Two-hole, single outlet (fixed) combination tap assembly, (chrome plated brass body), incorporating quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, handset & metal back nuts. Maximum working pressure: 10.0 bar Maximum operating temperature 60°C
Two-hole, single outlet (fixed) combination tap assembly (brass bodies – various finishes) incorporating a quarter turn ceramic disc headwork with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The inlets incorporate a stainless strainer and an approved single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10 bar. Maximum operating temperature 65 °C
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a quarter turn ceramic disc headwork with single lever operating members (except 5102-224 with cross top) and a self cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator.
Range of wall mounted, two hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating ceramic cartridge headworks, dome type operating member and an self-cancelling to the shower outlet. The temperature is controlled independently via a thermostatic cartridge, with manual override button. The spout outlets incorporate plastic aerators and the inlets incorporating stainless steel strainers. Both inlets and shower outlet incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Shower hose and handset are not supplied with products. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating ceramic cartridge headworks, single lever operating member and an self-cancelling to the shower outlet. The spout outlets incorporate plastic aerators. Shower outlets incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Shower hose and handset are not supplied with products. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes). Incorporating ceramic cartridge headworks with single lever operating members and a self-cancelling to the shower outlet. The spout outlets incorporate plastic aerators. Shower outlets incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Shower hose and handset are not supplied with products. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Wall mounted, three-hole, single outlet (fixed) combination tap assembly (brass bodies – various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with a click type pop-up waste (verified by test). Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted spout outlets (brass bodies – various finishes) incorporating NBR O-rings and plastic aerators. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C
Wall mounted spout outlet with a brass body (various finishes) incorporating a plastic aerator. Maximum operating temperature 65°C.
Range of cylindrical or tubular expansion vessels with epoxy coated carbon steel bodies. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Range of expansion vessels with epoxy coated steel bodies and EPDM diaphragms. Maximum working pressure 8.0 or 10.0 bar (please refer to model). Maximum operating temperature 70°C or 100°C (please refer to model).
Fixed filling loop assembly comprising of a lever operated brass spherical valve, an angled non-verifiable double check valve/spherical valve assembly (suitable for backflow protection against fluid category 3), brass adaptors and a copper connecting elbow fitting. Maximum working pressure 10.0 bar. Cold water use only.
In-line water filter and housing with polypropylene body. Maximum working pressure 8.6 bar. Cold water use only.
‘BORPLUS’ range of PP-RCT Socket Fusion fittings used with ‘BORPLUS PP-RCT FASER COMPOSITE STABIL’ pipe. Maximum working pressures at 16.0 Bar @ 23°C and 6.0 Bar @ 85°C.
Range of Reliable press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of Stainless-Steel pipes and fittings. Models OT 100 are manufactured to EN 10217-7, all other models are manufactured to EN 10253-4. Fittings and pipe are connected via welding. Maximum working pressure; OT 100 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 110 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 200 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 201 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 212 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 213 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 214 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 400 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 401 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 410 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar OT 411 DN15 - DN 200 25 Bar, DN200 – DN350 16 Bar Type 37 DN15 – DN125 16 Bar, DN150 10 Bar Type 37M DN15 – DN80 16 Bar, DN100 10 Bar Maximum operating temperature – 99°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.
Page 398 of 582
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.