‘HE-705X & HE-715X’ ranges of brass crimp fit fittings incorporating EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057-2006). HE-7052/7053/7058/7059 & HE-7152/7153/7158/7159 models also incorporate a NBR gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
VSH XPRESS Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PVC-u solvent weld and threaded union fittings incorporating an EPDM ‘O’-ring. For use with PVC-u pipe manufactured to ISO 1452 and DIN 8063. Maximum working pressure 10.0 bar. Cold water use only.
‘Xpress’ range of press fit fittings with copper or brass bodies and EPDM ‘O’-rings. For use with copper tube manufactured to EN1057. For above ground ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Pexal range of brass press fittings with EPDM ‘O’-rings for use with copper pipe EN1057. Model VS0171373 incorporates 90° copper elbow (chrome plated) Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
‘AF’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). The AF14 and AF15 tap connector models incorporate an EPDM washer. Maximum working pressure 16.0 bar. Maximum working temperature 85˚C
Low profile mechanical seal intended for the internal repair of pipe joints. The system incorporates two stainless steel compression rings and an EPDM seal. For above and below ground use. Maximum working pressure 22.5 bar. Cold water use only.
Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.
‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.
Range of water meters with a brass body, EPDM ‘O’-rings and seal. The products incorporate an internal plastic strainer and an optional combined plastic and stainless-steel strainer on the inlet. Maximum working pressure 16.0 bar. Cold water use only
Page 57 of 220
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.