#241002090

Range of combined bath filler and/or waste and overflow assemblies (see models) in various finishes. Open outlet use only Maximum operating temperature: 60ºC

Section:
0681 Combination Tap Assemblies
Section Subtitle:
Miscellaneous.
WRAS Approval Number:
241002090
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Stainless steel braided, EPDM lined, flexible hose assembly with a ½” BSP (F) captive nut (Filling Hose) and 1.1/2” BSP (M) (Pop Up Waste)
Marking:
DTC56 on waste body
Installation Requirements:
R001 R576
Expiry date:
31/10/2029
Model:
ZD50010220 ZD50010230 BFW001 BFW001BK

Approval Holder:
Methven UK Limited
Company Name
Methven UK Limited
Address
3-3A Stone Cross Court Yew Tree Way Golborne Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602
General Email
raluca.olariu@uk.methven.com

View All Listings by this Company

Print This Approval


#241202044

Range of tap adaptors with chrome plated (brass or plastic) bodies. The outlet of some models incorporates a plastic flow restrictor. The side mount adaptors (except 90-001801) incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The side mount adaptors (except 90-001804) incorporate a piston type component which is intended to stop the flow to change the filter. All side mount adaptors and 90-001869 & 90-001873 Fixed Position Adaptors have a maximum working pressure of 5.0 bar. All other models are open outlet use only. Maximum operating temperature 60°C.

Section:
0681 Combination Tap Assemblies
Section Subtitle:
Miscellaneous.
WRAS Approval Number:
241202044
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model
Marking:
T safe on body
Installation Requirements:
R001 R040
Expiry date:
31/12/2029
Model:
Connectors: 01-990198 - M21,5/M24F 01-990246 - M24F 01-990247 - M18M to M24F 01-990248 - ½" BSPM to M24F 01-990260 - M16M to M24F 01-990265 - M16M to M24F 01-990267 - M20M to M24F 90-001851 - 15-29mm Jubilee clip Side Mount Adaptors: 90-001801 - M24M/M22 F 90-001804 with flow restrictor - M24M/M22F 90-001805 - M24M/M22F 90-001806 with flow restrictor - M24M/M22F 90-001814 with flow restrictor - M24M 90-001815 - M24M 90-001816 with flow restrictor - M24M 90-001844 with flow restrictor - M24M 90-001854 with flow restrictor - M24M Fixed Position Adaptor: 90-001861 - M24M/M22F 90-001862 - M24M/M22F 90-001864 - M21.5M 90-001865 - M24M 90-001866 - M21.5M 90-001867 - M24M 90-001868 - M24M 90-001869 - M24M 90-001871 - M24M 90-001872 - ½” BSP (F) 90-001873 - ½” BSP (F) 90-001875 - ½” BSP (F)
Product Images

Manufacturer:
T-safe A/S
Company Name
T-safe A/S
Address
Gydevang 1, Alleroed
Postcode
3450
Country
Denmark
Phone
+45 61610518

View All Listings by this Company

Print This Approval


#2211066

Range of exposed bath fillers (brass body, various finishes) incorporating a ceramic cartridge headwork, controlling both flow and temperature with a single lever operating member. The products incorporate integrated overflow and click type pop-up waste systems. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C

Section:
0681 Combination Tap Assemblies
Section Subtitle:
Miscellaneous.
WRAS Approval Number:
2211066
Size:
3/4" BSP (M)
Marking:
Eastbrook Logo on operating member.
Installation Requirements:
R001 R576
Expiry date:
30/11/2027
Model:
98.4001 98.4002 98.4003

Approval Holder:
Eastbrook Company
Company Name
Eastbrook Company
Postcode
GL4 3DB
Country
United Kingdom
General Email
christopher.russell@eastbrookco.com

View All Listings by this Company

Print This Approval


#241202028

Range of swivel or fixed spout outlets (chromium plated brass) incorporating a plastic aerator. Open outlet use only Maximum operating temperature 60.0°C

Section:
0682 Combination Tap Assemblies
Section Subtitle:
Spout outlet(s).
WRAS Approval Number:
241202028
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating 1/2" BSP (F) captive nut end connections.
Marking:
Dornbracht on Spout
Installation Requirements:
R001 R006 R009 R010
Expiry date:
31/12/2029
Model:
13700845 & 13716882
Product Images

Approval Holder:
Dornbracht AG & Co. KG
Company Name
Dornbracht AG & Co. KG
Address
Koebbingser Muehle 6 Iserlohn
Postcode
D-58640
Country
Germany
Phone
+49 2371 433 0
General Email
wpape@dornbracht.com

View All Listings by this Company

Print This Approval


#241202702

Range of expansion vessels with fibreglass bodies and butyl diaphragms. Maximum working pressure: 8.6 Bar. Maximum operating temperature: 23 °C.

Section:
1000 Expansion Vessels
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
see models
Marking:
Global water logo, model, pressure, temperature and other information on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/12/2029
Model:
Product Range: C2Lite CAD Tanks. Model Codes: CUPA-60-8.6 (1” BSP connection. 60L capacity), CUPA-80-8.6 (1” BSP connection. 80L capacity), CUPA-100-8.6 (1” BSP connection. 100L capacity), CUPA-130-8.6 (1 BSP connection. 130L capacity), CUPA-200-8.6 (1 ¼” BSP connection. 200L capacity), CUPA-250-8.6 (1 ¼” BSP connection. 250L capacity), CUPA-300-8.6 (1 ¼” BSP connection. 300L capacity), CUPA-350-8.6 (1 ¼” BSP connection. 350L capacity), CUPA-450-8.6 (1 ¼” BSP connection. 450L capacity).
Product Images

Approval Holder:
Global Water Solutions Ltd.
Company Name
Global Water Solutions Ltd.
Address
5th Floor, 37 Esplanade, St. Helier Jersey The Channel Islands
Postcode
JE1 2TR
Country
United Kingdom
Phone
+886 4 2622 0078
General Email
adam@globalwatersolutions.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2018 of 2221

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.