Directory Search Results

Print List

#2010310

Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.

Section:
1350 Heat Exchangers
Size:
See model
Marking:
Uponor, model no, serial no & date of manufacture (DD.MM.YYYY) on inside cover.
Installation Requirements:
R001 R140 R360
Expiry date:
31/10/2025
Model:
Uponor Combi Port base XU: 1095642 15l/min 1095643 21l/min 1095644 29l/min Optional ball valve set 101802 for models 1095644 & 1095642 Uponor Combi Port PRO XU: 1095636 15l.min 1095637 21l/min Optional Ball valve set 1037536
Product Images

Approval Holder:
Uponor GmbH
Company Name
Uponor GmbH
Address
Industriestrasse 56, Hassfurt
Postcode
97437,
Country
Germany
Phone
0034916853600
General Email
mariaisabel.fernandez@uponor.com

View All Listings by this Company

Print This Approval


#2011035

Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2011035
Note:
There are no pipework connections on this product to facilitate the filling of the space heating circuit. The installer must provide this separately.
Size:
Domestic hot water and District heating circuits: ¾” BSP (M) inlet/outlet. Space heating circuit: ¾” BSP captive nut inlet/outlet.
Marking:
YGHP on front cover. YGHP, model number, company address and technical info on adhesive label on side of body.
Installation Requirements:
R001 R140 R360 R511
Expiry date:
30/11/2025
Proviso:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
YGINDRADSTD33/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 33kW / HTG 10kW. YGINDRADSTD40/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 40kW / HTG 10kW. YGINDRADSTD50/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 50kW / HTG 10kW. YGINDRADSTD60/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 60kW / HTG 10kW. YGINDRADSTD75/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 75kW / HTG 10kW. YGINDRADSTD90/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 90kW / HTG 10kW. YGINDRADSTD120/10.1 - YGHP INDIRECT STANDARD HIU (RADIATORS) - DHW 120kW / HTG 10kW. Models added March 2021: YGINDUFHSTD33/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 33kW / HTG 10kW YGINDUFHSTD40/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 40kW / HTG 10kW YGINDUFHSTD50/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 50kW / HTG 10kW YGINDUFHSTD60/10.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 60kW / HTG 10kW YGINDUFHSTD75/15.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 75kW / HTG 15kW YGINDUFHSTD90/15.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 90kW / HTG 15kW YGINDUFHSTD120/30.1 - YGHP INDIRECT STANDARD HIU (UFH) - DHW 120kW / HTG 30kW
Product Images

Approval Holder:
YGHP Ltd
Company Name
YGHP Ltd

View All Listings by this Company

Print This Approval


#2011037

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2011037
Note:
A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Size:
½” BSP male inlet and outlet (DHW). ¾” BSP male inlet and outlet (CH).
Marking:
Lukey on adhesive label on front.
Installation Requirements:
R001 R140
Expiry date:
30/11/2025
Model:
Lukey solution HE (18kW CH & 26kW DHW). Lukey solution HE+ (18kW CH & 26kW DHW). Lukey solution HES+ (18kW CH & 26kW DHW). Lukey solution CBU (18kW CH & 26kW DHW). Beginning February 2021 the models will be named: Lukey 28 HE (18kW CH & 26kW DHW). Lukey 28 HE+ (18kW CH & 26kW DHW). Lukey 28 HES+ (18kW CH & 26kW DHW). Lukey 28 CBU (18kW CH & 26kW DHW).
Product Images

Approval Holder:
Lukey Cassette Boilers (UK) Ltd.
Company Name
Lukey Cassette Boilers (UK) Ltd.
Postcode
BH24 2BB

View All Listings by this Company
Manufacturer:
Lukey Cassette Boilers (UK) Ltd.
Company Name
Lukey Cassette Boilers (UK) Ltd.
Postcode
BH24 2BB

View All Listings by this Company

Print This Approval


#2012051

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2012051
Note:
Please note that the inlet pipework connects to the flow sensor, no fittings or valves prior to this are supplied. Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with Schedule 2 paragraph 7 of the Water Supply (Water Fittings) Regulations 1999.
Size:
½” BSP (M) inlet and outlet Secondary Circuit. ½” BSP (M) replenishing valve. ¾” BSP(M) inlet and outlet primary circuit.
Marking:
Strom on front of body. Model and technical info on adhesive label on side of body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/12/2025
Model:
Strom E range comprising of models: SBSP7C, SBSP11C & SBSP15C. SBTP18C, SBTP21C & SBTP24C. The number in model indicates kW rating.

Approval Holder:
STROM LTD
Company Name
STROM LTD

View All Listings by this Company

Print This Approval


#2011322

Range of overhead shower outlets with brass bodies (various finishes), with a ball joint, EPDM ‘O’-rings and a NBR seal. The inlet incorporates a plastic flow regulator. Maximum operating temperature 60°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2011322
Note:
Open outlet use only.
Size:
½” BSP (F)
Marking:
THG on nut
Installation Requirements:
R001 R040
Expiry date:
30/11/2025
Model:
G00.xxx.281EP/W Where xxx will be replaced by the following finishes A01 - Poli A02 - Chromé B01 - Nickel brilliant C01 - Nickel mat C02 - Chromé mat C03 - Chromé satiné C05 - Nickel satiné C47 - Nickel Fumé D01 - Bronze clair D05 - Bronze clair mat D13 - Carbon D24 - Aranja F01 - Doré brillant F03 - Doré satiné F07 - Doré mat non vernis F18 - Argent Rhodié F19 - Argent mat Rhodié F27 - Or rose F30 - Or pâle F31 - Or pâle mat F32 - Or pâle satiné F33 - PVD couleur bronze F34 - PVD couleur bronze brown H03 - Vieil argent brillant H06 - Cuivre rouge mat H07 - Vieux cuivre rouge mat H17 - Aranja mat H21 - Cuivre rouge non verni H24 - Vieux cuivre rouge brillant H27 - Bronze satiné H28 - Vieux nickel H30 - Vieil argent mat non verni H49 - PVD couleur laiton H50 - PVD couleur laiton mat H52 - PVD couleur doré H53 - PVD couleur doré mat H55 - PVD couleur nickel H56 - PVD couleur nickel mat H60 - PVD couleur blush mat H62 - PVD couleur blush H64 - PVD couleur graphite H65 - PVD couleur graphite mat H66 - PVD couleur amber H67 - PVD couleur umber mat
Product Images

Approval Holder:
THG Paris
Company Name
THG Paris
Address
35 rue Tournière Béthencourt sur Mer
Postcode
80130
Country
France
Phone
+33 3.22.60.20.80
General Email
cvallee@thg.fr

View All Listings by this Company
Manufacturer:
THG Paris
Company Name
THG Paris
Address
35 rue Tournière Béthencourt sur Mer
Postcode
80130
Country
France
Phone
+33 3.22.60.20.80
General Email
cvallee@thg.fr

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 452 of 699

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.