Heaters

Section Code 1465 : Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.

Back To Directory Sections

#240502715

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240502715
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DHW: 15mm compression. CH: 22mm compression
Marking:
Range name on front cover, Model, Max pressure, Max temperature and product information on data plate on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2029
Model:
Models without a filing loop supplied: 0010016113 - Glow-worm ESSENTIAL 24c -A (H-GB) 0010016115 - Glow-worm ESSENTIAL 28c -A (H-GB) 0010016127 - Heatline CAPRIZ 2 24c -A (H-GB) 0010016128 - Heatline MONZA 2 24c -A (H-GB) 0010016129 - Heatline CAPRIZ 2 28c -A (H-GB) 0010016130 - Heatline MONZA 2 28c -A (H-GB) 0010021401 - Glow-worm EASICOM 3 24c -A (H-GB) 0010021402 - Glow-worm EASICOM 3 28c -A (H-GB) 0010020392 - Vaillant VUW 256/6-3 (H-GB) ecoFIT sustain 825 0010020393 - Vaillant VUW 306/6-3 (H-GB) ecoFIT sustain 830 0010020394 - Vaillant VUW 356/6-3 (H-GB) ecoFITsustain 835 Models with a filling loop supplied: 0010020389 - Vaillant VUW 256/6-3 (H-GB) ecoFIT pure 825 0010020390 - Vaillant VUW 306/6-3 (H-GB) ecoFIT pure 830 0010020391 - Vaillant VUW 356/6-3 (H-GB) ecoFIT pure 835 0010019813 - Vaillant VUW 306/6-3 (P-GB) ecoFIT pure 830 P 0010021204 - Glow-worm BETACOM 4 24c -A (H-GB) 0010021205 - Glow-worm BETACOM 4 30c -A (H-GB) 0010021404 - Glow-worm ULTIMATE 3 30c -A (H-GB) 0010021405 - Glow-worm ULTIMATE 3 35c -A (H-GB) 0010027591 - Glow-worm ENERGY 2 30c -A (P-GB) 0010035896 - Glow-worm ENERGY 7 25c (H-GB) 0010035897 - Glow-worm ENERGY 7 30c (H-GB) 0010035898 - Glow-worm ENERGY 7 35c (H-GB)

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company

Print This Approval


#240502720

Range of wall mounted combination boilers providing domestic hot water (DHW) via a plate heat exchanger and pressurised central heating (CH) system. Incorporating a pressure relief valve set at 3.0 bar and expansion vessel. Supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressure Primary circuit (CH) 2.5Bar, Secondary circuit (DHW) 10.0 Bar Maximum operating temperature 90.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240502720
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Primary circuit (CH) ¾” BSP (M), Secondary circuit (DHW) ½” BSP (M).
Marking:
NAVIEN on front of boiler. NAVIEN, Model Number, Max Pressure and other technical info on adhesive label on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2029
Model:
NCB300-28K NCB300-37K NCB300-41K Model added July 2024 NCB300-30K

Approval Holder:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company
Manufacturer:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company

Print This Approval


#240704704

Range of wall mounted gas fired condensing instantaneous water heaters. Maximum working pressure 10.0bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240704704
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP(M) for 10-12L & 14~17L/min (Flow rate) ¾” BSP(M) for 22~26L/min (Flow rate)
Marking:
Company Logo Vanward, model, pressure, tempeture and and other technical info on adhesive label on side panel.
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
10~12L balance type & forces exhaust type gas water heater: JSG=balance type gas water heater, JSQ=forces exhaust type gas water, a= nominal heat input(kW) (fixed from 20, 22 to 24), b=volume (fixed from 10, 11 to 12), STc=Sd= the type of casing (c fixed from 27, 28 to 29, d fixed from 21, 25, 22, 21B, 23, 24, 25(A), 25(B), 26, 27, 28, 31, 32, 34 to 35) Casing 1: ST27, S21, Casing 2: ST28, S25, Casing 3: ST29, S22, Casing 4: S21B, Casing 5: S23, Casing 6: S24, Casing 7: S25(A), Casing 8: S25(B), Casing 9: S26, Casing 10: S27, Casing 11: S28, Casing 12: S31, Casing 13: S32, Casing 14: S34, Casing 15: S35. Where a typical code is: ①JSG28-14ST28、JSG14ST-S25: JSG=balance type gas water heater 28=nominal heat input(kW) 14=volume ST28=the type of casing, ST=structure platform S25=the type of casing 14~17L balance type & forces exhaust type gas water heater: JSG=balance type gas water heater, JSQ=forces exhaust type gas water, a= nominal heat input(kW) (fixed from 20, 22 to 24), b=volume (fixed from 10, 11 to 12), STc=Sd= the type of casing (c fixed from 27, 28 to 29, d fixed from 21, 25, 22, 21B, 23, 24, 25(A), 25(B), 27, 28, 31, 32, 34 to 35). Same casings as above but without casing 9. ②JSG14ST-S25(B) 、JSQ28-14ST28 JSG=balance type gas water heater JSQ=forces exhaust type gas water 14=volume 28=nominal heat input(kW) ST=structure platform S25(B)=the type of casing, ST28=the type of casing 22~26L outdoor type gas water heater: JSW=outdoor type gas water heater, a= nominal heat input(kW) (fixed from 44 to 52), b=volume (fixed from 22 to 26), ST58=Wd= the type of casing (d fixed from 81, 82, 83 to 84), Casing 1: ST58, W81, Casing 2: W82, Casing 3: W83, Casing 4: W84. ③JSW44-22ST58、 JSW22HT-W81: JSW=outdoor type gas water heater 44=nominal heat input(kW) 22=volume ST58=the type of casing, HT=structure platform W81=the type of casing
JSG20-10ST27, JSG10ST-S21, JSQ20-10ST27, JSQ10ST-S21, JSG22-11ST27, JSG11ST-S21, JSQ22-11ST27, JSQ11ST-S21, JSG24-12ST27, JSG12ST-S21, JSQ24-12ST27, JSQ12ST-S21, JSG20-10ST28, JSG10ST-S25, JSQ20-10ST28, JSQ10ST-S25, JSG22-11ST28, JSG11ST-S25, JSQ22-11ST28, JSQ11ST-S25, JSG24-12ST28, JSG12ST-S25, JSQ24-12ST28, JSQ12ST-S25, JSG20-10ST29, JSG10ST-S22, JSQ20-10ST29, JSQ10ST-S22, JSG22-11ST29, JSG11ST-S22, JSQ22-11ST29, JSQ11ST-S22, JSG24-12ST29, JSG12ST-S22, JSQ24-12ST29, JSQ12ST-S22, JSG10ST-S21B, JSQ10ST-S21B, JSG11ST-S21B, JSQ11ST-S21B, JSG12ST-S21B, JSQ12ST-S21B, JSG10ST-S23, JSQ10ST-S23, JSG11ST-S23, JSQ11ST-S23, JSG12ST-S23, JSQ12ST-S23, JSG10ST-S24, JSQ10ST-S24, JSG11ST-S24, JSQ11ST-S24, JSG12ST-S24, JSQ12ST-S24, JSG10ST-S25(A), JSQ10ST-S25(A), JSG11ST-S25(A), JSQ11ST-S25(A), JSG12ST-S25(A), JSQ12ST-S25(A), JSG10ST-S25(B), JSQ10ST-S25(B), JSG11ST-S25(B), JSQ11ST-S25(B), JSG12ST-S25(B), JSQ12ST-S25(B), JSG10ST-S26, JSQ10ST-S26, JSG12ST-S26, JSQ12ST-S26, JSG10ST-S27, JSQ10ST-S27, JSG12ST-S27, JSQ12ST-S27, JSG10ST-S28, JSQ10ST-S28, JSG12ST-S28, JSQ12ST-S28, JSG10ST-S31, JSQ10ST-S31, JSG12ST-S31, JSQ12ST-S31, JSG10ST-S32, JSQ10ST-S32, JSG12ST-S32, JSQ12ST-S32, JSG10ST-S34, JSQ10ST-S34, JSG12ST-S34, JSQ12ST-S34, JSG10ST-S35, JSQ10ST-S35, JSG11ST-S35, JSQ11ST-S35, JSG12ST-S35, JSQ12ST-S35. JSG28-14ST27, JSG14ST-S21, JSQ28-14ST27, JSQ14ST-S21, JSG30-16ST27, JSG16ST-S21, JSQ30-16ST27, JSQ16ST-S21, JSG31-17ST27, JSG17ST-S21, JSQ31-17ST27, JSQ17ST-S21, JSG28-14ST28, JSG14ST-S25, JSQ28-14ST28, JSQ14ST-S25, JSG30-16ST28, JSG16ST-S25, JSQ30-16ST28, JSQ16ST-S25, JSG31-17ST28, JSG17ST-S25, JSQ31-17ST28, JSQ17ST-S25, JSG28-14ST29, JSG14ST-S22, JSQ28-14ST29, JSQ14ST-S22, JSG30-16ST29, JSG16ST-S22, JSQ30-16ST29, JSQ16ST-S22, JSG31-17ST29, JSG17ST-S22, JSQ31-17ST29, JSQ17ST-S22, JSG14ST-S21B, JSQ14ST-S21B, JSG16ST-S21B, JSQ16ST-S21B, JSG17ST-S21B, JSQ17ST-S21B, JSG14ST-S23, JSQ14ST-S23, JSG16ST-S23, JSQ16ST-S23, JSG17ST-S23, JSQ17ST-S23, JSG14ST-S24, JSQ14ST-S24, JSG16ST-S24, JSQ16ST-S24, JSG17ST-S24, JSQ17ST-S24, JSG14ST-S25(A), JSQ14ST-S25(A), JSG16ST-S25(A), JSQ16ST-S25(A), JSG17ST-S25(A), JSQ17ST-S25(A), JSG14ST-S25(B), JSQ14ST-S25(B), JSG16ST-S25(B), JSQ16ST-S25(B), JSG17ST-S25(B), JSQ17ST-S25(B), JSG14ST-S27, JSQ14ST-S27, JSG16ST-S27, JSQ16ST-S27, JSG14ST-S28, JSQ14ST-S28, JSG16ST-S28, JSQ16ST-S28, JSG14ST-S31, JSQ14ST-S31, JSG16ST-S31, JSQ16ST-S31, JSG14ST-S32, JSQ14ST-S32, JSG16ST-S32, JSQ16ST-S32, JSG14ST-S34, JSQ14ST-S34, JSG16ST-S34, JSQ16ST-S34, JSG14ST-S35, JSQ14ST-S35,JSG16ST-S35, JSQ16ST-S35. JSW44-22ST58, JSW22HT-W81, JSW52-26ST58, JSW26HT-W81, JSW22HT-W82, JSW26HT-W82, JSW22HT-W83, JSW26HT-W83, JSW22HT-W84, JSW26HT-W84.

Approval Holder:
Guangdong Vanward New Electric Co. Ltd.
Company Name
Guangdong Vanward New Electric Co. Ltd.
Address
13 Jianye Mid- Road Shunde High Tech Industry Development Zone
Country
Ronggui Shunde

View All Listings by this Company
Manufacturer:
Guangdong Vanward New Electric Co. Ltd.
Company Name
Guangdong Vanward New Electric Co. Ltd.
Address
13 Jianye Mid- Road Shunde High Tech Industry Development Zone
Country
Ronggui Shunde

View All Listings by this Company

Print This Approval


#240904726

‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240904726
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
22mm compression (Primary Circuit) 15mm compression (Secondary Circuit)
Marking:
E.C.A. on front cover. E.C.A, model and technical information including KW rating on adhesive label on body.
Installation Requirements:
R001 R360
Expiry date:
30/09/2029
Model:
8116350010 CALORA PREMIX 24 HM ERP UK 8116484110 CALORA PREMIX 14 HM ERP UK 8116487110 CALORA PREMIX 20 HM ERP UK 8116356010 CALORA PREMIX 28 HM ERP UK 8116389010 CITIUS PREMIX 14 HM ERP UK 8116392010 CITIUS PREMIX 20 HM ERP UK 8116353010 CITIUS PREMIX 24 HM ERP UK 8116380010 CITIUS PREMIX 28 HM ERP UK 8116576110 Proteus Premix 42 HM DG ERP UK 8116550010 Proteus Premix 45 HM DG ERP UK

Approval Holder:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company

Print This Approval


#241104709

Range of indirect heat interface units (HIU) providing heating and instantaneous hot water. The central heating and hot water is generated via plate heat exchangers. Maximum operating pressure 10 bar (primary and DHW secondary). Maximum operating pressure 2.5 bar CH secondary Maximum operating temperature 90°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
241104709
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
22mm compression
Marking:
Bosch on front panel and technical info on adhesive label.
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2029
Model:
7-735-600-739 - Flow 8500 40, 7-735-600-740 - Flow 8500 40 H, 7-735-600-741 - Flow 8500 50, 7-735-600-742 - Flow 8500 50 H, 7-735-600-743 - Flow 8500 60, 7-735-600-744 - Flow 8500 60 H.

Approval Holder:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Danesmoor Works Pilsley Clay Cross Chesterfield Derbyshire
Postcode
S45 9BY

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 5 of 6

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.