Directory Search Results

Print List

#2202702

Center Brand range of brass and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.

Section:
1210 Fittings for use with Tube and Pipe
Section Subtitle:
End feed, for use with copper tube. Unless specified in the individual approval, the products within this section are not suitable for below ground use
WRAS Approval Number:
2202702
Marking:
CB (brand of Wolseley) and size on body
Installation Requirements:
R001
Expiry date:
28/02/2027
Model:
Center Brand range consisting of: N1 STRAIGHT COUPLING: 6mm to 54mm N1IM ADAPTOR COUPLING: 15mm x ½” to 28mm x 1” N1R REDUCING COUPLING: 8mm x 6mm to 54mm x 42mm N1SLIP STRAIGHT COUPLING SLIP: 15mm to 54mm N2 STRAIGHT FEMALE CONNECTOR: 15mm x 3/8" to 54mm x 2” N3 STRAIGHT MALE CONNECTOR: 15mm x 3/8" to 54mm x 2” N6 REDUCER: 8mm x 6mm to 54mm x 42mm N7 FEMALE ADAPTOR: 15mm x ½” to 54mm x 2” N8 MALE ADAPTOR: 15mm x ½” to 54mm x 2” N9 ADAPTOR: ½” x 15mm to ¾” x 22mm N11 UNION COUPLING CONE FACE: 15mm to 54mm N12 ELBOW: 8mm to 54mm N12R REDUCING ELBOW: 22mm x 15mm N12S STREET ELBOW: 10mm to 54mm N13 MALE ELBOW: 15mm x 1/2” to 28mm x 1” N14 FEMALE ELBOW: 15mm x ½” to 35mm x 1.1/4” N15 BACKPLATE ELBOW: 15mm x ½” to 22mm x ¾” N18 SLOW BEND: 10mm to 54mm N18S SLOW STREET BEND: 10mm to 54mm N21 OBTUSE ELBOW 45°: 12mm to 54mm N21S OBTUSE STREET ELBOW 45°: 15mm to 54mm N22 PARTIAL CROSSOVER: 15mm to 22mm N23 FULL CROSSOVER: 15mm to 22mm N24 EQUAL TEE: 6mm to 54mm N25 TEE REDUCED BRANCH: 15mm x 15mm x 10mm to 54mm x 54mm x 42mm N26 TEE ONE END REDUCED: 18mm x 15mm x 18mm to 54mm x 42mm x 54mm N27 TEE ONE END AND BRANCH REDUCED: 15mm x 12mm x 12mm to 54mm x 42mm x 42mm N28 TEE BOTH ENDS REDUCED: 10mm x 10mm x 12mm to 35mm x 35mm x 42mm N29 FEMALE TEE: 15mm x ½” x 15mm N29R FEMALE TEE: 22mm x ½” x 22mm to 28mm x ½” x 28mm N30 FEMALE TEE: 15mm x 15mm x ½” to 28mm x 28mm x 1” N30R FEMALE TEE: 22mm x 22mm x ½” to 35mm x 35mm x ½” N50 CROSS: 15mm to 22mm N61: 8mm to 54mm N61AV STOP END: 15mm N62 STRAIGHT TAP CONNECTOR: 15mm x ½” to 22mm x ¾” N63 BENT TAP CONNECTOR: 15mm x ½” to 22mm x ¾” N64 BENT UNION ADAPTOR: 15mm x ¾” N65 BENT MALE UNION CONNECTOR: 15mm x ½” to 28mm x 1” N68 STRAIGHT UNION ADAPTOR: 15mm x ¾” to 28mm x 1¼” N68FF FLAT FACED UNION ADAPTOR: 22mm x ¾” N68 METER UNION: 22mm x ¾” N69 STRAIGHT MALE UNION CONNECTOR: 15mm x ½” to 54mm x 2”

Approval Holder:
Wolseley UK
Company Name
Wolseley UK
Address
2 Kingmaker Court Warwick Technology Park Warwick
Postcode
CV34 6DY
Country
United Kingdom
Phone
01926705792
General Email
martin.lister@wolseley.co.uk

View All Listings by this Company

Print This Approval


#2201339

Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.

Section:
1350 Heat Exchangers
Size:
Secondary: 1½” BSP (F) or 2” BSP (F), as well as 1” BSP (F) recirculation connection where fitted. Primary: DN40 or DN50 flanged inlet, 1½” BSP (M) or 2” BSP (M) outlet.
Marking:
Stokvis logo, Stokvis, Econoplate & model, pressure, flow rate, WRAS and other technical information on data plate on body.
Installation Requirements:
R001 R511
Expiry date:
31/01/2027
Model:
Econoplate models: Following models xx goes from 5-59 to denote number of plates. E4Axx, E4Aixx, E4Bxx, E4Bixx, E3A1xx, E3Ai1xx, C3Ai1xx, E3A3xx, E3Ai3xx, C3Ai3xx, i2Axx, i2Bxx, E2A(##)xx, E2B(##)xx, E4AxxD, E4AixxD, E4BxxD, E4BixxD, E3A1xxD, E3Ai1xxD, C3Ai1xxD, E3A3xxD, E3Ai3xxD, C3Ai3xxD, i2AxxD, i2BxxD. Following models xx goes from 11-74 to denote number of plates: E3Cxx, E3Cixx, C3Cixx, i2Cxx, E2C(##)xx, E3CxxD, E3CixxD, C3CixxD, i2CxxD. FIRST LETTER: E = MODELS PAINTED YELLOW. C = MODELS ARE IDENTICAL TO E MODELS BUT PAINTED WHITE. i = Fitted with a speed controlled primary pump (2 port models only). FIRST NUMBER: PRIMARY CONTROL VALVE TYPE/NO. OF PORTS - 2, 3 or 4. NEXT LETTER RELATES TO FRAME SIZE OR PRIMARY CONTROL SET (PUMP & OR CONTROL VALVE) SIZE: Frame size - A, B or C. When fitted with a speed controlled primary pump add an i (3 and 4 port models only). When fitted with twin head primary pump add a D to model designation after the number xx. xx = number of (heat exchanger) plates All model names are followed by +0R where: +0R = no secondary pump. ## added to differentiate primary fluids and can be replaced with the following: SW = steam to water. LTHWS = low temperature heating to domestic hot water. MTHWS = medium temperature heating to domestic hot water. Units with a secondary pressure of 10.0 bar use stainless connections and are denoted by ’10 bar’ at end of model number. Units with a secondary pressure of 6.0 bar use bronze connections which are standard fitment so no addition or alteration to model number. All models can be fitted with either 1.5” or 2” secondary circuit connections, this does not affect the product model number. Models added February 2023 - Econoplate STP3, STC3, STP2, STC2 & STP4: ST (first 2 figures) – Signifies a Stokvis product on all models. All Econoplate models are orange in colour. P or C (3rd figure) – Signifies small or large chassis (P = 1.5” primary connections, C = 2” primary connections). 2, 3, or 4 (4th figure) – Signifies configuration of chassis to suit control valve, 2, 3 or 4 port. A, B, or C (5th figure) – Signifies secondary connection sizes (A = 1.5”, B = 2.0”, C = 2.0” stainless). 5 – 59 (P chassis), 11 – 74 (C chassis) (6th & 7th figure) – Signifies number of identical plates on unit. H, L, or M (8th Figure) – Signifies heat exchanger plate design (H = High theta, L = Low theta, M (mixed) = Combination of H & L). T1 or T2 (9th & 10th figure) – Signifies type of control panel (T1 = Standard control panel, T2 = Touchscreen premium panel). 2, 3, or 4 (11th figure) – Signifies primary control valve/s configuration (2 = 2 port, 3 = 3 port, 4 = 4 port). S, D, or N (12th figure) – Signifies primary pump configuration (S = Single head, D = Dual head, N = No primary pump fitted). 1 or 4 (13th figure) – Signifies number of temp sensors fitted to unit (1 = 1, 4 = 4). N (14th Figure) – Signifies no secondary pump fitted. Example: STP3A17HT13S4N
Product Images

Approval Holder:
Stokvis Energy Systems
Company Name
Stokvis Energy Systems
Address
96R Walton Road East Molesey Surrey
Country
KT8 0DL

View All Listings by this Company
Manufacturer:
Stokvis Energy Systems
Company Name
Stokvis Energy Systems
Address
96R Walton Road East Molesey Surrey
Country
KT8 0DL

View All Listings by this Company

Print This Approval


#2203344

Electric instantaneous, vented mains water heater with plastic a housing and silicon rubber hose. Maximum operating temperature 98°C.

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2203344
Size:
½”BSP(M)
Marking:
Ellsi logo, model and product information on body.
Installation Requirements:
R001
Expiry date:
31/03/2027
Model:
PDT-000215
Product Images

Approval Holder:
Ellsi Limited
Company Name
Ellsi Limited
Postcode
DN15 8SL
Country
United Kingdom
General Email
martin@ellsi.co.uk

View All Listings by this Company

Print This Approval


#2111024

OMEG range of wall mounted, near-boiling water dispensers (cased and insulated). The products incorporate a solenoid valve which controls the flow, a stainless-steel tank, 3 or 5L (see model), and a plastic strainer at the inlet. Maximum supply pressure 10.0 bar. Cold water supply only. Maximum operating temperature 95˚C

Section:
1380 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, closed outlet. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within with system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111024
Size:
¾” BSP (M) inlet.
Marking:
HYCO on front of unit. HYCO & OMEG on technical label.
Installation Requirements:
R001 R040
Expiry date:
30/11/2026
Model:
OMEG3 and OMEG5
Product Images

Approval Holder:
Hyco Manufacturing Ltd
Company Name
Hyco Manufacturing Ltd
Address
California Drive, Castleford, West Yorkshire
Postcode
WF10 5QH

View All Listings by this Company

Print This Approval


#2111377

Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C

Section:
1390 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, open outlet.
WRAS Approval Number:
2111377
Size:
3/8” BSP
Marking:
CLEARWATER on front of heater Model and other tech info on adhesive label on body
Installation Requirements:
R001
Expiry date:
30/11/2026
Model:
2.4L,1500KW: CWT124T CWT024T CWT023T 4L,2300KW: CWT140T
Product Images

Approval Holder:
Clearwater Products Ltd
Company Name
Clearwater Products Ltd
Address
Unit 5603 Shannon Place Tewkesbury Place
Postcode
GL20 8SL

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 210 of 806

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.