#2111349

Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111349
Size:
2 ½” BSP (M)
Marking:
Eco Heating Systems Senator+ on front casing.
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2026
Model:
Senator 400 WW Senator 500 WW
Product Images

Approval Holder:
Eco Heating Systems Groningen BV
Company Name
Eco Heating Systems Groningen BV
Address
Rigaweg 10, Groningen
Postcode
9723 TH
Country
Netherlands
Phone
+31 6 86823847
General Email
h.jans@ecohs.nl

View All Listings by this Company
Manufacturer:
Eco Heating Systems Groningen BV
Company Name
Eco Heating Systems Groningen BV
Address
Rigaweg 10, Groningen
Postcode
9723 TH
Country
Netherlands
Phone
+31 6 86823847
General Email
h.jans@ecohs.nl

View All Listings by this Company

Print This Approval


#2110320

Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2110320
Size:
22mm compression
Marking:
Worcester (brand of Bosch) on front of boiler. Worcester, address, model, serial No. & other tech info on adhesive label on inside of panel.
Installation Requirements:
R001
Expiry date:
31/10/2026
Model:
Greenstar Highflow range comprising of model numbers: 7 731 600 098 (model code: 440CDi ErP). 7 731 600 099 (440CDi ErP). 7 731 600 100 (550CDi ErP). 7 731 600 101 (550CDi ERP).
Product Images

Approval Holder:
Worcester Bosch
Company Name
Worcester Bosch
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
+44 1905 752761
General Email
ian.sharp@uk.bosch.com

View All Listings by this Company
Manufacturer:
Worcester Bosch
Company Name
Worcester Bosch
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
+44 1905 752761
General Email
ian.sharp@uk.bosch.com

View All Listings by this Company

Print This Approval


#2111371

Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111371
Size:
2 ½” BSP (M)
Marking:
Lochinvar on front casing. Lochinvar , model & serial number on adhesive label on body
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2026
Model:
TTW410 & TTW580 FLOOR STANDING GAS FIRED COMBINATION BOILERS

Approval Holder:
Lochinvar Ltd.
Company Name
Lochinvar Ltd.
Address
8 Lombard Way The MXL Centre Banbury
Postcode
OX16 4TJ
Country
Oxon
Phone
+44 (0) 1295 269981
General Email
general@lochinvar.ltd.uk

View All Listings by this Company

Print This Approval


#2112024

Range of ultrasonic water meters with brass bodies incorporating EPDM ‘O’-rings. The inlets incorporate a plastic strainer. The DN15 X 165mm and DN20 X 190mm models incorporate a non-return valve on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Size:
DN15 models: ¾” BSP (M). DN20 model: 1” BSP (M).
Marking:
Badger Meter, size, flow arrow, model name, date of manufacture (MM/YY) and technical information on meter face. Flow arrow and size on body.
Installation Requirements:
R001
Expiry date:
31/12/2026
Model:
E-Series G2® Ultrasonic Meter Range: DN15 X 110 ultrasonic meter, meter body: Eco Brass C69300, DN15 X 114 ultrasonic meter, meter body: Eco Brass C69300, DN15 X 165 ultrasonic meter, meter body: Eco Brass C69300, DN20 X 190 ultrasonic meter, meter body: Eco Brass C69300.
Product Images

Approval Holder:
Badger Meter Inc.
Company Name
Badger Meter Inc.
Address
4545 W Brown Deer Road, Milwaukee WI
Postcode
53223
Country
United States
Phone
+1 414 371 5941
General Email
rschultz@badgermeter.com

View All Listings by this Company
Manufacturer:
Badger Meter Inc.
Company Name
Badger Meter Inc.
Address
4545 W Brown Deer Road, Milwaukee WI
Postcode
53223
Country
United States
Phone
+1 414 371 5941
General Email
rschultz@badgermeter.com

View All Listings by this Company

Print This Approval


#2206700

Range of water meters with a brass body, EPDM ‘O’-rings and seal. The products incorporate an internal plastic strainer and an optional combined plastic and stainless-steel strainer on the inlet. Maximum working pressure 16.0 bar. Cold water use only

Section:
1505 Water Meters
Size:
1”, 1½” and 2” BSP (M).
Marking:
Diehl Metering, Altair, made in France and technical information on meter face. Material and flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/06/2027
Model:
ALTAIR V4 DN25 / DN32 / DN40 - Type A2

Approval Holder:
Diehl Metering S.A.S & Diehl Metering Sp. Z o.o.
Company Name
Diehl Metering S.A.S & Diehl Metering Sp. Z o.o.
Country

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 204 of 1240

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.