PSC21.ab-c-d-N-f-g-h-I VEGAPULS C 21
PSC22.ab-c-d- N -f-g-h-I VEGAPULS C 22
PSC23.ab-c-d- N -f-g-h-I VEGAPULS C 23
PS21.ab-c-d- N -f-g-h-I VEGAPULS 21
PS31.ab-c-d- N -f-g-h-I VEGAPULS 31
KEY FOR VEGAPULS C 21
ab = explosion protection, which can be displayed as;
XX without, for Ex-free area (CE, UKCA, RCM, EAC)
VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2)
VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22
SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22
SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22
TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE)
TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE)
WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22
WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22
FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1)
FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1
c = Approved as overfill protection, which can be displayed as;
X without
W with (WHG, VLAREM)
d = Ship approval, which can be displayed as;
X without
S with (CCS, RINA, NK, ABS, DNV GL, LR, BV)
N = Foodstuff / Pharmaceutical certificate, which can be displayed as;
X without
N with (NSF/ANSI/CAN 61)
P with (NIH)
F with (FDA, EG1935/2004)
f = Thread process side / Cable side, which can be displayed as;
G Thread G1½ / G1
N Thread 1½NPT / 1NPT
R Thread R1½ / R1
g = Cable material / Length, which can be displayed as;
A PUR / 5m (approx. 16ft)
B PUR / 10m (approx. 32ft)
H PUR / 15m (appr. 48ft)
J PUR / 20m (appr. 64ft)
C PUR / 25m (approx. 82ft)
D PUR / individually selectable (acc. to CE, RCM, EAC)
D PUR / individually selectable (acc. to c-FM-us, c-CSA-us)
h = Electronics, which can be displayed as;
H Two-wire 4 ... 20 mA/HART
W Four-wire Modbus
S Three-wire SDI12
i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as;
X without
B with
KEY FOR VEGAPULS C 22
ab = Explosion protection, which can be displayed as;
XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC)
VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2)
VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22
SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22
SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22
TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE)
TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE)
WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22
WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22
FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1)
FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignition proof, Class II, III Division 1
c = Approved as overfill protection, which can be displayed as;
X without
W with (WHG, VLAREM)
d = Ship approval, which can be displayed as;
X without
S with (CCS, RINA, NK, ABS, DNV GL, LR, BV)
N = Foodstuff / Pharmaceutical certificate, which can be displayed as:
X without
N with (NSF/ANSI/CAN 61)
P with (NIH)
F with (FDA, EG1935/2004)
f = Process fitting, which can be displayed as;
G Thread G1½
N Thread 1½NPT
R Thread R1½
g = Cable material / length, which can be displayed as;
A PUR / 5m (approx. 16ft)
B PUR / 10m (approx. 32ft)
H PUR / 15m (appr. 48ft)
J PUR / 20m (appr. 64ft)
C PUR / 25m (approx. 82ft)
D PUR / individually selectable (acc. to CE, RCM, EAC)
D PUR / individually selectable (acc. to c-FM-us, c-CSA-us)
h = Electronics, which can be displayed as;
H Two-wire 4 ... 20 mA/HART
W Four-wire Modbus
S Three-wire SDI12
i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as;
X without
B with
KEY FOR VEGAPULS C 23
ab = explosion protection, which can be displayed as;
XX without, for Ex-free area (CE, UKCA, RCM, EAC)
VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2)
VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22
SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22
SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22
TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE)
TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE)
WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22
WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22
FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1)
FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1
c = Approved as overfill protection, which can be displayed as;
X without
W with (WHG, VLAREM)
d = Ship approval, which can be displayed as;
X without
S with (CCS, RINA, NK, ABS, DNV GL, LR, BV)
N = Foodstuff / Pharmaceutical certificate, which can be displayed as;
X without
N with (NSF/ANSI/CAN 61)
P with (NIH)
F with (FDA, EG1935/2004)
f = Thread process side / Cable side, which can be displayed as;
F Thread G1
M Thread 1NPT
Q Thread R1
g = Cable material / length, which can be displayed as;
A PUR / 5m (approx. 16ft)
B PUR / 10m (approx. 32ft)
H PUR / 15m (appr. 48ft)
J PUR / 20m (appr. 64ft)
C PUR / 25m (approx. 82ft)
D PUR / individually selectable (acc. to CE, RCM, EAC)
D PUR / individually selectable (acc. to c-FM-us, c-CSA-us)
h = Electronics, which can be displayed as;
H Two-wire 4 ... 20 mA/HART
W Four-wire Modbus
S Three-wire SDI12
i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as;
X without
B with
KEY FOR VEGAPULS 21 / 31
ab = explosion protection, which can be displayed as;
XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC)
AX without, for Ex-free area (CE, UKCA, RCM)
VC ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2)
SC EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2
TC CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2
WC INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2
c = Approved as overfill protection, which can be displayed as;
X Without
W With (WHG, VLAREM)
d = Ship approval, which can be displayed as;
X Without
S With (CCS, RINA, NK, ABS, DNV GL, LR, BV)
N = Foodstuff/Pharmaceutical certificate, which can be displayed as
X Without
N With (NSF/ANSI/CAN 61)
P With (NIH)
F With (FDA, EG1935/2004)
f = Process fitting, which can be displayed as;
G Thread G1½
N Thread 1½NPT
R Thread R1½
g = Cable entry / connection, which can be displayed as;
M M20x1.5 / Cable gland PA black (ø5-9mm), standard
h = Electronics, which can be displayed as;
H Two-wire 4 ... 20 mA/HART
i = Sensor setting via smartphone and VEGA Tools app
X Without
B With