Directory Search Results

Print List

#2103017

Range of eccentric hemisphere valves incorporating blue epoxy coated carbon steel bodies and discs, EPDM seat and a handwheel operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.

Section:
1530 Miscellaneous Fittings
Size:
DN100 - DN400
Marking:
Company Logo (TVI), size, pressure and flow arrow on body.
Installation Requirements:
R001
Expiry date:
31/03/2026
Model:
PQ347X/F-10C
Product Images

Approval Holder:
Tiangjin Tanggu No.1 valve Co, Ltd.
Company Name
Tiangjin Tanggu No.1 valve Co, Ltd.
Address

View All Listings by this Company
Manufacturer:
Tiangjin Tanggu No.1 valve Co, Ltd.
Company Name
Tiangjin Tanggu No.1 valve Co, Ltd.
Address

View All Listings by this Company

Print This Approval


#2012049

Keraflo range of a servo ceramic valves with DZR brass body. Maximum working pressure 6.0 bar. Cold water use only.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2012049
Size:
20mm, 25mm, 32mm, 40mm, 50mm male BSP inlets.
Marking:
Keraflo on valve body, model and year of manufacture (YYYY) on adhesive label on top of valve. Keraflo, WRAS & serial number on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/12/2025
Model:
SCV20, SCV25, SCV32, SCV40, SCV50.

Approval Holder:
Keraflo Ltd.
Company Name
Keraflo Ltd.
Address
Unit 1 Woodley Park Estate, 59/69 Reading Road, Woodley, Berkshire
Postcode
RG5 3AN
Phone
0118 9219920

View All Listings by this Company
Manufacturer:
Keraflo Ltd.
Company Name
Keraflo Ltd.
Address
Unit 1 Woodley Park Estate, 59/69 Reading Road, Woodley, Berkshire
Postcode
RG5 3AN
Phone
0118 9219920

View All Listings by this Company

Print This Approval


#2104001

Wall mounted outlet with detachable shower hose connector (42037UK model) and wall mounted shower outlet (42018UK model). The 42018UK model is supplied with an optional, detachable shower hose connector assembly which incorporates an integral plastic flow regulator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model 42037UK has a maximum operating temperature of 80°C. Model 42018UK has a maximum operating temperature of 60°C.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2104001
Size:
½” BSP (M) inlet/outlet.
Marking:
42037UK: Galvincare on body. 42018UK: Galvin Engineering logo (letters ‘GE’ within an oval) on shower outlet face.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
42037UK: ‘CP Galvincare Mental Health Anti-Ligature Shower Outlet Wall Connection’. 42018UK ‘Galvincare CP-BS Mental Health Anti-Ligature Safe Connect Shower Head’.
Product Images

Approval Holder:
Galvin Engineering
Company Name
Galvin Engineering
Address
410 Victoria Road Malaga WA 6090
Country
Australia

View All Listings by this Company
Manufacturer:
Galvin Engineering
Company Name
Galvin Engineering
Address
410 Victoria Road Malaga WA 6090
Country
Australia

View All Listings by this Company

Print This Approval


#2010071

Range of booster sets with a stainless steel manifold system connecting 2 or 3 wholesome water pumps (For 2HELIX & 3HELIX models only). The set also includes spherical valves, and a non-return valve Maximum working pressure: 10.0 Bar Maximum operating temperature: 40°C

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2010071
Size:
1 ¼” BSP (F) on 1 HELIX (Centrum SV) or 2 ½” BSP (M) on 2HELIX (CENTRUM DV) and 3HELIX (CENTRUM TV).
Marking:
Wilo logo (see notes), model, PN, max temp, manufacturer and other technical info on adhesive label on pump body.
Installation Requirements:
R001 R415
Expiry date:
31/10/2025
Model:
Wilo Model Codes: Wilo CENTRUM SV406, Wilo CENTRUM SV408, Wilo CENTRUM SV605, Wilo CENTRUM SV608, Wilo CENTRUM SV1004, Wilo CENTRUM SV1006, Wilo CENTRUM DV406, Wilo CENTRUM DV408, Wilo CENTRUM DV605, Wilo CENTRUM DV608, Wilo CENTRUM DV1004, Wilo CENTRUM DV1006, Wilo CENTRUM TV406, Wilo CENTRUM TV408, Wilo CENTRUM TV605, Wilo CENTRUM TV608, Wilo CENTRUM TV1004, Wilo CENTRUM TV1006.
Product Images

Approval Holder:
Wilo UK
Company Name
Wilo UK
Address
Second Avenue Centrum 100 Burton on Trent
Postcode
DE14 2WJ
Country
Staffordshire

View All Listings by this Company
Manufacturer:
Wilo UK
Company Name
Wilo UK
Address
Second Avenue Centrum 100 Burton on Trent
Postcode
DE14 2WJ
Country
Staffordshire

View All Listings by this Company

Print This Approval


#2012926

Range of single stage centrifugal pumps with bronze housings or plastic housings (see model) and plastic impellers. Maximum working pressure 6.0 bar (UP(S)(O) 15-XX CES87 130 model only), 10.0 bar (all other models). Maximum operating temperature 95°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2012926
Size:
1” BSP (M) inlet/outlet.
Marking:
Grundfos, Grundfos logo, type, model, production no. and other technical information on data plate on top of motor. Flow arrow on body.
Installation Requirements:
R001 R008
Expiry date:
31/12/2025
Model:
Bronze pump housing: UP(S)(O) 15-XX B 130 (GFSxx). SOLAR 15-XX B 130 (GFSxx). Plastic (composite) pump housing: UP(S)(O) 15-XX CIL2 (GFSxx). SOLAR 15-XX CIL2 (GFSxx). UP(S)(O) 15-XX CES87 (GFSxx). Where: UP or SOLAR = Range name. S = Pumps equipped with electronic speed control. O = High efficiency pump. 15 = 1” BSP connections. XX = Maximum Head (dm). B = Pump housing - Bronze. CES87 or CIL2 = Pump housing - Composite. 130 (where noted) = Port length (mm).
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 304 of 2216

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.