#2305911

Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.

Section:
1530 Miscellaneous Fittings
Size:
CPS/ITS/LPS/RPS: BRASS CW 617N: ¼" BSPP (M). S/S EN 14408: ½" BSPP (M) w/vent port. ½" BSPT (M). ½" BSPT (M) (short). ½" NPT (M). Plastic: ⅜" BSPP (M). DPS: BRASS CW 617N: ½" BSPT (M) w/vent hole. 15.5mm w/vent hole. S/S EN 1.4401: ½" BSPT (M) w/vent hole. ½" BSPP (M). Housing only S/S (EN 1.4408): 2x ⅛" NPT (F). End connections for housing only: AISI 316 6mm compression, 6mm and 8mm tube. MFS, VFS (COMPOSITE FLOWPIPE): FLOWPIPE ONLY: 1”, 1¼”, 1½” BSPP (M). END CONECTIONS: BRASS CW 617N: ½", ¾" BSPP (M). ¾", 1", 1¼" BSPT (M). ½", ¾", 1", 22mm, 28mm SWEAT. S/S EN 1.4401: ¾", 1", 1¼" NPT (M). 1", 1¼" BSPT (M). MFS, VFS (S/STEEL FLOWPIPE): FLOWPIPE ONLY (EN 1.4408): ¾", 1", 1¼" BSPP (M). ¾", 1", 1¼" NPSM (M). 1" FLANGE. END CONNECTIONS: BRASS CW 617N: ½", ¾", 1" BSPT (M). ¾", 1", 22mm & 28mm SWEAT. S/S EN 1.4401: ¾", 1" BSPT (M). ¾", 1" NPT (M). VFI: CAST IRON OR S/STEEL EN 1.4408 FLANGED: DN18/25/32 (1¼"). DN40/50 (2"). DN65/80/100. S/S EN 1.4401: 1”, 1¼" BSPT (M). 1, 1¼" NPT (M).
Marking:
VFI models: Grundfos and model type (VFI) on adhesive label on sensor. Grundfos on flow pipe. All other models: Grundfos on top of sensor housing. Model type (ITS/LPS/RPS/MFS/VFS) on adhesive label on sensor.
Installation Requirements:
R001
Expiry date:
31/05/2028
Model:
Model: CPS, ITS, LPS or RPS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF CPS, ITS, LPS or RPS with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII CPS model added February 2024. Fortron body material added June 2024. Product: [A] Must be CPS, ITS, LPS or RPS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E or I, second and third character have no importance for drinking water* Materials: [G] Must be either -B, -S, -I, -D or -- Connection: [H] Must be either 03A, 03B, 03N, 02P, 01K, 16P, 66P or --- Packaging: [I] Of no importance for drinking water* ------ DPS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF DPS with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII EPDM O-rings and EPDM anti-sedimentation sealing cap added June 2024 Product: [A] Must be DPS Range and unit: [B] Of no importance for drinking water* Gen.: [C] All characters allowed except 4 and 5 Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E or I, the second must not be A. The third character has no importance for drinking water* character have no importance for drinking water* Materials: [G] Must be either -B, -S, S-, SS or -- Connection: [H] Must be either 06C, 06T, 08T, 01L, 24N, 63B, 64S or --- Packaging: [I] Of no importance for drinking water* ------ MFS or VFS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF MFS or VFS with or without composite flow pipe accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be MFS or VFS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be A or E, second and third character have no importance for drinking water* Materials: [G] Must be either C-, CB, CS or -- Connection: [H] Must be either 03P, 03S, 04B, 04N, 04P, 04S, 05B, 05N, 05P, 05S, 07B, 07N, 07P, 09P, 01K, 15K, 18K, 22S, 26R, 28S or --- Note: 04N, 05N and 07N only in combination with CS [G] Packaging: [I] Of no importance for drinking water* ------ MFS or VFS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF MFS or VFS with or without stainless steel flow pipe accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be MFS or VFS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be A or E, second and third character have no importance for drinking water* Materials: [G] Must be either QB, QS, Q- or -- Connection: [H] Must be either 03B, 04B, 04M, 04N, 04P, 04S, 05B, 05M, 05N, 05P, 05S, 07M, 07P, 01K, 01L, 102, 22S, 28S, 51G or --- Packaging: [I] Of no importance for drinking water* ------ VFI sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF VFI with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be VFI Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E, second and third character have no importance for drinking water* Materials: [G] Must be either S-, SG, SS or -- Connection: [H] Must be either --F, --P, 05B, 05N, 07B, 07N, 07P, 09P, 30F, 31F, 32F, 33F, 35F, 37F or 42F Packaging: [I] Of no importance for drinking water* ------ Where: Code for sealing [F]: 1st character: “A” means EPDM O-rings and EPDM sealing sleeve. “E” means EPDM O-rings. “I” means EPDM O-rings and EPDM anti-sedimentation sealing cap Code for material [G]: 1st character: “C” means composite flow pipe. “Q” means flow insert and (except service sets) also a stainless steel flow pipe. “S” means stainless steel adapter (for DPS) or flow pipe. “-“ means no adapter (for DPS) or flow pipe. 2nd character: "B" means brass (fitting). “D” means Fortron (fitting) “G” means cast iron (flange). “I” means composite (fitting). "S" - means stainless steel (fitting or flange). “-“ means no further accessories included. Code for connection (H): 1st two characters: “01” means 10 mm. “02” means ¼”. “03” means ½”. “04” means ¾”. “05” means 1”. “06” means 6 mm. “07” means 1¼”. “08” means 8 mm. “09” means 1½”. (Internal note - this is on a flow pipe connection) “15” means 15 mm. “16” means ⅜”. “18” means 18 mm. “22” means 22 mm. “24” means ⅛”. “26” means 42 mm. “28” means 28 mm. “30” means DIN PN25/40 DN18/25/32, ANSI B16.5 Class 300 - 1¼". “31” means DIN PN16/25/40 DN40, ANSI B16.5 Class 300 - 2". “32” means DIN PN16/25/40 DN50, ANSI B16.5 Class 300 - 2". “33” means ISO/DIN PN25/40 DN65. “35” means ISO/DIN PN25/40 DN80. “37” means ISO/DIN PN16 DN100. “42” means ISO/DIN PN25/40 DN100. “51” means 1" / ¾". “63” means ½" and ventilation opening. “64” means 15.5 mm and ventilation opening. “66” means ½” and M8 ventilation port “--” means no accessories included and thus implicitly the dimension of the sensor connection, which for DPS, ITS, LPS, MFS, RPS and VFS is 10 mm (of no importance for drinking water). For VFI this is used for service sets, which includes the sensor and the bluff body, but not the flow pipe (of no importance for drinking water). 3rd character: “A” means BSPT (short). “B” means BSPT. “C” means Compression. “F” means flange. “K” means standard clip included (of no importance for drinking water). “L” means special clip included (of no importance for drinking water). “M” means NPSM. “N” means NPT. “P” means BSPP. “R” means union not (union nut included but no fittings included). “S” means sweat. “T” means hose connector. “2” means both standard clip and special clip included (of no importance for drinking water). “-“means no accessories included and thus implicitly the connection type of the sensor, which for DPS, ITS, LPS, MFS, RPS and VFS is a clip (of no importance for drinking water). Further details on the nomenclature: * All characters are allowed NOTE - For customer-specific numbers, GG/HHH/IIII in the saleable code is replaced by the customer name. However, the customer-specific products are still covered if they meet the requirements specified in the standard sales code.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#2304909

Range of circulator pumps with brass bodies, plastic impellor, and EPDM ‘O’-rings and seals. The COMFORT 15-14 BX prefix models incorporate a screwdriver operated isolation valve on the inlet and a non-return valve at the outlet. These are housed within 1” BSP (M) x ½” BSP (M) adaptors. Maximum working pressure 10.0 Bar. Maximum operating temperature 95°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2304909
Size:
COMFORT 15-14 B prefix models: ½” BSP (F). COMFORT 15-14 BX prefix models: 1” BSP (M).
Marking:
Grundfos on body. Model on adhesive label on body. Flow arrow on the isolation valve.
Installation Requirements:
R001
Expiry date:
30/04/2028
Model:
COMFORT 15-14 B PM GB, COMFORT 15-14 BX PM GB, COMFORT 15-14 BDT PM GB, COMFORT 15-14 BXDT PM GB, COMFORT 15-14 BA PM GB, COMFORT 15-14 BXA PM GB. Models added October 2024: COMFORT 15-14 B T GB, COMFORT 15-14 B GB, COMFORT 15-14 BX T GB, COMFORT 15-14 BX GB, COMFORT 15-14 B TDT GB, COMFORT 15-14 BX TDT GB, COMFORT 15-14 B TA GB, COMFORT 15-14 BX TA GB. Model keycode: Pump type: COMFORT, 15: Length 80mm, 14: Maximum head [14 dm], B: Brass pump, X: Fittings included (see product description), Blank = No fittings, Control mode, 1-4 characters. Blank: Basic (always on), T: Thermostat, DT: Digital timer, A: AutoAdapt. PM: Permanent magnet (Designation removed October 2024). GB: Sales region.
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#2303041

Range of multistage pumps (VL and CL series) and submersible pumps (VN, CN, ES and CS series) with stainless steel bodies and impellers and NBR gaskets and ‘O’-rings. Maximum working pressure 15.0 bar (VL and CL series pumps only).

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2303041
Size:
VL and CL series: 1 ¼” Female BSP inlet x 1 ½” Female BSP outlet. VN and CN series: 1 ¼” Female BSP outlet - 2" Female BSP outlet. ES and CS series: 1 ¼” Female BSP outlet.
Marking:
Franklin electric Srl logo, WRAS, model no., serial no., pressure and date of manufacture (DD/MM/YYY) on body.
Installation Requirements:
R001 R415
Expiry date:
31/03/2028
Model:
VNx1/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D, x1CN/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D, VLx1/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D, x1CL/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D, ESx1/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D, x1CS/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D. Where: VN, CN, VL, CL, ES, CS = Series name. VN/VL/ES series “E-TECH” brand CN/CL/CS Series “FPS” brand x1 = Nominal Flow: 3, 5, or 9. (9 is not available on ES and CS models) xx2 = number of impellers: 2 to 10 (VN/CN & VL/CL models), 2 to 8 (ES/CS models), depending on Nominal Flow and Frequency. I = Material: St/Steel 1.4301 (AISI304). xxx3 = Motor Power (kW x 10): 005, 007, 009, 011… x4 = Supply (no phase): T (three phase), M (single phase). x5 = Frequency (Hz): 5 (50 Hz), or 6 (60 Hz). x6 = Motor Configuration: L (Bi-phase, 90° single-phase), D (Three-phase, triangle), or Y (Three-phase, star). N = Mechanical seal elastomer: N = NBR. x7 = Mechanical Seal surface: 1 (Graphite / Silicon Carbide), or 2 (Silicon Carbide). x8 = Float Switch: 0 (without). B = Cable type: B (Blue). x9 = Cable size: A (4G1), B (4G1.5), C (3G1), or D (3G1.5). x10 = Cable length: O: 20m - VN/CN and ES/CS models, E: 5m - VL/CS models. x11 = Control Panel (not in contact with liquid): 0 (without), or 1 (connected - VN/CN models only). N = Nude terminal (not in contact with liquid). x12 = Option (only on VN/CN models) - Discharge head (”): Empty (1¼” Nickel plated brass), I (1¼” inox), or J (2” inox). D = Drinking water approved.
Product Images

Approval Holder:
Franklin Electric SRL
Company Name
Franklin Electric SRL
Address
Via Asolo 7 Dueville Vicenza 36031
Country
Italy
Phone
+39 0444 360366
General Email
info.it@fele.com

View All Listings by this Company

Print This Approval


#2305073

Range of vertical multistage pumps with either stainless-steel bodies (“N” versions) or cast iron bodies with a black electrodeposition coating (“G” versions), stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: EV30, EV45, 30VR & 45VR models - 32.0 bar, EV65, EV95, 65VR & 95VR models - 25.0 bar. Max operating temperature: Stainless steel (“N” versions) - 100°C. Cast iron (“G” versions) - Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2305073
Size:
DN65 - DN100
Marking:
Franklin electric S.r.l logo, serial number, model number, date of manufacture (DD/MM/YYYY) and pressure on data plate on body.
Installation Requirements:
R001 R415
Expiry date:
31/05/2028
Model:
EV and VR ranges. Code example (EV range): EV 30 /13 A B C D E F G H J K L M N. Where: EV = Pump model EV (EV = E-Tech “brand”). 30 = Rated flow [m³/h] (varies: 30-95). /13 = No. of stages/impellers. (See model and stages below for more detail). A = No. of trimmed impellers, if "Empty" = none. B = Flange type: "F" - round. C = Materials: "G" - (cast iron/Stainless steel); "N" - (AISI316/EN1.4401). D = Motor power (kW x 10). E = Motor type: “Vacuum” (pump without motor), "T" - 3-phase; "M" - 1-phase. F = Frequency: "5" - 50Hz; "6" - 60Hz. G = No. of motor poles: "Empty" - 2 poles; "4" - 4 poles. H = Mechanical Seal: "B" (balanced). J = Elastomeric and mechanical seal material: E1 (SiC-Carbon Graphite-EPDM) or E2 (SiC-SiC-EPDM). K = “IE…” motor efficiency class IEC60034-30, where applicable, “Vacuum” (pump without motor). L = “Vacuum” standard version,“M” (oversized motor). M = "Vacuum” - standard version. N = Motor voltage, “Vacuum” (pump without motor). EV30: stage from 1 to 13 (50Hz) and from 1-1A to 8 (60Hz); EV45: stage from 1-1A to 13-2A (50Hz) and from 1-1A to 7 (60Hz); EV65: stage from 1-1A to 8 (50hz) and from 1-1A to 5-1A(60 hz); EV95: stage from 1-1A to 6 (50Hz) and from 1-1A to 4-2A (60Hz). Code example (VR range): 30 VR0700 A B C X-XXXX. Where: 30 = Rated flow [m³/h] (varies: 30-95). VR = Pump model (VR = FPS “brand”). 07 = No. of stages/impellers. (See model and stages below for more detail). 00 = Impeller trim: 00 = no trim, A1 = 1A (one trimmed impeller), A2 = 2A (two trimmed impellers). A = Materials: "G" - (cast iron/304SS); "N" - (AISI316/EN 1.4401). B = Flange type: "F" - round. C = Mechanical Seal: “A” - (BQBE, BE1); “B” - (BQQE, BE2). X-XXXX = Combination of numbers and letter relating to frame, speed, motor and electronics (does not affect water pathways). Last two digits can be empty for versions without a motor. 30VR: stage from 1 to 13 (50Hz) and from 1-1A to 8 (60Hz); 45VR: stage from 1-1A to 13-2A (50Hz) and from 1-1A to 7 (60Hz); 65VR: stage from 1-1A to 8 (50hz) and from 1-1A to 5-1A (60Hz); 95VR: stage from 1-1A to 6 (50Hz) and from 1-1A to 4-2A (60Hz).
Product Images

Approval Holder:
Franklin Electric SRL
Company Name
Franklin Electric SRL
Address
Via Asolo 7 Dueville Vicenza 36031
Country
Italy
Phone
+39 0444 360366
General Email
info.it@fele.com

View All Listings by this Company
Manufacturer:
Franklin Electric SRL
Company Name
Franklin Electric SRL
Address
Via Asolo 7 Dueville Vicenza 36031
Country
Italy
Phone
+39 0444 360366
General Email
info.it@fele.com

View All Listings by this Company

Print This Approval


#2311900

Single stage centrifugal pump, with plastic impellers. The pump is equipped with ceramic bearings; the body and shaft are made of stainless steel. The product is supplied with loose fibre/NBR inlet/outlet gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2311900
Size:
2” BSP (M) inlet/outlet
Marking:
Grundfos and Grundfos logo, type, model, production number, technical info and manufacturing country on data plate on top of motor housing. Flow arrow on body.
Installation Requirements:
R001 R415
Expiry date:
30/11/2028
Model:
UPS 32 -100 N 180

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 432 of 809

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.