#2110310

Deck mounted single hole, single outlet (fixed) electronically controlled tap assembly (chromium plated brass). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Tempearture is controlled from a separate control unit incorporating a thermostatic cartridge, which is operated by a single lever on the side of the unit. The spout connects to the unit via a (transparent) PEX-b pipe. The inlets of the control unit incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the unit incorporates a plastic flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
2110310
Size:
½” BSP (M) (to control unit).
Marking:
Toto on spout. Toto and model on adhesive label on control unit.
Installation Requirements:
R001 R006 R007 R010
Expiry date:
31/10/2026
Model:
TLP01701G (Spout with IR sensor) TLP01702E1 (Control unit with thermostatic mixer)
Product Images

Approval Holder:
TOTO Europe GmbH
Company Name
TOTO Europe GmbH
Address
Zollhof 2 40211 Düsseldorf Germany
Phone
+49 211 273080

View All Listings by this Company

Print This Approval


#2109024

BS1212-4 (2016) compact type float operated valve for WC flushing cisterns, side entry type. The inlet incorporates a plastic flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
2109024
Size:
½” BSP (M) 3/8” BSP (M)
Marking:
RONGJI (brand of manufacturer), BS1212-4, datum level & model on body
Installation Requirements:
R001 R550
Expiry date:
30/09/2026
Model:
A1200
Product Images

Approval Holder:
Xiamen R&J Precision Technology Co., Ltd.
Company Name
Xiamen R&J Precision Technology Co., Ltd.
Address

View All Listings by this Company
Manufacturer:
Xiamen R&J Precision Technology Co., Ltd.
Company Name
Xiamen R&J Precision Technology Co., Ltd.
Address

View All Listings by this Company

Print This Approval


#2109022

Range of WC flushing cisterns incorporating a BS 1212-4 (2016) side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres or 4.5/3 litre flush volumes. The cistern is operated by a manual push button and the product incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2109022
Size:
15mm Compression Model added April 2022: ½” BSP (M)
Marking:
Fluidmaster, model and flushing volumes inside of cistern. Olympia on operating buttons. Model added April 2022: Fluidmaster, model and flushing volumes inside of cistern.
Installation Requirements:
R001 R556
Expiry date:
30/09/2026
Model:
T02-0100WRAS1, T02-0100WRAS2 & T02-0100WRAS3. Model added April 2022: T02-0800WRAS3
Product Images

Approval Holder:
Fluidmaster, Inc.
Company Name
Fluidmaster, Inc.
Address
30800 Rancho Viejo Road San Juan Capistrano
Postcode
CA 92675
Country
United States
Phone
1-949-796-2653
General Email
jloera@fluidmaster.com

View All Listings by this Company
Manufacturer:
Fluidmaster, Inc.
Company Name
Fluidmaster, Inc.
Address
30800 Rancho Viejo Road San Juan Capistrano
Postcode
CA 92675
Country
United States
Phone
1-949-796-2653
General Email
jloera@fluidmaster.com

View All Listings by this Company

Print This Approval


#2110097

WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2110097
Size:
½” BSP (M)
Marking:
Fluidmaster on cistern. Schwab brandname on operating button.
Installation Requirements:
R001 R556
Expiry date:
31/10/2026
Model:
5-474-025 UP FRONT-TOP 187 - 747 (cistern only). 5-398-070 DUPLO WC 187 83 cm 747 FV (cistern with frame).
Product Images

Approval Holder:
Fluidmaster, Inc.
Company Name
Fluidmaster, Inc.
Address
30800 Rancho Viejo Road San Juan Capistrano
Postcode
CA 92675
Country
United States
Phone
1-949-796-2653
General Email
jloera@fluidmaster.com

View All Listings by this Company
Manufacturer:
Fluidmaster, Inc.
Company Name
Fluidmaster, Inc.
Address
30800 Rancho Viejo Road San Juan Capistrano
Postcode
CA 92675
Country
United States
Phone
1-949-796-2653
General Email
jloera@fluidmaster.com

View All Listings by this Company

Print This Approval


#2106003

Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2106003
Size:
1/2” BSP (M).
Marking:
Fluidmaster and model number inside cistern.
Installation Requirements:
R001 R556
Expiry date:
30/06/2026
Model:
T06-0800WRAS2 3-4.5 Ltr. T06-0800WRAS1 3-4.5 Ltr. T06-0100WRAS1 3-6Ltr. T06-0100WRAS2 3-6Ltr.

Approval Holder:
Fluidmaster, Inc.
Company Name
Fluidmaster, Inc.
Address
30800 Rancho Viejo Road San Juan Capistrano
Postcode
CA 92675
Country
United States
Phone
1-949-796-2653
General Email
jloera@fluidmaster.com

View All Listings by this Company
Manufacturer:
Fluidmaster, Inc.
Company Name
Fluidmaster, Inc.
Address
30800 Rancho Viejo Road San Juan Capistrano
Postcode
CA 92675
Country
United States
Phone
1-949-796-2653
General Email
jloera@fluidmaster.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 284 of 1706

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.