Range of deck mounted thermostatic shower mixers with brass bodies (chrome plated), incorporating ceramic disc headworks with dome type operating members controlling the flow and a lockable self-cancelling diverter to shower outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Spout outlet incorporates a plastic flow straightener. Both inlets incorporate a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection) and stainless-steel strainers. Model DYN106 is supplied with a shower hose and shower handset, all other models are supplied with a shower hose, shower handset, riser rail and soap dish. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Three-hole, single outlet (fixed) combination tap assembly with brass body (various finishes), incorporating quarter turn ceramic disc headworks with dome (cube) type operating members. Each inlet incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlets incorporate a plastic aerator. Product is supplied with stainless steel braided, PEX lined connection hoses and pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (swivel) combination tap assembly with brass body (various finishes) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted (swivel) spout outlets with chromium plated brass bodies, EDPM ‘O’-rings and a plastic flow straightener. DJ suffix models have a double swivel arm. Maximum operating temperature 65°C.
‘Quattroselect’ range of chemical dosing units incorporating a lockable self-closing trigger assembly and a self-closing bottle filler assembly which control the flow. The products are supplied with an approved double check valve assembly at the inlet (suitable for backflow prevention against fluid category 3). Maximum working pressure 5.8 bar. Cold water use only.
Range of brass compression fittings for use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of capillary end feed bronze fittings for use with copper tube (manufactured to BS EN 1057). 15mm – 54mm fittings have a maximum working pressure of 25.0 bar. 67mm – 108mm fittings have a maximum working pressure of 16.0 bar. Maximum operating temperature 100°C.
WC dual flush drop valve comprising of a plastic body and silicone seating washer. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water only.
Range of WC flapper valves with a silicone seal, ABS body and internal overflow. The device is operated via a plastic chain to be connected to a cistern handle. Cold water use only.
Dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of WC dual flush drop valve with plastic body silicone rubber seal and NBR rubber ‘O’-ring. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water only.
Range of WC dual flush drop valve with plastic body silicone rubber seal and NBR rubber ‘O’-ring. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.
Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.
Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.
Q4000 range of water meters incorporating stainless steel bodies, FKM rubber gasket and grey epoxy resin liner. Maximum working pressure 16.0 bar. Cold water use only.
Wall bracket with a brass body (chrome plated) and EPMD ‘O’-rings. Maximum operating temperature 85°C.
Screw down pattern, angled solation valve with a dome type operating member, DZR brass body and an EPDM gasket and ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of 2,3 or 4 way manifolds incorporating a nickel plated brass body with non-rising spindle stop valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Page 46 of 508
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.