose connectors with either plastic (white or black) or chrome plated brass bodies and EPDM ‘O’-rings. SHCV prefix models incorporate screwdriver operated servicing valves. All pushfit connections are for use with PEX pipe (manufactured to BS7291-3) and copper pipe (manufactured to EN1057). Barbed end connections are not approved for use with any hose. Chrome plated brass body models are also for use with PB pipe (manufactured to BS7291-2). Maximum working pressure 10.0 bar (servicing valve models only). Barbed end connections are open outlet use only. Cold water use only.
Range of water hammer arrestor’s incorporating brass bodies (various finishes). The 525152 model is supplied with a reinforced captive nut. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C. For products manufactured from June 2023 Maximum operating temperature 85°C
Range of flexible joints incorporating an EPDM (inner & outer) joint with a steel reinforcing ring and two carbon steel flanges. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
Range of flow control valves for domestic hot water with plastic bodies and EPDM ‘O’-rings The products incorporate a motor which adjusts the flow, a flow sensor which measures the flow rate and a plastic filter on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Pressure gauge with brass body and a plastic case. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C
Range of bidet spray kits comprising of a hand set with self-closing trigger, wall bracket, flexible hose assembly, thermostatic blending valve and isolation valve. Maximum working pressure 5 bar. Maximum working temperature 60°C
‘e-SH’ range of centrifugal booster pumps with a blue polymer coated stainless steel body, stainless steel impeller and EPDM ‘O’-rings. Maximum working pressure 12.0 bar. Cold water use only.
Range of shower kits, shower outlets and shower hoses. The shower handsets and overhead shower inlets incorporate a plastic flow regulator. Maximum operating temperature 45°C.
Page 70 of 177
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.