Directory Search Results

Print List

#250107701

'HYDRO MULTI-E' booster set range consisting of two to four electronically controlled pumps connected in parallel and mounted on a common base frame provided with all necessary fittings. The suction manifold incorporates an isolation valve fitted between it and the individual pumps, and a pressure switch with an isolation valve. The discharge manifold incorporates an isolation valve and a non-return valve (not suitable for backflow protection), which is fitted between it and the individual pumps, it also incorporates a combined isolation and drain valve. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250107701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
2” or 2½” BSPT (M). DN80 or DN100 flanged.
Marking:
Grundfos and Grundfos logo on pumps. Grundfos and Grundfos logo, type, Model, P/N no., Serial no., technical info, manufacturing country on adhesive label on pump base plate.
Installation Requirements:
R001 R415 R511
Expiry date:
31/01/2030
Model:
2” or 2½” BSPT (M): HYDRO MULTI-E “X” CRIE1-* x1 x2-x3-x4-x5-x6. HYDRO MULTI-E “X” CRIE3-* x1 x2-x3-x4-x5-x6. HYDRO MULTI-E “X” CRIE5-* x1 x2-x3-x4-x5-x6. 2½” BSPT (M) or DN80 flanged. HYDRO MULTI-E “X” CRIE10-* x1 x2-x3-x4-x5-x6. DN80 or DN100 flanged. HYDRO MULTI-E “X” CRIE15-* x1 x2-x3-x4-x5-x6. HYDRO MULTI-E “X” CRIE20-* x1 x2-x3-x4-x5-x6. The “X” preceding CR indicates the number of pumps in the booster set, between 2 and 4 pumps. CRIE1, CRIE3 and CRIE5 pumps: • Systems with 2 to 3 pumps = 2” threaded. • Systems with 4 pumps = 2½” threaded. CRIE10 pumps: • Systems with 2 pumps = 2½” threaded. • Systems with 3 to 4 pumps = DN80 flanges. CRIE15 and CRIE20 pumps: • Systems with 2 pumps = DN80 flanges. • Systems with 3 to 4 pumps = DN100 flanges. The number following the pump type designation (1, 3, 5, 10, 15 and 20) indicates the flow rate of the pump in m3/h. * The pumps are available with 1 to 36 impellers/stages (e.g. CRIE5-12 = 12 stages). x1 = U1, U2 or U8 relates to supply voltage (of no importance for drinking water). x2 = Design: A, B or C (of no importance for drinking water). x3 = Staring method: A (of no importance for drinking water). x4 = Product (country) range: A: International range. x5 = Material combination: A: Stainless steel manifold and base frame and standard valves. x6 = Options: A: Standard hydraulic.
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#241107701

Self-priming single stage pump, with stainless steel body, plastic impellers, stainless steel shaft, NBR 'O'-rings and seals. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241107701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1” BSP (F).
Marking:
Grundfos and Grundfos logo on body. Grundfos and Grundfos logo, type, model number, product/version number, technical information, serial number and manufacturing location on adhesive label on motor housing.
Installation Requirements:
R001 R008 R415
Expiry date:
30/11/2029
Model:
99458789: JP 4-54 1X230V 50Hz 1,5M UK HU IE2.
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#241204714

Dutypoint ‘VMV’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. VMV2, VMV3 and VMV4 pump sets are available with DN80 to DN150 manifolds depending on application. VMV5, VMV6, VMV7 and VMV8 pump sets are available with DN150 to DN200 manifolds, depending on application. The products incorporate spherical valves on both the suction and discharge manifolds, with expansion vessels, isolation valves, pressure gauges and transducers on the discharge manifolds only. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241204714
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN80 – DN200 Flanged connection
Marking:
Duty point, model and pressure on data label.
Installation Requirements:
R001 R415
Expiry date:
31/12/2029
Model:
VMV DN80 Versions twin, triple and quadruple pump units: VMV2-05, VMV2-07 and VMV2-10 – All motor sizes VMV3-05, VMV3-07 and VMV3-10 – All motor sizes VMV4-05, VMV4-07 and VMV4-10 – All motor sizes DN100 Versions: Twin, Triple and Quadruple Pump Units: VMV2-05, VMV2-07 and VMV2-10 – All motor sizes VMV3-05, VMV3-07 and VMV3-10 – All motor sizes VMV4-05, VMV4-07 and VMV4-10 – All motor sizes DN150 Versions: Twin, Triple and Quadruple Pump Units: VMV2-05, VMV2-20 and VMV2-25 – All motor sizes VMV3-05, VMV3-20 and VMV3-25 – All motor sizes VMV4-05, VMV4-20 and VMV4-25 – All motor sizes Units incorporating from 5 to 8 pumps (Models VMV5, VMV6, VMV7, VMV8): All units will feature DN150 – DN200 manifolds, size dependent on application. Key to Model Numbers: Example of Model Number: VMV2-15-V110 Range: VMV Number of pumps: 2 Nominal Flow rate (l/sec): 15 Inverter type e.g. ‘V’ for Vasco, or ‘H’ for Hydrovar Motor size (kW x 10)
Product Images

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Unit A, Quedgeley West Business Park, Hardwicke, Gloucester
Postcode
GL2 4PA
Country
United Kingdom
Phone
01452313334
General Email
austin.hill@dutypoint.com

View All Listings by this Company

Print This Approval


#241204019

Range of ceiling mounted shower heads (chrome plated brass bodies). Inlets incorporate plastic flow regulators and single check valve cartridges (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Open outlet use only. Maximum operating temperature 60°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
241204019
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M).
Marking:
Gessi on outlet.
Installation Requirements:
R001 R040
Expiry date:
31/12/2029
Model:
57821+57877 - Headshower (rain + LED), 57801+57871 - Headshower (rain).
Product Images

Manufacturer:
Gessi S.p.A.
Company Name
Gessi S.p.A.
Address
Parco Gessi Hamlet Vintebbio Serravalle Sesia
Postcode
13037
Country
Italy
Phone
+39 0163 454111

View All Listings by this Company

Print This Approval


#2211067

Range of shower handsets with ABS plastic bodies (various finishes, see models). Maximum operating temperature (see models).

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
2211067
Note:
Open outlet use only.
Size:
½” BSP (M).
Marking:
Triton on body.
Installation Requirements:
R001 R040
Expiry date:
30/11/2027
Model:
88500075 - Chromium plated (75°C), 88500106 - Satin Blacked (75°C), 88500082 - Chromium plated (75°C), 88500074 - White coloured (60°C), 88500081 - White coloured (60°C), 88500069 – Satin Chromed (60°C), 88500099 - Satin Blacked (75°C), 88500070 - Chromium plated (75°C), 88500062 - White coloured (60°C), 88500061 - Chromium plated (75°C), 88500060 - White coloured (60°C), 88500068 – Satin Chromed (60°C), 88500083 - Chromium plated (75°C), 88500086 - White coloured (60°C), 88500084 - White coloured (60°C), 88500085 - Chromium plated (75°C). Model added October 2024 88500112 - Chromium plated (60 C).

Approval Holder:
Triton Showers
Company Name
Triton Showers
Address
Triton Road, Nuneaton, Warwickshire
Postcode
CV11 4NR
Country
United Kingdom
Phone
02476 324423
General Email
paulrowley@tritonshowers.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2020 of 2264

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.